3en_LITC2Ux2_V.00
1) Tap the mode button to select ‘Alm Vs Tgt ’ mode.
1)
5)
4)
2)
3)
Free target temp. curve
Alarm:L(0)H(2)
5)
19 20
14. How to set ‘Alm Vs Tgt.’ and ‘Alm Vs Obj.’ data logging
2) Move the ‘Free target’ pointer on screen to record target temp.
In the upper left corner of the operating interface is the number of alarms, and the
number of alarm records in parentheses. L ( Low ) is low temp. alarm, H ( High )
is high temp. alarm. The recording interval is 1 time per minute ( if it occurred
multiple times in 1 minute, it will only record once ). The number of times the
alarm record could be recorded depends on the capacity of the Smartphone.
NOTE : Recorded photos can be viewed inside ‘Photo Album’ or ‘File Management’
of the Smartphone.
45.0
25.0
999.920.0
40.0
-20.0
3) Read the current ‘target’ temperature, such as 31.5°C.
‘Low’ alarm
temp. level
‘High’ alarm
temp. level
1)
2)
‘Low’ alarm
temp. level
‘High’ alarm
temp. level
a) ‘Low’ temp. alarm
value setting
1) Tap the mode button to select ‘Alm Vs Obj. ’ mode.
Alarm:L(1)H(1)
3)
In the upper left corner of the operating interface is the number of alarms, and
the number of alarm records in parentheses. L ( Low ) is low temperature alarm,
H ( High ) is high temp. alarm. The recording interval is 1 time per minute ( if it
occurred multiple times in 1 minute, it will only record once ). The number of times
the alarm record could be recorded depends on the capacity of the Smartphone.
45.0
25.0
999.920.0
40.0
-20.0
2) There are three options to set up the temp. alarm range :
b) ‘High’ temp. alarm
value setting
a) ‘Low’ temp. alarm
value setting
c) ‘High’ and ‘Low’
enter both alarm
temp. value
Blue curve
indicates
‘Low’ temp.
Red curve
indicates
‘High’ temp.
3)
4) There are three options to set up the temp. alarm range :
a) Low temp. alarm
If only low temp. alarm is required, please input the max. value ‘999.9’ in the high
temp. alarm column. For example, when the temp. is lower than 20°C to alarm,
enter ‘20.0’ at the low temp. alarm column, as shown below :
b) High temp. alarm
If only ‘high’ temp. alarm is required, please input the min. value ‘- 20.0’ in the low
temp. alarm column. For example, when the temp. is higher than 40°C to alarm,
enter ‘40.0’ at the high temp. alarm column, as shown below :
c) High and low temp. alarm
For ‘high’ temp. alarm and ‘low’ temp. alarm at the same time during detection, just
input the corresponding values in the high temp. and low temp. alarm column. For
example, when the alarm is below 25°C and the alarm is above 45°C, input as
shown below :
NOTE : Recorded photos can be viewed inside ‘Photo Album’ or ‘File Management’
of the Smartphone.
b) ‘High’ temp. alarm
value setting
c) enter both alarm
temp. value
a) Low temp. alarm
If only low temp. alarm is required, please input the max. value ‘999.9’ in the high
temp. alarm column. For example, when the temp. is lower than 20°C, it will alarm,
enter ‘20.0’ at the low temp. alarm column as shown below :
b) High temp. alarm
If only high temp. alarm is required, please input the min. value ‘- 20.0’ in the low
temp. alarm column. For example, when the temp. is higher than 40°C, it will alarm,
enter ‘40.0’ at the high temp. alarm column as shown below :
c) High and low temp. alarm
If there is a high temp. alarm and low temp. alarm at the same time during detection,
just input the corresponding values in the high temp. and low temp. alarm column.
For example, when the alarm is below 25°C and the alarm is above 45°C, input as
shown below :
20.0 39.5
20.0 39.5
A) ‘Alm Vs Tgt.’ Record ‘Target’ alarm temp.
How to set ‘Alm Vs Tgt’ mode ?
Introduction :
‘Free target’ temp.
reading display
Alarm setting for
‘Low’ temp.
How to set ‘Alm Vs Obj’ mode?
Introduction :
Alarm setting for
‘Low’ temp.
Alarm setting for
‘High’ temp.
Auto capture
full screen
information
User can freely move ‘Free target’ pointer
on screen intended to record on any target
object. The image sensor automatically snap
the whole picture recorded once the alarm
triggered. Users can use this unique function
for the following application scenarios:
‘Free target’ pointer can
be freely move to any object
or surface to aim that
temp. for alarm purpose
Alarm setting for
‘High’ temp.
B) ‘Alm Vs Obj.’ Record ‘Object’ alarm temp.
Auto capture
full screen
information
In this ‘Alm Vs obj.’ alarm data logging mode,
user can record either ‘High’ / ‘Low’ / ‘High’ and
‘Low’ alarm temp. on any object or space / location
within Visible image screen.
The thermal sensor scan and trace temp. on
object ; space / location every second. Once
presetted alarm temp. range exceeded, the thermal
sensor will automatically snap the whole screen
picture with full information and save it in the
Smartphone. User can use this unique function for
the following applications :
20.029.5
20.0 29.5
- Inside electrical panel, used to monitor or record /
trouble shooting of Wires / Cables; Fuse / RCD /
MCB ; Busbar / Link / Joint Connection; Contacts
of Magnetic Contactor; etc.
- Inside Electronic equipments, find out temp. rise of
electronic components on PCB; UPS; Invertor etc.
- HVAC ; Refrigeration; Plumbing; Mechanical; Machine;
Industrial; Building automation; Agriculture; Laboratory;
Warehouse etc. used to monitor / record / analysic.
- Large area monitor of food storage, such as frozen
food; Wines; chilled drinks as well as temp.
controlled chamber.
- Large area monitor water leakage on floors / walls /
basement; under ceiling.
- Air leakage of doors; windows; etc.
- For electrical or mechanical they can check
and monitor the temperature rise of Wires /
Cables; Busbar; Magnetic Contactor; Fuse;
Circuit Breaker; Junction Connection; AC
Motors etc.
- HVAC / Plumbing / Air-Conditioning
measures and record High / Low temp. ;
Hot / Cold water ows; status of air duct /
ventilation etc.
- Catering, food processing; thermal leakage
of chilled chamber
- Water leakage on walls; oors; ceiling;
basement, monitoring water / air steam
restoration, etc.