Maximum 21030 Manuale utente

English User manual
Deutsch Installationsanleitung
Dansk Brugervejledning
Powerline Network System
Internet access to any power outlet
MAXIMUM 500 LOOP KIT
Item no.: 21030

2
Installation Guide
This document describes installation of the powerline products.
Please read this document before installing the product.
This publication contains the following sections:
• Important safety instructions
• The first thing you need to know before you begin to install
• Product installation guide
• Specification
Important Safety Instructions
This product is intended for connection to the AC power line. For instal-
lation/removing instructions, refer to the Installation section. The following
precautions should be taken when using this product.
• Please read all instructions before installing and operating this product.
• Please keep all instructions for later reference.
• Please follow all warnings and instructions marked on the product.
Cleaning / reservations
• Unplug the AC coupler from the wall outlet before cleaning. Use a damp
cloth for cleaning. DO NOT use liquid cleaners or aerosol cleaners.
• Do not operate this product near water.
• Use only in dry conditions, not for outdoor use.
• The total wattage of the connected devices must not exceed 2300 watts.
• This product should never be placed near or over a radiator, or heat register.
• This product relies on the building’s electrical installation for short-circuit
(over current) protection.
• Ensure that a fuse or circuit breaker no larger than 120 VAC 20A or 240 VAC
16A is used on the phase conductors (all current-carrying conductors).
• Do not allow anything to rest on the product interconnect cords.
• Do not locate this product where people may walk on the cords.
• The product can be operated at an ambient temperature of 40°C.
English

3
• For pluggable equipment, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
• Only a qualified technician should service this product. Opening or removing
covers may result in exposure to dangerous voltage points or other risks.
• Unplug the AC coupler from the wall outlet and refer the product to quali-
fied service personnel for the following conditions:
• When the interconnect cords are damaged or frayed.
• If liquid has been spilled into the product.
• If the product has been exposed to rain or water.
• If the product does not operate normally when the operating
instructions are followed.
• If the product exhibits a distinct change in performance.
The first thing you need to know before you begin to install the CD
1. Before installing, make sure your PC meets these requirements
for hardware installation:
• Microsoft Windows® 98SE, ME, 2000, XP, Vista, Mac OS or linux OS
• Pentium® III or better, clock rate faster than 2.0GHz recommended
• At least one free Ethernet port for 500Mbps PLC Pass Through
2.YourPCmustnotbeconguredforanothernetwork.Thismeansthat:
• No network clients except for Microsoft Network*, Client for Netware*
Networks, or Microsoft Family Logon* are installed.
• NonetworkservicesexceptleandprintersharingforMicrosoftNetworks
or Personal Web Server* are installed
• No network protocols except Microsoft’s TCP/IP, IPX/SPX, NetBEUI, or
Net BIOS support for IPX/SPX are installed
3. Network installation requires two steps:
• Install the 500Mbps PLC-Pass Through
• For each PC to be added to the network, repeat the process
4. Check that you have the following parts for each PC on the network:
• Product installation guide for 200Mbps PLC Pass Through
English

4
• 500Mbps PLC Pass Through
• Ethernet Cable (CAT 5)
5. Familiarize yourself with the Powerline device connections:
• There is only one Ethernet port. This is used for the connection with PC,
xDSL/Router, Cable Modem, or Wireless AP.
6. Limitation of the PLC device:
• To meet the safety regulation, the longest distance between powerline
carrier devices will be limited at 200 meter and for in-house use only.
More than 200 meter will cause the signal reduction or data loss.
• Always connect to the nearest source where possible and avoid exten-
sions power connectors. Every step that brings you further away from the
source (your power network) will cause signal reduction or loss.
• There are some limitations in regards to the house main installation.
Some phase jumps might not be possible or cause signal reduction or loss.
Product Installation Guide
Notice:
Do not plug the device into a power strip or surge protector because these
devicesmayconsistoflterandimpairsignal.Alsoavoidpluggingthe
device right next to noisy sources such as cell phone charger, Halogen light,
Energy saving bulb, noisy desktop computer, vacuum cleaner, etc. Both
cases result in poor transmission speed. Nevertheless, you can put the
noisysourcetothePassThrough’soutlet.Theoutletwilllteroutthenoise
and improve the Powerline communication performance.
English

5
To install for the PC local Powerline network
• Use the supplied Category 5 Ethernet cable to connect powerline product
and your PC’s Ethernet port.
• Plug the powerline product to power outlet.
• The PWR LED indicator will light on after plugging.
• You can repeat steps 1 and 2 for connecting the others.
• The PLC-ACT LED indicator starts blinking when the data communication
proceeds on Powerline.
• The ETH-ACT LED indicator starts blinking when the data communication
proceeds on Ethernet.
To share a xDSL or cable modem with Internet access service
1. Connect one powerline product to the broadband router
• Plug the powerline into an AC outlet.
• Plug the provided Ethernet cable into the RJ45 connector of the
powerline product and plug the other end of the cable into an available
Ethernet port of the Router.
2. Connect the other powerline products(s) to the PC(s) to share the Internet access
• Plug the Bridge into an AC outlet.
• Plug the provided Ethernet cable into the RJ45 connector of the powerline
product and plug the other end of the cable into Ethernet port on the PC.
As wireless AP (Access Point) Extender
1. Connect one powerline to the broadband router
• Plug the Bridge into an AC outlet.
• Plug the provided Ethernet cable into the RJ45 connector of the
powerline product and plug the other end of the cable into an available
Ethernet port of the broadband router.
2. Connect the other Pass Through to the wireless AP.
• Plug the Bridge into an AC outlet.
• Plug the provided Ethernet cable into the RJ45 connector of the powerline prod-
uct and plug the other end of the cable into the Ethernet port on the wireless AP.
English

6
Installation
Because powerline product sends data over the powerline, it is recommended that
you plug directly into a power outlet. Do not plug the device into a UPS or power
stripwithsurgeprotection.Thepower-passthroughproducthasitsownpowerlter
for protection against surges.
English

7English
LED/buttons
*1 : The “Power“ LED indicator will blink in standby mode. It will get into standby
mode, if you plug the device to outlet and no Ethernet link detected after booted
and 60 second later. If you unplug the Ethernet cable, it will get into standby mode
after 60 seconds. Under standby mode, PLC and ETH LEDs will both be off.
Push Buttons (Only applicable for models with push button)
Push button functions are disabled under Standby mode.
Setup Button Usage:
First time to setup your private network:
Step 1.
Press and hold the device’s “SETUP” button for more than 10 seconds. You can re-
lease the button when you see all the device’s LEDs are off and restart. The original
network encryption setting is cleared.
Step 2.
Repeat Step 1 to clear another device’s original network encryption setting.
Step 3.
Press both devices’ “SETUP” button for 1 to 3 seconds. You will see both devices’
“Power” LED start blinking. Both devices start to communicate and try to setup their
private network encryption. They will complete the new private network encryption
setting within 10 seconds. You will see both devices’ all LEDs are off and restart.
Note: The setup operation timeout is 120 seconds.
PWR
(Red)
On: Power on
Blinking: Standby mode (*1)
PLC
(Green/Orange/Red)
ETH
(Green)
On: Ethernet Link detected

8
Step 4.
If failed, please repeat Step 1 to Step 3 again.
Add a new device to the existing private network:
Step 1.
Plug the new device. Press and hold its “SETUP” button for more than 10 seconds
to clear the original network encryption setting.
Step 2.
Press the new device’s “SETUP” button for 1 to 3 seconds. The “Power” LED starts
blinking.
Step 3.
Select a random device from the existing private network. Press its “SETUP” button
for 1 to 3 seconds. The device’s “Power” LED starts blinking.
Step 4.
The new device starts to communicate with the device from existing private net-
work, and tries to join this existing private network. It will complete the new private
network encryption setting within 10 seconds. You will see the new device’s all
LEDs are off and restart after completing the private network setting. The existing
private network device’s “Power” LED become solid.
Note: The setup operation timeout is 120 seconds.
Step 5.
If failed, please repeat Step 1 to Step 3 again.
Leave the private network:
Step 1.
If the device wants to leave the private network, press and hold the device’s
“SETUP” button for more than 10 seconds to clear the network encryption setting.
This device will leave the private network.
Reset Button Usage:
1. Reset the device to the factory default setting:
Push the device’s “RESET” button for 1 to 3 seconds. You will see the device’s all
LEDs are off and restart. The device’s setting resets to the “factory defaults”.
English

9
Specikation
English
Powerline Network
©2010 . All rights reserved. Page 6
Specification
Items Description
PHY Rate 500Mbps(IEEE 1901 and HomePlug® AV compliant)
Effect Data Rate TCP: Up to 210 Mbps effective throughput ,250 Mbps with multiple sessions
UDP: Up to 250Mbps effective throughput
Frequency Band 2~68 MHz (With Mask)
Access Methods priority-based CSMA/CA channel access schemes maximize efficiency and
throughput
Qos –Integrated Quality of Service (QoS) Enhancements
–Hardware Packet Classifiers for ToS, CoS and IP Port Number
–Supports IGMP managed multicast sessions
Modulation OFDM (QAM 8/16/64/256/1024/4096, QPSK, BPSK, ROBO)
Standards IEEE 802.3, IEEE 802.3U,HomePlug AV Protocol Compliance with HomePlug
1.0 coexistence capability
Operating System Microsoft Windows®2000, XP, Vista ,Windows 7(for utility-program only)
Nodes
Up to 63 slaves with 1 master, 64 total devices
4 overlapping networks for neighbor networks with CCo failover
Up to 4 masters with up to 252 slaves, 256 total devices in 4 AVLNs
Max 64 bridged devices per station
Up to 4096 addressable devices including bridged devices
IGMP IGMP snooping with multicast to multiple unicast support in CSMA
o Enhanced IPv4/IGMPv1-3 snooping support
o Enhanced Support for IPv6 and MLDv1-2 snooping
Encryption 128-bit AES Link Encryption with key management
Push button SETUP button
RESET button
Port One 100M/Giga Bit Ethernet port
Distance AC Wire : 200 meters
LEDs PWR (Red)
PLC(Green/Orange/Red throughput indicator)
ETH (Green)
Environment Temperature Operating : 0~40 ℃
Storage : -20~60 ℃
Relative Humidity Operating : 10~85% Non-Condensing
Storage : 5~90% Non-Condensing
Power Source 100 ~240 VAC 50/60Hz
Power
Consumption 5W Max (Normal mode)
Below 2W (Standby mode)
Certification CE

10
English
Utility Program User Guide for powerline products
Index
1. Introduction 10
1.1. System Requirements 10
1.2. Installation 10
1.3. Run the Utility 11
2. How to use 11
2.1. Main Tab 11
2.2. Diagnostics Tab 15
2.3. About Tab 16
1. Introduction
ThisUtilityProgramenablesuserstond500MbpsPLC-EthernetBridge
devices on the Powerline network, measures data rate performance, ensures
privacyandperformsdiagnosticsbysettinguserdenedsecurePowerline
networks.
1.1. System Requirements
Operating System Microsoft Windows XP, Vista, 7
Browser Microsoft Internet Explorer 5.0 or later.
CPU Intel Pentium III or better, clock rate faster than 2.0GHz recommended
RAM At least 128MB
Free Disk Space At least 20MB
Network Interface At least one Fast/Gigabit Ethernet network card, and Ethernet Cord
1.2. Installation
First, you need to verify that there is no other Powerline utility installed on
your computer before installing this utility. If there is another utility installed,
please uninstall it.
Then, please insert the Utility CD-ROM into the computer’s CD-ROM drive.
The CD will launch an IE browser. Click the necessary link to start installa-
tion. Please install WinPcap v4.1.1 (you can download it from http://www.
Indice
Altri manuali Maximum Adattatore