SAFETY
1. BE SURE TO GROUND!!
Be sure to ground the power supply unit before use.
2. DO NOT TOUCH ANY HIGH VOLTAGE TERMINALS!!
Do not operate the power supply unless someone who is familiar with the operation precede, the
hazards of high voltage, and the treatment for the electrical shock is present.
3. UNDERSTAND THE HAZARDS OF HIGH VOLTAGE!!
In case you let somebody operate the power supply for you, must be sure that he/she fully
understands the hazards of high voltage and the areas where never can be touched.
4. CUT OFF THE POWER BEFORE TOUCH THE UNIT!!
Cut off the power, and check that the power is OFF, before you touch the power supply.
Capacitors in the output circuit are still charged and dangerous even after the power has been
cut off.Discharge all remaining high voltage by grounding them.
5. DISCONNECT THE INPUT LINES(AC LINES) !!
In case you need to touch the inside of the power supply following instruction manual, cut off
the power and disconnect the input lines(AC lines), and ground all the capacitors and high
voltage section.
Don’t remove the case or touch the inside of power supply unless so instructed in the
instruction manual.
6. OPERATE THE POWER SUPPLY WITH YOUR RIGHT HAND!!
In order to avoid the electric shock to your important organs, operate the power supply with
your right hand and keep your left hand off from the power supply.
This power supply unit generates high voltage and energy.
Electric shock may lead to death or serious injury.
Be sure to follow the instructions below and handle the unit with caution.

ii
Various symbols are used in this instruction manual and on the product for ensuring safety.
What will be caused by ignoring the instructions given with the symbols or by improper handling
are classified as shown below. Read carefully and understand the descriptions before
proceeding to the main body of this manual.
Symbols
Meanings of the Symbols
Some of the symbols used
are shown on the right.
Indicates that which requires caution.
Indicates that which forbidden.
Indicates that which must be done.
Indicates electric shock hazard.
failure to follow the instructions with this indication may lead to death or serious injury.
failure to follow the instructions with this indication may lead to injury or damage in property.
Warning:
Caution:
!
!
!
!
!
Warning
Do not touch the output terminal or the
leads or load connected to it while the
unit is in operation or immediately after it
is stopped. Otherwise it may cause
electric shock or injury.
Do not install the unit in a place subject
to steam or water vapor.
Otherwise it may cause poor insulation
and lead to fire or electric shock.
Do not install the unit in a place subject
to dew condensation.
Otherwise it may cause electric shock.
Do not modify or damage the cables.
Otherwise it may cause electric shock.
Be sure to ground the unit to avoid a rare
possibility of electric shock.
Otherwise it may lead to fire, electric
shock or injury.
Do not place any object on the unit.
Dangerous situations may occur if the
object drops or falls.
Do not put any object in the unit.
It may cause damage.
Do not disassemble, remodel or repair the
unit. High voltage may be built up inside,
which may cause electric shock.
Disassembly, remodeling or repair hamper
ensuring of safety and may lead to
dangerous situations.
Do not install the unit outdoors or in a
place subject to leaking of water, flood
or snow.
Otherwise it may cause electric shock.
NO
NO
NO
NO
DISASSEMBLY
NO
NO
GROUND
NO

iii
■ After reading this manual, be sure to store it in a place convenient for the users so that it can be
referred to at anytime.
!
Caution
Do not install the unit upside down or
on a wrong side.
Insufficient heat release may cause
deterioration of parts, which may
generate smoke or set fire.
Do not use the unit in a place subject to
high temperature or in an enclosed,
limited area.
It not only hampers the unit from
achieving its performance but also
causes deterioration of parts leading to
smoking or burning.
Do not wipe the unit with chemicals
(such as thinner) or wet cloth.
It may allow water inside leading to
electric shock, electrical leak or burning.
Do not cover the vent holes of the unit.
Vent holes are provided to prevent
elevation of temperature inside.
Covering them not only hampers the unit
from achieving its performance but also
causes deterioration of parts, which may
generate smoke or set fire.
Do not install the unit and the remote
controller in a place subject to direct
cold air. Condensation may lead to
electrical leak/burning.
Do not install the unit in a place subject
to corrosive gas or liquid (such as a
place where chemicals are handled).
Deterioration of parts may cause
generation of smoke or burning.
NO NO
NO NO
NO NO

iv
RESCUE
1. Free victim from contact with live conductor quickly.
Avoid contact with neither live conductor nor victim’s body.
2. Shut off high voltage at once and ground the circuit. If high voltage cannot be turned off
quickly, ground the circuit to discharge, or cut high voltage line by an ax with dry wooden
handle. Be careful of electric flash.
3. If circuit cannot be broken or grounded, use a dry board, dry clothing, or other
nonconductor to free victim.
4. Call an ambulance immediately.
SYMPTOMS
NEVER TAKE ELECTRICALLY SHOCKED CONDITION AS DEATH.
Symptoms of electric shock may include unconsciousness, failure to breathe, absence of
pulse, pallor, and stiffness, as well as severe burns.
Whenever victim is not breathing properly, give artificial respiration(see next page).
TREATMENT
1. Start artificial respiration at scene of accident. Only in case victim’s or
operator’s life is endangered, remove victim to safe location nearby.
2. After starting artificial respiration, continue without loss of rhythm until victim start
breathing without help, or being passed to medical aid.
3. When operator change while giving artificial respiration, do so without losing the
rhythm of respiration.
4. After giving first aid, try to get a diagnosis by a doctor as soon as possible because
shock can cause internal burn, which can be lethal if left untreated.
AFTER VICTIM REVIVES
Be prepared to resume artificial respiration, as he may stop breathing again.
Keep victim warm and lying down until he or she has been conscious for at least thirty minutes.
First-aid procedures to be implemented in case of electrical shock

v
1. PLACE VICTIM
Place victim in face-upward position horizontally.
2. CLEAR THROAT
Turn head to one side quickly wipe out any fluid, mucus, or
foreign body from mouth and throat with fingers.
3. OPEN AIR PASSAGE
Tilt head back and extend neck to open air passage.
4. LIFT JAW FORWARD
Put thumb in victim’s mouth and grasp jaw firmly. Lift jaw
forward to pull tongue out of air passage. Do not hold or depress
tongue.
5. PINCH NOSTRILS CLOSED
With other hand pinch nostrils closed to prevent air leak.
6. BLOW AIR IN
Take a deep breath, seal victim’s open mouth and exhale firmly into
victim’s mouth until chest is seen to lift.
Make sure to open mouth widely to avoid air leakage.
7. REMOVE MOUTH AND CHECK
Check the sound of breathing out air and see normal breathing
when releasing mouth. If no sound, repeat from OPEN AIR
PASSAGE. Continue at a rate of 12 to 20 times per minute.
Quantity of air have to be increased gradually. Especially when victim is infant, be carefully not to be
too strong, not to blow in too much air.
Keep giving artificial respiration until victim start breathing without help, or being passed to medical
aid.
Artificial respiration
7.Remove mouth and
check
6.Blow air in
3.Open air
passage
2.Clear throat

vi
1. WARRANTY POLICY
Matsusada Precision Inc. ("Matsusada") warrants that the products supplied by it will be free from
defects in materials and workmanship for a period of twelve (12) months from the date of original
shipment to buyer. This warranty shall not apply to any product which has been repaired, modified
or worked on by persons unauthorized by Matsusada, used other than in accordance with the
instruction manuals, used in inappropriate environment (with corrosive gas, high humidity, etc) or
damaged by any event beyond Matsusada's control such as force majeure. Matsusada shall in no
way be liable for any incidental, special or consequential damages relating to this warranty.
Matsusada's sole liabilities and the buyer's sole remedies shall be limited, at Matsusada's discretion,
to a repair or replacement of the products.
The foregoing warranty is in lieu of all other warranties, express or implied, including those of
merchantability or fitness for a particular purpose.
As the products are not designed and manufactured for applications which require extraordinary
reliability or safety, or affecting people's life (nuclear energy, aerospace, socially fundamental
facility, medical equipment, etc), this warranty shall not be applied for such applications. The
specific design and manufacturing might be required for such applications.
No modification or supplement of this warranty shall be binding unless in writing and signed by a
duly authorized officer of Matsusada.
2. INSTRUCTION MANUAL AND TEST DATA
・Each rack mount and bench top power supply have 1 instruction manual. Extra instruction manuals
available with charge.
・Schematics of products shall not be submitted to users. Test result or test data for the products
shall be available upon request with charge.
WARRANTY

1. Introduction
1-1 Introduction
1-2 Unpacking the bi-polar amplifier
1-3 Environmental requirements
1-4 Points to be careful about in handling and care
1-5 What to do before calling service
1-6 Characteristics of bi-polar amplifier
1-7 Connection Precaution
2. Exterior view diagram
2-1 Front panel (~350W(Io≦30A) type)
2-2 Rear panel (~350W(Io≦30A) type)
2-3 Rear panel (300W (60A≦Io<80A) ・600~720W(Vo<120V)type)
2-4 Front panel (600~720W(Vo<120V and Io<60A)type)
2-5 Rear panel (600~720W(Vo<120V and 60A≦Io<80A) type)
2-6 Rear panel (600~720W(120V≦Vo or 80A≦Io)・1.2kW・2kW type)
2-7 Rear panel (600~720W(120V≦Vo)type)
2-8 Rear panel (1.2kW・2kW(Io<80A)type)
2-9 Rear panel (80A≦Io type)
3. Instruction for handling
3-1 Overview
3-2 Connection to the load
3-3 Connection of AC input cable
3-4 Operations
3-5 Select CV/CC setting
3-6 Using bias
3-7 Remote sensing
3-8 Other features
a.Over Voltage Protection (O.V.P)
b.Over Current Protection (O.C.P)
c.Power outage protection
3-9 Over Current Protection
3-10 Output Range
3-11 Remote ON/OFF switch
3-12 Inter lock
4. Optional Features
4-1 Cancel power outage protection (LN)
4-2 RMS display of output voltage and output current (LPr)
4-3 Master slave option (LMs)
4-4 Floating ground (LF)
4-5 Output voltage limit (LVc)
4-6 Output current limit (LCc)
5. LMs option Instruction Manual
5-1 LMs option
5-2 How to use
5-3 Connection of master unit and slave unit
5-4 Application consideration
Table of contents
Page
1
1
1
1
2
2
3,4
4
5
5
5
6
6
7
7
8
9
10
11
11
11
11
12
12
12
13
14
14
14
14
14
15
16
17
18
18
18
18
18
18
19
20
20
20
21
21

1
1-1 Introduction
Thank you very much for your purchase of our product.
DOP series is a rack-mount four-quadrant fast response bi-polar power supply.
We have done our best for the quality control of our products. Please handle this unit
properly according to this instruction manual so that you can use the full performance of
this unit safely for long.
We have carefully prepared this instruction manual, but if you find any doubtful or
unclear point or any omission, please kindly contact us shortly.
1-2 Unpacking the bi-polar amplifier
When unpacked the unit, you will please check the following accessories are enclosed with
the power supply main body.
〈Accessories〉
・ AC input cable (1 pc.)
・ Instruction manual
・ Master-slave connection cable (with –LMs option)
1-3 Environmental requirements
・ Place and use the power supply horizontally.
・ Never place any object on the power supply.
・ There are air suction and exhaust holes for cooling at upper part and sides of the
power supply. Provide an ample space to the power supply, and use it at the place
where the ventilating condition is good.
・ Avoid using the unit at such places where it is very dusty or there is corrosive gas.
1 Introduction
1 Introduction

2
1-4 Points to be careful about in handling and care
WHEN TOUCHING LOAD AFTER TURNING OFF THE OUTPUT
1. Make the setting of an output voltage to zero (0). Turn off the OUTPUT ON/OFF
switch.
2. Check and confirm that the voltage is zero at an output voltmeter of this unit.
3. Turn off the POWER ON/OFF switch.
4. Earthling an output for more than 10 seconds, check and confirm that the voltage is
zero with another high voltage meter. It is especially dangerous that the load is
capacitive or a long cable is used.
5. Make it a rule to touch load with right hand.
FOR SAFER OPEREATION
1. Laying an insulation plate which can withstand the voltage to be used on the floor on
which an operator stands, carry out the operation. If done so, it will be comparatively
safe.
2. When operating a power supply and load, do so with right hand with left hand put in the
pocket, taking care not to touch other objects.
3. After turning off the voltage (even if a long time has lapsed after turning off), if you
touch load, be sure to earth the output longer than 10 seconds.
1-5 What to do before calling service
In case no output
1. Check whether or not a specified voltage has been inputted.
100-120VAC 50/60Hz single phase of input voltage.
(For output power of 600W or higher, 200-240VAC 50/60Hz single phase)
2. Check whether or not a connection is correct.