MARS COMMERCE SOLO-NX Manuale utente

SOLO–NX EXT
COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS
USER MANUAL

SOLO-NX
USER MANUAL
Page 1
Contents
1FOR YOUR SAFETY..............................................................................................................................................3
2INTRODUCTION....................................................................................................................................................4
3SOLO-NX FEATURES AND APPLICATIONS...................................................................................................5
4START UP.................................................................................................................................................................6
5LED INDICATION..................................................................................................................................................7
6CONNECTION DIAGRAM....................................................................................................................................8
7SOLO-NX UNIT MANAGEMENT........................................................................................................................9
8SOLO-NX FUNCTIONS WITH PROGRAMMING INSTRUCTIONS..........................................................10
8.1 WEB SERVER - LOG IN....................................................................................................................................................10
8.2 WEB SERVER –ADDING UNITS TO USER PROFILE .................................................................................................11
8.3 WEB SERVER-UNIT MANAGEMENT............................................................................................................................13
8.4 INTERCOM CONFIGURATION.......................................................................................................................................14
8.5 WIEGAND ACCESS...........................................................................................................................................................16
8.6 CALLER ID ACCESS.........................................................................................................................................................19
8.7 OUTPUTS SETTINGS........................................................................................................................................................20
8.8 SOLO-NX WIEGAND OUTPUT INTEGRATION ...........................................................................................................22
8.9 TIMER-TIMED CONTROLED OUTPUT .........................................................................................................................23
8.10 ADMINISTRATION...........................................................................................................................................................25
8.11 EVENT LOGING ................................................................................................................................................................27
8.12 MISCELLANEOUS ............................................................................................................................................................28
8.13 PIN ACCESS NOTIFICATION FUNCTION.....................................................................................................................29
9WIEGAND INPUT DATA FORMATS ...............................................................................................................31
9.1 WIEGAND 26 BIT, DIFFERENT DATA FORMATS.......................................................................................................32
9.2 WIEGAND 30 BIT, DIFFERENT DATA FORMATS.......................................................................................................33
10 CONTACTS............................................................................................................................................................34

SOLO-NX
USER MANUAL
Page 2
Figures
Figure 1: SOLO-NX: Connection diagram..........................................................................................8
Figure 2: WEB Server-Sign In page ..................................................................................................10
Figure 3: WEB Server-Main page select ADD mode........................................................................11
Figure 4: WEB Server-Main page adding SOLO-NX units..............................................................12
Figure 5: WEB Server-Unit management window............................................................................13
Figure 6: WEB Server-Intercom settings...........................................................................................14
Figure 7: WEB Server-First Wiegand interface support....................................................................16
Figure 8: WEB Server-Wiegand interface support............................................................................17
Figure 9: WEB Server-Adding Wiegand devices with permanent use..............................................18
Figure 10: WEB Server-Adding Wiegand devices with temporary use............................................18
Figure 11: WEB Server-Caller ID Access.........................................................................................19
Figure 12: WEB Server-Output setting..............................................................................................20
Figure 13: WEB Server-Wiegand Output settings.............................................................................22
Figure 14: WEB Server-Timer setting →Day mode. ........................................................................23
Figure 15: WEB Server-Timer setting →Week mode.......................................................................23
Figure 16: WEB Server-Notification numbers ..................................................................................25
Figure 17: WEB Server-Input alarm configuration ...........................................................................25
Figure 18: WEB Server-Log event ....................................................................................................27
Figure 19: WEB Server-Misc ............................................................................................................28
Figure 20: WEB Server-Global enabling of the notificaton function................................................29
Figure 21: WEB Server-Selecting administrator numbers for notification. ......................................30
Figure 22: WEB Server-First Wiegand interface support..................................................................31
Figure 23: WEB Server-Second Wiegand interface support. ............................................................31
Tables
Table 1: Wiegand 26: Mode 0............................................................................................................32
Table 2: Wiegand 26: Mode 1............................................................................................................32
Table 3: Wiegand 26: Mode 2............................................................................................................32
Table 4: Wiegand 26: Mode 3............................................................................................................32
Table 5: Wiegand 30: Mode 0............................................................................................................33
Table 6: Wiegand 30: Mode 1............................................................................................................33
Table 7: Wiegand 30: Mode 2............................................................................................................33
Table 8: Wiegand 30: Mode 3............................................................................................................33

SOLO-NX
USER MANUAL
Page 3
1FOR YOUR SAFETY
SWITCH ON SAFELY
Do not switch the unit on when use of wireless phone is prohibited or when it may cause
interference or danger.
INTERFERENCE
All wireless phones and units may be susceptible to interference, which could affect performance.
SWITCH OFF IN HOSPITALS
Follow any restrictions. Switch the unit off near medical equipment.
SWITCH OFF IN AIRCRAFT
Follow any restrictions. Wireless devices can cause interference in aircraft.
SWITCH OFF WHEN REFUELING
Do not use the unit at a refueling point. Do not use near fuel or chemicals.
SWITCH OFF NEAR BLASTING
Follow any restrictions. Do not use the unit where blasting is in progress.
USE SENSIBLY
Use only in the normal position as explained in the product documentation. Do not touch the
antenna unnecessarily.

SOLO-NX
USER MANUAL
Page 4
2INTRODUCTION
SOLO-NX (SOLO) is a simple GSM intercom communication system designed to ensure low-cost,
simple to install/use, reliable and single box solution for intercom application. It is designed for
unlimited range, wire free GSM intercom, pin code access, caller ID control and Wiegand access
support.
Optional SOLO-NX supports alarm detection, stay-alive messages, credit detection etc…

SOLO-NX
USER MANUAL
Page 5
3SOLO-NX FEATURES AND APPLICATIONS
Features:
Built-in 4 (2G) or 5 (3G) band GSM module
Up-to 4 intercom call button support (5 numbers each)
Caller ID numbers control (up-to 1000 caller ID numbers)
Up to 100 temporary SPIN access codes
Up to 1000 PIN access codes
2 x input Wiegand receiver
2 outputs (relay supported)
Programming with PC via “USB to Mini USB cable” connected to the unit
Programming by WEB server
Programming by SMS commands
Applications:
Single box, wire free intercom solution
Remote gate opener –Caller ID number recognition
Simple (Wiegand) access system

SOLO-NX
USER MANUAL
Page 6
4START UP
SOLO-NX unit accepts a standard GSM SIM cards from any network.
VERY
IMPORTANT
USE A MICRO SIM CARD
WARNING
DO NOT Insert or remove the SIM card while the unit is powered ON!!
IMPORTANT
Before inserting SIM card to unit make sure the PIN code is
removed!!
Insert SIM card in SOLO-NX unit.
Connect power cable to SOLO-NX unit (YOU MUST POWER THE SOLO UNIT WITH
THE POWER SUPPLY IF INCLUDED. Do not power with any other power supply).
Power up the unit.
Wait until LED1 (Blue) starts flashing. This is set in around 30 –45 seconds.
SOLO-NX unit is now ready to operate.
NOTE
SOLO-NX device will “beep” in 15s interval until the device is not in normal
operation.

SOLO-NX
USER MANUAL
Page 7
5LED INDICATION
Blue LED (LED1)
-Indicates the level of the GSM signal from 1 to 5 LED flashes (1 is weak signal, 5 is
excellent signal)
Red LED (LED2)
-GSM module Activity
Yellow LED (LED3)
-Short flashing indicates that the GSM module is ON, but it is not yet connected on the GSM
network. After connection, yellow led is flashing with short pulse (0,5s) ON and a long
pulse OFF (5s).

SOLO-NX
USER MANUAL
Page 8
6CONNECTION DIAGRAM
Before connection the SOLO-NX please take a look at connection diagram.
Figure 1: SOLO-NX: Connection diagram
IMPORTANT
DO NOT USE Power out (12V AUX) for electric lock driving! Use
separate powersourcefor door electric lock!

SOLO-NX
USER MANUAL
Page 9
7SOLO-NX UNIT MANAGEMENT
Unit supports different types of management (programming):
Unit can be programmed directly by USB connection, with the use of configuration software
running on PC (EasySet).
Unit can be programmed remotely by using WEB server access.
Unit can be programmed remotely by SMS commands (Optional).
Altri manuali per SOLO-NX
2
Indice
Altri manuali MARS COMMERCE Sistema di interfono

MARS COMMERCE
MARS COMMERCE SOLO-KP Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-NX Manuale utente

MARS COMMERCE
MARS COMMERCE Ice-40 Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-IDEA Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-NX Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-KP Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-KC Manuale utente

MARS COMMERCE
MARS COMMERCE SOLO-NX EXT Guida rapida

















