Mect TP1043 02 series Manuale utente

ME7056_07
10/18
USER’S MANUAL
TP1043 02 series
HMI –Operator panel


HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
INDEX
1. Introduction.............................................................................................................. 1
1.1. Staff skill............................................................................................................ 1
1.2. Simbols............................................................................................................... 1
1.3. Terms ................................................................................................................. 2
1.4. Security .............................................................................................................. 2
1.5. REFERENCE MANUAL.................................................................................. 2
2. System description................................................................................................... 3
2.1. Specification....................................................................................................... 4
3. Mechanical dimensions ........................................................................................... 5
3.1. Panel mount........................................................................................................ 8
3.1.1. Distance........................................................................................................ 8
4. TP1043 02 wiring.................................................................................................... 9
4.1. Connections........................................................................................................ 9
4.2. Power supply...................................................................................................... 9
4.2.1. Insulation...................................................................................................... 9
4.2.2. System power supply ................................................................................... 9
4.2.3. Fuse ............................................................................................................ 10
4.3. ModBus wiring ................................................................................................ 10
4.4. CANOpen wiring.............................................................................................11
5. Peripherals .............................................................................................................12
5.1. USB.................................................................................................................. 12
5.2. Ethernet............................................................................................................ 12
6. HMI........................................................................................................................ 13
6.1. System variables .............................................................................................. 13
7. How to order.......................................................................................................... 13

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
1
1. Introduction
To grant a fast setup of the device please follow carefully the information in this
manual.
1.1. Staff skill
Products described in this manual are devoted to PLC programmers or automation
experts only. MECT S.r.l. declines any responsibility about malfunctioning or
damage caused by incorrect use of MECT devices, due to noncompliance to this
manual information. MECT S.r.l has an help desk.
1.2. Simbols
Danger
Follow this advice to avoid people injury.
Warning
Follow this advice to protect the device.
Caution
Follow this advice to have a more effective performance.
ESD ( Electrostatic discharge)
Danger: possibly damage due to Electrostatic discharge.
Note
Step to follow for a correct installation.
Additional information

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
2
1.3. Terms
PLC: TP1043 02
Terminals: MPNC005, MPNC010, MPNC020, MPNC030, MPNC035
System: PLC (TP1043 02) with terminals
1.4. Security Attention
Switch off devices before connecting them.
ESD (Electrostatic discharge)
Modules have electronic components that can be damaged by.
electrostatic discharge. Be sure to be connected to ground when
handle the devices.
The instrument has no power switch and no internal fuse, but it powers on
immediately after connecting a correct power supply input (check the power supply
value on the instrument label). Keep the power supply line as short as possible and
keep it separate from other power lines.
For security reasons it is necessary to have a 2 section power switch with a fuse near
the instrument and easily replaceable.
Avoid the presence of other power actuators in the same control panel, high humidity,
excessive heat and corrosive gas.
Instruments must have a power supply from security transformers or SELV
transformers.
1.5. REFERENCE MANUAL
The Quick Start (downloadable from the web site)
and MectSuite Tutorial are the reference manuals for
MectSuite to develop HMI and PLC applications.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
3
2. System description
TP1043 02 is a device composed by a PLC and a HMI with touch-screen monitor
4.3” width and 480 x 272 pixel resolution with 262.000 colors.
TP1043 02 allows the supervision of networked devices Modbus RTU and Modbus
TCP. The networks are managed simultaneously by TP1043 02 and data from a
network can be sent on another thus creating a bridge between the two networks.
On TP1043 02 is present Micro-USB host port, that allows, with an adapter, the use
of an USB-pen drive for software updates and data log.
On TP1043 02 are up to 1 Kbyte of retentive variables stored on flash.
The device is also able to manage an up to 64GB wide, micro SD card. The SD card
is factory mounted on request.
A real-time clock buffered RAM maintains the date and time up to four months with
the device turned off.
TP1043 02 is equipped with a micro PLC to make a small automation of the process.
The device can be applied in horizontal or in vertical design with the option "V" (see
following pictures).
Figure 1: Front view TP1043 (horizontal version)
Figure 2: Front view TP1043 (vertical version)

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
4
2.1. Specification
TP1043 02 is based on a multiprocessor system. PLC and HMI are based on a
454MHz ARM9.
Table 1
Hardware characteristics
PLC Processor
ARM926JE 454MHz
RAM
128MB
FLASH
128MB
Non volatile variables
On FLASH memory
Real Time Clock
Yes with rechargeable battery
Screen
TFT 480 x 272 pixel 262k colors
Touch screen
Resistive 4 wires
Ethernet
10Mbit/s - 100Mbit/s self recognition
Micro-USB
Host 2.0
Micro SD
Max 64GB
Software characteristics
OS
LINUX 2.35
PLC
IEC61131-3
Graphics
Based on QT library
CAN
CanOpen 2.0
ModBus
Modbus RTU master
Storage memory
Possibility of history storage
Field bus main features
RTU Modbus
Master 2 wires
TCP Modbus
Client
Power supply
Power Supply 24VDC
12÷36Vdc - 150mA (24Vdc)
Power Supply 24VAC
24Vac ±20% - 150mA
Electromagnetic compatibility
The electromagnetic compatibility tests have been carried out at accredited
laboratories, acc ording to EN 61326-1, EN 61131-2 and EN 61000-6-2standards.

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
5
3. Mechanical dimensions
In the following figures see the TP1043 dimensions.
Panel with frame mounting and hooks fastening:
Encumbrance
Front view Side view
Mounting plate

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
6
Panel with frame mounting and screws fastening:
Encumbrance
Front view Side view
Mounting plate

HMI - Operator panel: TP1043 02 Mect srl
ME7056_07 10/18
7
Panel without frame mounting:
To mount it is necessary that the display is at the same panel height, so for metal
panels below 2,5mm it is necessary to insert a shim to reach the exact quote.
Front view Side view
Technical specification
Table 2
Mechanical
Material
ABS, Polycarbonate
Dimensions W x L x H
27 mm x 156 mm x 80 mm
Mounting plate
127mm x 68mm
Installation
Panel installation
Environmental conditions
Operative temperature
0 °C ... 55 °C
Storage Temperature
-20 °C ... +85 °C
Relative Humidity
5 % a 95 % no condensation
Electric isolation
Air clearance
According to IEC 60664-1
Pollution
According to IEC 61131-2
2
Protection
Rear protection
IP 20
Front protection
IP65
Attention
Install the device in a panel with no more than 55 °C.
Altri manuali per TP1043 02 series
1
Indice
Altri manuali Mect Pannello di controllo