McIntosh WK-3 Manuale utente

WK-3/WK-4
Owner’s Manual
McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699
Phone: 607-723-3512 FAX: 607-724-0549
Keypads

2
WARNING - TO REDUCE RISK
OF FIRE OR ELECTRICAL
SHOCK, DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR
MOISTURE.
The lightning flash with arrowhead,
within an equilateral triangle, is in-
tended to alert the user to the pres-
ence of uninsulated “dangerous volt-
age” within the product’s enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock to
persons.
NO USER-SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL.
To prevent the risk of electric shock, do not remove
cover or back. No user serviceable parts inside.
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and mainte-
nance (servicing) instructions in
the literature accompanying the
appliance.
IMPORTANT SAFETY
INSTRUCTIONS!
PLEASE READ THEM BEFORE
OPERATING THIS EQUIPMENT.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near
water.
6. Clean only with a dry cloth.
7. Do not block any ventilation
openings. Install in accordance
with the manufacturer’s
instructions.
8. Do not install near any heat
sources such as radiators, heat
registers, stoves, or other
apparatus (including amplifiers)
that produce heat.
9. Do not defeat the safety purpose
of the polarized or grounding-type
plug. A polarized plug has two
blades with one wider than the
other. A grounding type plug has
two blades and a third grounding
prong. The wide blade or the third
prong are provided for your safety.
If the provided plug does not fit
into your outlet, consult an
electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being
walked on or pinched particularly
at plugs, convenience receptacles,
and the point where they exit
from the apparatus.
11. Only use attachments/accessories
specified by the manufacturer.
12. Use only with the cart, stand,
tripod, bracket, or
table specified by the
manufacturer, or sold
with the apparatus.

3
When a cart is used, use caution
when moving the cart/apparatus
combination to avoid injury from
tip-over.
13. Unplug this apparatus during
lightning storms or when unused
for long periods of time.
14. Refer all servicing to qualified
service personnel. Servicing is
required when the apparatus has
been damaged in any way, such as
power-supply cord or plug is
damaged, liquid has been spilled
or objects have fallen into the
apparatus, the apparatus has been
exposed to rain or moisture, does
not operate normally, or has been
dropped.
15. Do not expose this equipment to
dripping or splashing and ensure
that no objects filled with liquids,
such as vases, are placed on the
equipment.
16. To completely disconnect this
equipment from the a.c. mains,
disconnect the power supply cord
plug from the a.c. receptacle.
17. The mains plug of the power
supply cord shall remain readily
operable.
Thank You
Thank you for your decision to own this
McIntosh WK-3 or WK-4 Keypad. The
McIntosh dedication to “Quality” is assur-
ance that it will provide you with many
years of enjoyment.
Please take time to read this manual, as
it will help you to become more familiar
with your new McIntosh Keypad.
Please Take A Moment
The serial number, purchase date and
dealer name are important for possible in-
surance claim or future service. The spaces
below have been provided to record that
information:
Technical Assistance
If you have questions about this product,
contact your McIntosh Dealer who is more
familiar with your component system. If
additional help is needed, you can receive
technical assistance at:
McIntosh Laboratory, Inc.
2 Chambers Street
Binghamton, New York 13903
Phone: 607-723-3512
Fax: 607-723-3636
Serial Number:
Purchase Date:
Dealer Name:
Copyright 2003 © by McIntosh Laboratory, Inc.

4
Table of Contents
Safety Instructions ................................. 2
Thank You .............................................. 3
Please Take a Moment ........................... 3
Customer Service ................................... 4
Table of Contents ................................... 4
Important Information ........................... 4
Connector Information .......................... 5
Introduction ........................................... 6
Performance Features ............................ 6
WK-3 Installation and Dimensions ....... 7
WK-4 Installation and Dimensions ....... 8
How to Connect with the
5-Pin Terminal Connector ..................... 9
How to Connect with the
RJ45 Connector ................................... 10
WK-3 Front Panel Push-Buttons ......... 11
WK-4 Front Panel Display
and Push-Buttons ................................. 12
How to Operate the WK-3 and WK-4 . 13
Specifications ...................................... 15
Packing Instruction .............................. 15
Customer Service
If your McIntosh product is in need of re-
pair, it can returned to your Dealer or the
McIntosh Service Department. For assis-
tance on repair return procedure, contact
the McIntosh Service Department at:
McIntosh Laboratory, Inc.
2 Chambers Street
Binghamton, New York 13903
Phone: 607-723-3515
Fax: 607-723-1917
Important Information
1. Before connecting the WK-3/WK-4 Keypads
to a McIntosh A/V Control Center,
Multizone Controller or Preamplifier make
sure that the Main POWER Switch on those
uints are in the Off position or unplug the
AC Power Cord from the wall outlet. When
those units are in their Standby Mode the
Microprocessor’s Circuitry inside each
component is active and communication is
occurring between them. Failure to do so
could result in malfunctioning of some or all
of the system’s normal operations including
the keypads.
2. Connector is available from the
McIntosh Parts Department:
Terminal Block Plug with
five Connections Part No.
117-672
3. For additional connection information,
refer to the owner’s manual(s) for any
component(s) connected to the WK3/WK4
Keypad.
4. Up to four McIntosh Keypads or (Sensors)
can be wired in parallel for each Remote
Zone.
5. A McIntosh WK-3/WK-4 Keypad may be
connected to earlier McIntosh A/V Control
Centers, Multizone Controllers or
Preamplifiers that uses a “F” Coax
Connector instead of the Terminal Block
Socket. It does require the addition of a
12VDC Power Supply for proper operation.
Follow the hookup connections below:
Shielded
Cable
“F” Connector
Keypad External
DC Power
Supply
12 Volts
@50mA
+
-

5
5 Pin Keypad Terminal Connector
When connecting the WK-3/WK-4 Key-
pad with McIntosh A/V Control Centers,
Multizone Controller or Preamplifier uti-
lizing a 5 Pin Terminal Block Connector
Socket and Plug connect as follows:
1. Supply Voltage Positive
2. Supply Voltage Negative
3. Cable Shield
4. Signal Data
5. Signal Data Ground
RJ45 Keypad Terminal Connector
When connecting the WK-3/WK-4 Key-
pad with McIntosh A/V Control Centers,
Multizone Controller or Preamplifier uti-
lizing a RJ-45 Connector Socket connect
as follows:
RJ-45 Socket
1. Signal Data
2. Signal Data Gnd. and Cable Shield
3. N/C
4. Supply Voltage Negative
5. Supply Voltage Positive
6. N/C
7. N/C
8. N/C
Connector Information
6. The WK-3/WK-4 Keypads are designed to
be connected with a “four conductor
shielded cable” or “CAT 5 shielded cable”.
In most installations a non-shielded cable
may be used with the WK-3/WK-4, however
the shielded cable provides the best
immunity from outside interference.
7. The DVD Source Selection Push-button on
the WK-3 and WK-4 Keypads is labeled as
V-AUX on earlier McIntosh A/V Control
Centers, Multizone Controllers and
Preamplifiers.
8. The last production versions of the MX130
(serial number starts with ND1001) and the
C39 (serial number starts with NC1001)
utilize a single terminal block socket with
connections for both Zone A and Zone B.
RJ-45
Keypad
Socket
Pin 1Pin 5
Pin 1 Pin 8
C39/MX130 Rear
Panel
Keypad Socket
Zone A Keypad
Zone B Keypad
Shield
Shield

6
WK-3 and WK-4
Performance Features
Introduction
••
••
•Built-in IR sensor
Adds the convenience of operating a com-
ponent with a remote control in a local
zone.
••
••
•Multiple Inputs
Select any available audio/video source in
a local zone.
••
••
•Local Volume Control
Adjust local zone volume level up or
down.
••
••
•Illuminated Push-Buttons
Input and power push-buttons illuminate to
indicate zone status and selected signal
source.
••
••
•Transport Controls
Perform operating functions on Disc Play-
ers or tape recorders.
••
••
•Wake-up Source and Volume
Select the signal source and volume level
that is active when a zone is turned on.
••
••
•Power Off of Local Zone and System
Turn off a local zone, or turn off the entire
system.
Introduction and Performance Features
The McIntosh WK-3 and WK-4 keypads
allow convenient push-button remote con-
trol of McIntosh A/V Control Centers,
Multizone Controller and Preamplifiers.
••
••
•Built-in Clock and Timer
The clock display indicates the time of
day, as well as the on and off set times of
special events.
••
••
•Preset Timed Events
Enjoy listening to a signal source for a spe-
cific time using the timed event turn on
and turn off feature.
••
••
•Sleep Mode
Set a turn off or sleep time in 10 minute
intervals up to one hour.
WK-4 Performance Features
••
••
•Integrates with the Remote Control
Translator
The Keypads work together with a McIn-
tosh Remote Control Translator to provide
remote operation of non McIntosh Source
components without the bother and ex-
pense of multiple Universal Remote Con-
trols.

7
WK-3 Dimension and Installation
WK-3 Dimension and Installation
WK-3
Mounting
Cutout Detail
The WK-3 can be custom installed in a
wall opening, piece of furniture or cabinet
of your choice. The WK-3 will fit in a
standard NEMA, 1-gang, sheet-steel or
non-metallic outlet box with a depth of 2-
1/2 inches. The WK-3 can be mounted di-
rectly to a wood or plasterboard wall by
making a cutout according to the dimen-
sions shown below. Plastic screw anchors
are supplied for installation in plaster-
board. Make sure the mounting surface is
flat so the keypad does not bend or deform
as the screws are tightened. Do not install
the WK-3 directly above a heat generating
object such as a radiator.
Note: Allow for an additional 1/8 of an inch
(3.2mm) in depth behind the Terminal
Connector for wires.
1-11/16"
43mm
WK-3
Bottom View
2-9/16"
65mm
WK-3
Side View
1-1/2"
38mm
1-5/8"
41mm

8
5-5/16"
135mm
WK-4
Bottom View
2-9/16"
65mm
WK-4
Side View
1-1/2"
38mm
1-5/8"
41mm
WK-4
Mounting
Cutout Detail
The WK-4 can be custom installed in a
wall opening, piece of furniture or cabinet
of your choice. The WK-4 will fit in a
standard NEMA, 3-gang, sheet-steel or
non-metallic outlet box with a depth of 2-
1/2 inches. The WK-4 can be mounted di-
rectly to a wood or plasterboard wall by
making a cutout according to the dimen-
sions shown below. Plastic screw anchors
are supplied for installation in plaster-
board. Make sure the mounting surface is
flat so the keypad does not bend or deform
when the screws are tightened. Do not in-
stall the WK-4 directly above a heat gener-
ating object such as a radiator.
Note: Allow for an additional 1/8 of an inch
(3.2mm) in depth behind the Terminal
Connector for wires.
WK-4 Dimension and Installation
WK-4 Dimension and Installation

9
McIntosh System Controller
1. Connect one end of a shielded 4 con-
ductor cable from the WK-4 Keypad
Connector to the 5-Pin Terminal Con-
nector Plug, refer to adjacent chart
along with pages 4 and 5 of this
manual. Connect the 5-Pin Terminal
Connector Plug to the Zone 1 5-Pin
Terminal Block Connector of the
McIntosh System Controller.
Note: Refer to “Important Information”
number 5 and 8 on page 5 when
connecting the keypads to a C39
or MX130. If the Keypad is used
in the same room as the System
Controller, it is important to
disable the Front Panel Sensor on
the Controller to prevent
interference.
Refer to the
System
Controller
Owner’s Manual
for additional
information.
How to Connect with the 5-Pin Terminal Connector
Keypad
Connecti on
Num ber
5-Pin Plug
Connection
Numbe r
Wire
Color
11
22
33
44
55
Keypad Connections
How to Connect with the 5-Pin
Terminal Connector
2. Connect the WK-3 Keypad in a similar
manner as above except connect the 5-
Pin Terminal Connector Plug to the
Zone 2 5-Pin Terminal Block Connec-
tor of the McIntosh System Controller.

10
Keypad
Connecti on
Num ber
RJ45 Plug
Connection
Num ber
Wire
Color
15
24
32
41
52
Keypad Connections
McIntosh A/V Controller
1. Connect one end of a shielded 4 con-
ductor cable from the WK-3 Keypad
Connector to the RJ45 Connector
Plug, refer to adjacent chart along with
page 5 of this manual. Connect the
RJ45 Plug to the Zone A RJ45 socket
of the McIntosh A/V Controller.
Note: If the Keypad is used in the same
room as the System Controller, it
is important to disable the Front
Panel Sensor on the Controller to
prevent interference. Refer to the
A/V Controller Owner’s Manual
for additional information.
How to Connect with the RJ45 Connector
How to Connect with the RJ45
Connector
2. Connect the WK-4 Keypad in a similar
manner as above except connect the
RJ45 Plug to the Zone B RJ45 Socket
of the McIntosh A/V Controller.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali McIntosh Tastiera