MC Electronics MCK 800 Manuale utente

MCK 800
COMPUTER FOR
PRECISION SEED DRILLS
NR. 2611-EN
REV. 1 EN
USER’S MANUAL

User’s manual
SEEDER MONITOR MCK 800
2
This product complies with EMC requirements as defined by
Directives 2004/108/CE and successive modifications
in accordance with standard EN ISO 14982 applied
Manufacturer : MC elettronica S.r.l.
Address : Via E. Fermi, 450/486
Fiesso Umbertiano (ROVIGO) – ITALY
Tel. +39 0425 754713 Fax +39 0425 741130
E-mail: mcstaff@mcelettronica.it
Internet: www.mcelettronica.it
Manual code : 2611-EN
Issued : February 2001
Edition : November 2013
MC elettronica S.r.l. is not obliged to give notice of any further modifications of the product.
The information given in this manual does not allow unauthorized personnel to tamper the product
in any way. The guarantee on the equipment will no longer be valid if tampering should be
detected.
© Copyright MC elettronica 2013

User’s manual
SEEDER MONITOR MCK 800
3
Content
1. Rules and general warning .................................................................................. 4
1.1 Introduction ....................................................................................................... 4
1.2 Terms of guarantee ........................................................................................... 5
1.3 Service .............................................................................................................. 5
2. General description .............................................................................................. 6
2.1 How to install the system ................................................................................... 7
2.1.1 Wiring attachments .................................................................................... 7
2.2 How to install the sensors ................................................................................. 8
2.2.1 How to install the speed sensor D.18 cod. 481 .......................................... 8
2.2.2 How to install the photocells ....................................................................... 9
3. Front view ............................................................................................................ 12
4. Accessories ......................................................................................................... 13
5. Using the Seeder Control MCK 800 ................................................................... 14
6. Programming ....................................................................................................... 15
6.1 Programming the working width ...................................................................... 15
6.2 Programming the “C” parameter (pulses / 100 metres) ................................... 16
6.2.1 Practical example for calculating the C parameter to be programmed ..... 17
6.3 Automatic calibration of “C” parameter ........................................................... 18
6.4 How to set the rows-alarm sensitivity .............................................................. 18
6.5 How to check speed sensor for functioning ..................................................... 19
6.6 How to check photocells for functioning .......................................................... 19
7. Maintenance ........................................................................................................ 20
7.1 Ordinary maintenance ..................................................................................... 20
7.1.1 How to protect the main connector ........................................................... 20
7.2 Extraordinary maintenance ............................................................................. 20
8. Technical data ..................................................................................................... 21
8.1 Seeder Monitor MCK 800 ................................................................................ 21
8.2 Technical data accessories ............................................................................. 21
8.2.1 Speed sensor D.18 cod. 481 .................................................................... 21
8.2.2 Photocell sensor cod. 4228 ...................................................................... 22
8.2.3 Photocell sensor cod. 10FOT-SEMIMINUTI-0001 / 10FOT-4RXTES /
10FOT-4RXTIN ................................................................................................. 22
8.2.4 Cables cod. CAB-SEM-001, CAB-SEM-002, CAB-SEM-003 ................... 22

User’s manual
SEEDER MONITOR MCK 800
4
1. Rules and general warning
1.1 Introduction
This manual gives all the specific information that you need for a proper use of the
equipment.
After buying the instrument, read the manual carefully and refer to it any time you
have doubts on how to use the equipment or when you have to carry out
maintenance operations.
Keep the manual on the machine. If this is not possible, keep it ready to hand.
ALL RIGHTS RESERVED. THIS MANUAL IS INTENDED FOR CUSTOMERS ONLY. ANY
OTHER USE IS FORBIDDEN.

User’s manual
SEEDER MONITOR MCK 800
5
1.2 Terms of guarantee
SUBJECT OF THE GUARANTEE: the guarantee is applied to the product and to
those parts which are marked with the serial number or any other identification
number used by MC elettronica;
HOW LONG THE GUARANTEE IS EFFECTIVE: MC elettronica S.r.l.
guarantees the MCK 800 Monitor for a period of 1 year from the manufacturing
date (printed on the identification label which is to be found on the rear side of
the equipment) and also accessories.
The guarantee covers the product and any repair carried out within the
agreed terms.
This guarantee does not apply in the event of:
accidental damage;
improper use;
modifications which haven’t been agreed upon, improper installation (or
setting);
damage caused when a non-MC elettronica equipment, which is
mechanically or electrically connected to our instruments, breaks or does not
function properly;
act of God (lightning, floods, fire or other causes which do not depend from
MC elettronica).
Repairs under guarantee, which must be carried out in the laboratories of our
authorized centres, are entirely free of charge provided the equipment is directly
transported to said laboratories or sent free port. Transport charges and risks are
entirely borne by the Customer.
The above-mentioned guarantee is valid unless otherwise stated between MC
elettronica and the Customer.
!
Warning
Mc elettronica declines any liability for damages or direct or indirect
charges, as a consequence of improper use or inability of the Customer
to use the equipment separately and/or together with other instruments.
1.3 Service
Service is available in all the countries where the equipment is officially supplied by
MC elettronica (during and after the guarantee period).
Any kind of operation that is to be carried out on the SEEDER MONITOR MCK 800
Computer must be done in accordance with the instructions stated in this manual or
as agreed with MC elettronica.
If not, the relative terms of guarantee might become void.

User’s manual
SEEDER MONITOR MCK 800
6
2. General description
The MCK 800 monitor is multifunction electronic instrument suitable for small
precision drills, pneumatic or mechanical control of sowing “monogerm” (corn,
soybean, sunflower, sugar beet, etc.)
The instrument controls the operation of the file indicating the LCD by horizontal bars,
any abnormality of sowing.
During the working cycle, the following data are displayed and controlled:
the width (width - PROG);
the 'working area: total and partial (Ha);
the status of files;
the hours worked on.
The computer carries out the above-mentioned operations by means of a series of
photocells installed on each single row of the seed drill for seeds counting, and a
speed sensor to be installed on a wheel of the machine.

User’s manual
SEEDER MONITOR MCK 800
7
2.1 How to install the system
2.1.1 Wiring attachments
MCK 800
Figure 1. Wiring attachments.
VEL
1 2 3 4 5 6 7 8
POWER CABLE
PHOTOCELLS
SPEED SENSOR
B
D
F

User’s manual
SEEDER MONITOR MCK 800
8
Connect the signal cable to the junction box (B) placed on the seed drill;
connect the speed sensor (VEL) and the photocells (D);
connect the supply cable (F) of the Computer to the battery of the vehicle;
connect the RED wire to the positive pole (+) and the BLACK wire to the
negative pole (-).
2.2 How to install the sensors
The MCK 800 Computer is equipped with 2 types of sensors:
speed sensor (always present) cod. 481;
photocell sensor (always present) cod. 4228, 10FOT-1269, 10FOT-
SEMIMINUTI-0001.
2.2.1 How to install the speed sensor D.18 cod. 481
You can install the speed sensor (cod. 481) anywhere there is a mechanic
movement, in the wheel (front or rear wheel) of the agricultural vehicle/machine, or by
making a metal reference which sticks out of at least 7 mm (Figure 1 – ref. <C>). We
recommend to install the speed sensor inside the wheel, by placing the head sensor
opposite the rim bolts (Figure 1 – ref. <A>).
Adjust the distance between the sensors and the bolts to about 2/3 mm (Figure 1 –
ref. <B>).
Fix the sensor holder bracket (supplied) to a fixed part of the vehicle/machine so that
it is well fixed to the structure. Lock the sensor to the bracket with the nut and lock
nut.
!
Warning
We recommend to protect the sensor cable with a rubber sheath.

User’s manual
SEEDER MONITOR MCK 800
9
Figure 1. How to install the speed sensor cod. 481.
2.2.2 How to install the photocells
Photocells must be placed on each single row of the seed drill close to the seed-drop
area; if seed drills with seed-drop pipes are used, photocells must be placed at about
half the length of the pipe.
To install photocells, proceed as follows:
distribute the photocells cables on the seed drill air pipes, respecting the row
numeration (Figure 2);
fix the junction box (A) at the centre of the seed drill with some clamps held to
the machine;
install the photocells taking into account the references of the sowing element
(reported on the technical sheet which is related to the type and mark of the seed
drill used, and enclosed with this manual).
!
Warning
make sure that photocells do not obstacle the seed-drop or the
mechanical functioning of the sowing element.
Speed sensor
Metal reference
Inner side of wheel

User’s manual
SEEDER MONITOR MCK 800
10
Figura 2. How to install photocells
Figure 3. Example of installation on the pipe (cod. 10FOT-4RSTES / 0FOT-4RSTIN)
Clamps
2-leds transmitter
3-leds receiver
Indice
Altri manuali MC Electronics Scrivania



















