MasterPower Beta-20K Manuale utente

PV Grid Tie Inverter
Installation and Operation Manual
Ver 1.9
Beta Three Phase Inverter
Master Battery, S.L.
Master Batery, S.L.
C/ Dehesa Vieja, 2
28052 Madrid, Spain
Tel: +34 918 021 649
Fax: +34 917 750 542
Email: [email protected]
Web: www.masterbattery.es
If you encounter any problem on the inverter please find out the inverter S/N
and contact us we will try to respond to your question ASAP.
For model Beta-20K Beta-25K Beta-30K Beta-33K
Beta-25K-HV Beta-30K-HV Beta-36K-HV Beta-40K-HV
Please adhere to the actual products in case of any discrepancies in this user manual.

Important notes
Product specifications are subject to change without notice. Every attempt has been made to make
this document complete accurate and up-to-date. Individuals reviewing this document and
installers or service personnel are cautioned however that Master Battery reserves the right to
make changes without notice and shall not be responsible for any damages including indirect
incidental or consequential damages caused by reliance on the material presented including but
not limited to omissions typographical errors arithmetical errors or listing errors in the material
provided in this document.
Master Battery accepts no liability for customers' failure to comply with the instructions for correct
installation and will not be held responsible for upstream or downstream systems Master Battery's
equipment has supplied.
The customer is fully liable for any modifications made to the system; therefore any hardware or
software modification manipulation or alteration not expressly agreed with the manufacturer shall
result in the immediate cancellation of the warranty.
Given the countless possible system configurations and installation environments it is essential to
verify adherence to the following:
● There is sufficient space suitable for housing the equipment.
● Airborne noise produced depending on the environment.
● Potential flammability hazards.
Master Battery will not be held liable for defects or malfunctions arising from:
● Improper use of the equipment.
● Deterioration resulting from transportation or particular environmental conditions.
● Performing maintenance incorrectly or not at all.
● Tampering or unsafe repairs.
● Use or installation by unqualified persons.
This product contains lethal voltages and should be installed by qualified electrical or service
personnel having experience with lethal voltages.

Content
2.3 Notice For Use
3. Overview
3.1 Inverter Interface Instructions
3.2 LED Status Indicator Light
3.3 Keypad
3.4 LCD
4. Product handing and storage
4.1 Product handing
4.2 Product storage
3
5
5
5
6
7
7
7
8
8
9
9
10
1. Introduction
2. Safety Instructions
2.1 Safety Symbols
2.2 General Safety Instruction
4
1.2 Packaging List
31.1 Product Description
5. Installation
5.1 Select a Location for the Inverter
5.2 Mounting the Inverter
5.3 Electrical Connections
6. Start and Stop
6.1 Start the Inverter
6.2 Stop the Inverter
11
11
13
15
25
25
25
5.3.2 DC side connection
5.3.3 AC side connection
18
20
5.3.4 Inverter monitoring connection 22
7. General Operation 26
7.1 Interface 26
5.3.1 Protective ground wire connection(PE) 16

.3.
1. Introduction
Figure 1.1 Front view
Figure 1.2 Bottom view
7.3 Setting
7.3.1 Setting Time
7.3.2 Setting Address
7.4 Advanced Info - Technicians Only
7.4.1 Alarm Message
7.4.3 Version NO.
7.4.4 Communication Data
7.4.5 Daily Energy Information
7.5 Advanced Settings - Technicians Only
7.5.1 Select Grid Standard
7.5.2 Grid ON/OFF
8. Maintenance
9. Troubleshooting
10. Specification
29
29
30
32
33
34
35
35
38
38
41
44
44
49
7.4.2 Operational Message 34
7.5.3 Power Setting 41
7.3.3 Language Setting
7.3.4 Screen Brightness Control
30
31
7.3.5 System Update 32
7.4.7 Yearly Energy Detail
7.4.8 Total Energy Detail
7.4.9 Work Log
36
37
37
7.4.6 Monthly Energy Detail 36
7.5.5 Calibrate Energy
42
42
7.5.6 Change Password 43
Content
7.5.4 Clear Energy and Restore factory settings
7.2 Information 28
7.1.1 Main Menu 27
1.1 Product Description
Beta three phase series PV inverters convert direct current (DC) power from the photovoltaic (PV)
array into alternating current (AC) power to satisfy local loads as well as feed the power grid.
There are 8 models for Beta three phase inverter:
Beta-20K Beta-25K Beta-30K Beta-33K Beta-25K-HV Beta-30K-HV Beta-36K-HV
Beta-40K-HV (HV refers to 480V grid voltage)
Content

2. Safety Instructions
.5.
2.1Safety Symbols
Safety symbols used in this manual which highlight potential safety risks and important
safety information are listed as follows:
CAUTION :
CAUTION RISK OF ELECTRIC SHOCK symbol indicates important safety
instructions which if not correctly followed could result in electric shock.
CAUTION:
CAUTION HOT SURFACE symbol indicates safety instructions which if not
correctly followed could result in burns.
NOTE:
NOTE symbol indicates important safety instructions which if not correctly
followed could result in some damage or the destruction of the inverter.
WARNING:
WARNING symbol indicates important safety instructions which if not correctly
followed could result in serious injury or death.
Improper use may result in potential electric shock hazards or burns. This manual contains
important instructions that should be followed during installation and maintenance. Please
read these instructions carefully before use and keep them for future reference.
2.2 General Safety Instructions
WARNING:
Electrical installations must be done in accordance with the local and national
regulatory and electrical safety standards.
WARNING:
DC input and AC output must be electrically isolated before operation.
DO NOT connect PV array positive (+) or negative (-) to the ground. To do
so may cause serious damage to the inverter.
.4.
1.2 Packaging List
Please check according to following table to see whether all the parts were included in the
packaging:
Adhesive tape set
Table 1.1 Material list
1. Introduction
1
2
3
4
5
6
7
1
1
2
1
Grounding M4 screw and washer
8
1
1
Ver 1.9
42
3
1
56 8
7
PV Grid Tie Inverter
Installation and Operation Manual
Beta Three Phase Inverter
Master Battery, S.L.
For model Beta-20K Beta-25K Beta-30K Beta-33K
Beta-25K-HV Beta-30K-HV Beta-36K-HV Beta-40K-HV

3. Overview
.6. .7.
3.1 Inverter Interface Instructions
Figure 3.1 Front Panel Display
3.2 LED Status Indicator Lights
There are three LED status indicator lights on the front panel of the inverter.
On the Left: POWER LED indicates the power status of the inverter.
On the Middle: OPERATION LED (green) indicates the operation status.
On the Right: ALARM LED (yellow) indicates the alarm status.
Please see Table 3.1 for details
2. The inverter must be connected to a separate grounded AC group to which no
other electrical equipment is connected
3. The electrical installation must meet all the applicable regulations and standards.
4. The inverter must be installed according to the instructions stated in this
manual.
5. The inverter must be installed according to the correct technical specifications.
2.3 Notice For Use
WARNING:
To reduce the risk of fire over-current protective devices (OCPD) are required
for circuits connected to the Inverter. The recommended rated trip current of
OCPD Beta-20K should be 40A Beta-25K Beta-30K Beta-25K-HV
Beta-30K-HV Beta-36K-HV and Beta-40K-HV should be 63A.
CAUTION:
Risk of electric shock. Do not remove cover. Refer maintenance servicing to
qualified and accredited service technician.
CAUTION:
The PV array (Solar panels) supplies a DC voltage when it is exposed to light.
CAUTION:
Risk of electric shock from energy stored in capacitors of the Inverter. Do not
remove cover until 5 minutes after disconnecting all sources of supply. Service
technician only. Warranty may be voided if any unauthorized removal of cover.
CAUTION:
The surface temperature of the inverter can exceed 75 (167F).℃
To avoid risk of burns DO NOT touch the surface when inverter is operating.
The inverter must be installed out of reach of children.
1. Secure inverter installation is required.
6. To startup the inverter the Grid Supply Main Switch (AC) must be switched on before
the solar panel's DC isolator switched on. To stop the inverter the Grid Supply Main
Switch (AC) must be switched off before the solar panel's DC isolator switched off.
7. DC input voltage of inverter must less than its maximum input voltage of inverter.
2. Safety Instructions

4. Product handing and storage
.8. .9.
3.3 Keypad
3.4 LCD
Scrolling through the displayed options (the Up and the Down keys).
The 7” Liquid Crystal Display (LCD) is located at the front panel of the Inverter
which displays the following information:
1. Inverter operation status and data;
2. Service messages for operator;
3. Alarm messages and fault indications.
POWER
OPERATION
ALARM
Access to modify the adjustable settings (the ESC and the ENTER keys).
3. Overview
Table 3.1 Status indicator
Figure 4.2 Inverter handles
4.1 Product handing
! "
"
There and ENTER keys. The are four keys in the front panel of the Inverter (from left to right):
ESC, UP, DOWN and ENTER keys. The keypad is used for:
Figure 4.1 move the inverter

Figure 5.1 Recommended installation position
4. Installation
Use the original box to repackage the inverter seal with adhesive tape with the desiccant
inside the box.
5. Installation
.11.
.10.
4.2 Product storage 5.1 Select a Location for the Inverter
mm
mm

5.2 Mounting the Inverter
The inverter can be mounted to the wall or metal strut of module. The mounting holes
should be consistent with the size of the bracket or the dimensions shows below.
1. According to the figure 5.2 select the mounting height of the bracket and mark the
mounting holes. For brick walls the position of the holes should be suitable for the
expansion bolts.
2.MAKE SURE the bracket is horizontal and the mounting holes A B and C (in
Figure 5.3) are in the correct points. Drilling the holes on the wall according
the marks.
WARNING:
The inverter must be mounted vertically on a vertical wall.
Use suitable expansion screws of bolts to attach the bracket
To the wall of rack as shown in figure 5.4.
The inverter should be mounted in a vertical position. The steps of mounting are as follows:
3. Using the expansion bolts to fix the bracket to the wall.
Install on a vertical surface or structure capable of bearing the weight.
Must install vertically within +/- 5. If the inverter is tilted from the vertical plane heat
dissipation can be inhibited. This may reduce system performance or reduce service
life of the inverter.
Visibility of the LED status indicator lights and LCD display screen should be considered.
NOTE:
The inverter must be installed out of reach of children.
A minimum of 500mm clearance is required top bottom left and right of the inverter
(isolator enclosures excepted) for air flow and cooling.
500mm500mm 500mm
500mm
Figure 5.2 Inverter mounting clearance
# $
%
5. Installation
A sun shade is recommended to minimise direct sun exposure where ambient
temperature may exceed 40 .℃
5. Installation
.12. .13.
Figure 5.3 The dimensions of the mounting bracket (in mm)
500mm
500mm 500mm

5. Use supplied screws to secure the bottom of the inverter to the mount bracket.
5.3 Electrical Connections
The electrical connection of the inverter must follow the steps listed below:
1. Switch the Grid Supply Main Switch (AC) OFF. Switch the DC Switch OFF.
2. Connect the inverter to PV array.
3. Connect the inverter to the grid.
The Inverter is designed with quick-connect terminal port for electrical connection
without removing the cover. The meanings of the symbols at the bottom of the inverter
are listed in Table 5.1. All electrical installations must be in accordance with all local
and national standards.
Table 5.1 Electrical connection symbols
GRID
COM1
Connecting terminal of the Grid
DC 1- DC4
+
_
Positive DC input terminal
Negative DC input terminal
DC SWITCH
Switch of DC input terminals (optional)
Communication port for Wi-Fi or GPRS stick
COM2 : COM3
Communication port of RJ45
Figure 5.6 Secure the inverter
4. Lift up the inverter and make the slot on the back bracket of inverter align to the
lip on the mounting bracket. Then lower the inverter to the bracket slowly until it
is stable (in figure 5.5).
Figure 5.4 Mount the bracket to the wall
Figure 5.5 Attach the inverter to the bracket
5. Installation 5. Installation
.14. .15.
Questo manuale è adatto per i seguenti modelli
7
Indice
Altri manuali MasterPower Invertitore

MasterPower
MasterPower MasterPower 3.6KW Manuale utente

MasterPower
MasterPower OMEGA 2.2KW LS Manuale utente

MasterPower
MasterPower RAI-3K-48ES-5G Manuale utente

MasterPower
MasterPower OMEGA 2.2KW Manuale utente

MasterPower
MasterPower MF-OME-X-6KV2 Manuale utente

MasterPower
MasterPower Delta UM Series Manuale utente

MasterPower
MasterPower BETA RHI 6K-48V 1P Series Manuale utente

MasterPower
MasterPower OMEGA LV Series Manuale utente

MasterPower
MasterPower Omega ESS 5.5KW Manuale utente