Matrix COSEC ATOM RD300 Manuale utente

COSEC ATOM
Safety Instructions
Cautions
Warning
Quick Installation Guide
These instructions are intended to ensure that the user can
use the product correctly to avoid danger or property loss.
Do not install the device:
ŸOn unstable surface.
ŸWhere ferromagnetic field or noise is induced.
ŸWhere static is created, such as desks made of plastics, carpets.
ŸNear volatile inflammable materials or inflammable goods such as
drapes.
ŸWhere volatile gas and/or inflammable gas is created.
ŸInstalling and servicing should be done only by qualified
technician.
ŸThere are no user-serviceable parts inside.
ŸOpening or removing the device cover may result in electric
shock or exposure to other hazards.
ŸUse the device only for the purpose for which it was designed.
ATOM RD100
ATOM RD200ATOM RD300
123
456
789
*0#
11.19"

Contents
Please read this guide first for correct installation and retain it for future reference. The information
in this guide is prevailing at the time of publication. However, Matrix Comsec reserves the right to
make changes in product design and specifications without prior notice.
Copyright
All rights reserved. No part of this document may be copied or reproduced in any form or by any
means without the prior written consent of Matrix Comsec.
Warranty
Limited Warranty. Valid only if primary protection is provided, mains supply is within limit and
protected, and environment conditions maintained within product specifications. Complete
warranty statement is available on our website:
www.matrixaccesscontrol.com
Know your ATOM
4
4
Know your ATOM
What your Package Contains
Things you will Need
Technical Specifications
LED and Buzzer Indications
Connecting the Reader
Installation
6
6
29
31
35
7
ŸCOSEC ATOM is a slave reader which can work with COSEC ARGO,
COSEC VEGA, COSEC PATH V2 using RS-232 and with COSEC ARC
rd
DC200 using RS-485. It can also work with 3 party Wiegand
Interface.
ŸIt is an intelligent compact Access Control Device which supports
Bluetooth and Card Credentials for Access Control and Time &
Attendance.
ŸCOSEC ATOM has three main variants that contains either Matrix FP
sensor(MF) or Suprema Sensor(SF). The respective variants are
listed below,
3
Type 1: COSEC ATOM RD300
1
2
3
3
3
4
5
Figure 1: Front View Figure 2: Back View
1. Display Screen
2. Finger Sensor
3. Mounting Screw Hole
4. Cable Assembly
5. Mounting Plate
ŸATOM RD300MFM
ŸATOM RD300MFI
ŸATOM RD300SFM
ŸATOM RD300SFI
Sub Variants
*ATOM RD300SFE
*ATOM RD300MFE

Type 2: COSEC ATOM RD200
1
2
3
3
3
4
5
Figure 3: Front View Figure 4: Back View
1. LED Indicator
2. Finger Sensor
3. Mounting Screw Hole
4. Cable Assembly
5. Mounting Plate
Sub Variants
Type 2: COSEC ATOM RD200
Type 3: COSEC ATOM RD100
1
2
Figure 5: Front View
Figure 6: Back View
3
3
5
4
1. LED Indicator
2. Numeric Keypad
3. Mounting Screw Hole
4. Cable Assembly
5. Mounting Plate
What your Package Contains
ŸCOSEC ATOM Unit
ŸCable Assembly
ŸWall Mounting Accessories
ŸFlush Mounting Accessories (with Type 1 and Type 2 only)
ŸATOM RD200MFM
ŸATOM RD200MFI
ŸATOM RD200SFM
ŸATOM RD200SFI
ŸATOM RD100KM
ŸATOM RD100KI
ŸATOM RD100M
ŸATOM RD100I
Things you will Need
ŸPower Drill
ŸScrew Driver Set
ŸA Wire Striper
ŸInsulation Tape
ŸNecessary Cabling
ŸWiegand supported device
ŸAccess to COSEC Server Application to configure COSEC
ATOM
Before you Start
Make sure,
ŸThe device in the package is in good condition and all the
assembly parts are included.
ŸAll the related equipments are powered-off before installation.
6
5
Sub Variants
*ATOM RD100KE
*ATOM RD100E

8
7
Installation
Mounting Plate
ŸFrom the bottom of the COSEC ATOM RD200/300, unscrew
the Mounting screw with the help of screw driver as illustrated
in Figure 8.
ŸSeparate the Mounting plate from the ATOM by pulling it
downwards. Refer, Figure 9 for the same.
Step 1: Removing the Mounting Plate
Figure 8
Figure 9
1) Installing the COSEC ATOM RD200/300: Wall Mounting
Step 2: Connecting the Cables
ŸYou can mount COSEC ATOM RD200/300 in two ways :
Concealed Wiring or Non-concealed Wiring as explained
below.
A. Concealed Wiring
1. Take the Mounting Plate and trace screw holes A , B & C. Trace
out the area D also drill along the marking as shown below.
A
Figure 10
B
C
D
A
B
C
D

10
2. Affix the mounting plate with the help of the screws and screw
grips through the holes A, B and C.
Figure 11
9
3. Lead the cables from the wall through the drilled area D of the
Mounting Plate as illustrated in Figure 12. Connect the necessary
cables with COSEC ATOM.
Figure 12
A
B
C
D

11 12
B. Non-Concealed Wiring
1. Follow the Step 1 and Step 2 as explained for the Concealed
Wiring and fix the mounting plate on the wall.
(For non-concealed wiring, you do not need to drill the area D.)
Figure 13
3.Pull out the Cables from the Back Plate hole and lead the cables
outside from the bottom opening of COSEC ATOM, as illustrated
in Figure 14.
4. Connect the necessary cables and align the COSEC ATOM
body with the Mounting Plate.
Back Plate
Figure 14
2. Unscrew the Back Plate screw with the help of screwdriver
and remove the Back Plate.

13
14
1. Fix the Reader body with the Mounting Plate such that the
Mounting Slots of the Reader and Mounting Plate align with each
other.
Figure 15
Step 3: Inserting Mounting Screw
2. Slide the reader downwards to fix it into the groove of the
Mounting Plate and insert the Mounting screw back in place at the
bottom of the device.
3. Tighten the screw with 2 kgf-cm torque as shown in Figure 17.
Figure 17

2) Installing the COSEC ATOM RD200/300: Flush Mounting
Step 1: Take the Surface Mount Plate provided with the package
and trace screw holes A, B, C and D on the surface where COSEC
ATOM is to be installed, see Figure 18. After tracing drill along the
markings as shown in Figure 19.
A
B
C
D
A
B
C
D
Figure 19
Step 2: Assemble the device with the Surface Mount Plate as
shown in Figure 20.
Figure 18
16
15

Device Surface
Mount Plate
Figure 20
Step 3: To connect the cables refer below image for Concealed
and Non-concealed Wiring positions.
Cut-out for Concealed Wiring
Cut-out for Non-concealed
Wiring
18
17

Step 5: Place the Surface Mount Top Facia Plate on the installed
Device, see Figure 22.
Figure 22
Front View
Figure 21
A
B
C
D
Step 4: Affix the Surface Mount Plate with the Device on the
surface with the help of the screws and screw grips through the
holes A, B, C and D, see Figure 21.
20
19
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Matrix Controllori di accesso IP