INSTALLATION
Preparing for Installation
♦Turn OFF all power to the vending machine.
♦To ensure that the CF7000 performance is not
affected, visually check the vending machine is
upright, both from the front and side.
♦Before mounting the CF7000 to the vending
machine, check the operating voltage of the vending
machine matches that stated on the CF7000 label.
Installing the CF7000 to the machine
The CF7000 is mounted onto the vending machine by hanging it onto three studs
located on the vending machine. To do this you will need to open the
discriminator assembly and line up the mounting keyholes of the CF7000 with the
vending machine studs.
♦Press the yellow button at the top of the CF7000 and gently lift and pull the
discriminator assembly forward. Once open, the mounting keyholes will be
made visible.
♦To securely fix the CF7000 in place, partly unscrew the three machine studs.
♦Line up the three mounting keyholes of the CF7000 with the studs and hang it
in place ensuring that the CF7000 is sitting flat against the machine back
plate.
Label

Page 3 of 10
♦Tighten all three studs and return the discriminator back to its normal position.
Alignment Checks
Once the CF7000 has been securely fitted to the vending machine, check reject
lever operation and coin chute alignment. Do this without any power applied to
the machine.
Cable Connection
The CF7000 may be fitted with more than one cable,
these may be intended for TX-RX communications,
drive an external display or to extract audit data.
Once all relevant cables are connected and before
closing the machine door, tuck any unused cables
away tidily ensuring that none are trapped between
the reject lever mechanism and the vending
machine door. You can now switch ON the power to
the vending machine.
4mm
Lid
Lever
Reject
Button
Check there is a minimum 4mm gap between
the machines reject lever mechanism and the
CF7000 reject button.
Press the machine lever a couple of times and
ensure the lid of the discriminator opens and
closes correctly.
Check machine coin chute alignment by inserting
two of each coin denomination through the coin
entry slot of the machine.
Ensure that the inserted coins fall freely into the
CF7000 and exit out into the machines cash
return cup.

Page 4 of 10
KEYPAD FUNCTIONS
On the front of the CashFlow
®
7000 there is a user interface keypad. The keypad
has three LED’s, six function buttons, and depending on the CF7000 model a
large LCD display.
This keypad allows you to dispense coins from the five-tube dispenser, access &
navigate through the configuration menus and monitor the status of the CF7000.
CF7400 CF7900
1 3 LED’s Red, Amber, Green
2 to Dispense coins & navigate through menus
3 Display (LCD) Menu information & warning display
4 ‘Mode’ Button Access service & setup menus
5 Service Connector CPM Compatible
The LED’s provide a visual indication by light flashes that report the state of the
CF7000. An LED can either be ON, OFF or FLASHING. These light flash codes
can indicate when the CF7000 is operating normally, is in configuration/program
mode or has a fault.
(Refer to the LED light code section for more information)
The blue keys (marked A to E) have two functions.
When the CF7000 is in idle mode, pressing a blue button on its own will dispense
a coin from that tube. When you press and hold the blue button for approx. 4
seconds, this activates auto dispense (latch dispensing of coins) until the tube is
empty of coins. If however, the yellow (mode) button is pressed, the blue buttons
are then used for navigation through the CF7000 service mode and setup mode
menus.
(Setup menus are only available on CF7900)
Service Mode: gives access to the most frequently used product configuration
options.
(See Service Mode Options - Page 6)
Setup Mode: gives access to general product configuration options that are
required when setting up your CF7000.
(See Setup Mode Menus - Page 7)
1
2
5
4
3
A E
1
2
5
4

Page 5 of 10
GETTING STARTED
At power up, the CF7000 will run a self test, where the CF7000 motor will sound,
the LED’s will cycle five times through a sequence of red, amber & green.
On CF7900 the LCD display briefly shows its software revision and as there are
no coins in the tube cassette, the display will show a “Low Tubes” message
requesting that the coin tubes be filled to a predefined level (
refer to the floating coin
tubes section
). Once the CF7000 has enough coins in the tubes, the LCD display
will show the coin totals (in currency value) stored in the tubes.
Note: MEI recommends that a small number of coins (e.g. 5 of each) be inserted
in each tube prior to leaving the machine.
Floating the Coin Tubes
There are two ways to float the CF7000 tubes with coins.
1) Manually fill each tube by inserting coins into the tubes.
2) Use the Service Mode and insert coins through the discriminator.
Filling Tubes Manually
1. Remove the tube cassette from the CF7000.
2. Insert required number of coins into relevant storage tubes.
3. Re-fit tube cassette back on to the CF7000.
The CF7000 will now begin an automatic tube calibration measurement where a
clicking sound will be heard, this is normal. On CF7900 once calibration is
complete the display will show a total currency value of the coins inserted. If a
tube is left empty the display will show a tube low message for the particular tube.
Fill Tube using Service Mode
1. Press the Yellow ‘Mode’ button once.
2. Press ‘A’ button and start inserting coins through the discriminator.
3. On CF7900 the display will show the number of coins that are required for
each tube. (the displayed count will decrement as coins are inserted)
4. Press ‘A’ button to exit float mode.
CF7000 Menu Structure
(CF7900 only)
Setup Mode
There are two ways to access the Setup Mode menus.
1. Press and hold the ‘Mode’ button for 2 seconds.
2. Press the ‘Mode’ button once and select the ‘Setup’ option by pressing
button ‘E’. (This method requires a pass code. When asked for this, press
buttons ‘A’‘B’‘C’).

Page 6 of 10
*
Service Mode Options (Quick Menu Codes)
This list shows the most commonly used service modes.
Press Following
Button Sequence Description /
Action
Float coin tubes / (Insert coins then press ‘Mode’
button)
Clear accumulated credit – (Not MDB) and clear
‘Clean Me’ message.
[‘Clean Me’ message not shown on CF7400]
Float Teach sets float levels to current coin tube
levels.
[Not available in Auto Float mode]
Inhibit a coin / (Insert a coin and then press the reject
lever)
Enable a coin / (Insert a coin and then press ‘Mode’
button)
View coin details / (press to scroll up)
(press to scroll down)
View channel set / (press to exit view)
Teach vend price / (Insert coins to the value of
the price and then press the price line button on
the machine to set it)
(When finished press the button)
[This feature is only available on Executive products]
Custom tube cassette teach /
(Enter coin, select position then press )
Select predefined tube cassette / (enter code on
cassette label & press ‘Mode’ button)
Features only available on CF7900
D ? ?
D
C
C
C
D
B B
B A
B
B
A D
A A
A
*
*
*
*

Page 7 of 10
Setup Mode Menus
(not available on CF7400)
Menu Starts from Here
Prices
Language
Float Options
Change Mgmt
Machine Options
Coin Config
Cashless Config
General
Error Log
Test
Audit Config
Bank Note Config
Menu Option Selected
Press button ‘D’ - Scrolls Up the menus
Press button ‘E’ – Scrolls Down the menus
EXAMPLE: - How to set the language
1. Press the ‘Mode’ button once
2. Press button ‘E’ to select ‘Setup’
3. Enter pass code, Press ‘A’‘B’‘C’
4. Press button ‘D’ to scroll up the menu
an until the display shows Language
5. Press ‘Select’ then ‘Edit’
6. Use button ‘D’ or ‘E’ to scroll to the
required language
7. Select ‘OK’
8. Select ‘Back’ and ‘Back’ again to
save your setting and exit
Messages Only if Messages available

Page 8 of 10
General LED Light Codes
On - CF7000 OK.
Cycles x 5 - Normal power up sequence.
CF7000 OK.
Blinks Off - Coin accepted / rejected.
Flashing - CF7000 in Menu mode
On – CF7000 inhibited by VMC.
Flashing - CF7000 requires attention.
(Refer to Amber LED light codes)
Off - No Power to CF7000.
(Check power looms are connected & ensure
power is switched ON)
Alternating - CF7000 Faulty
(Remove from vending machine)
Amber LED Light Codes
If the amber LED flashes, this indicates that a fault has been detected on one of
the CF7000 main modules. These types of fault can be rectified at the machine
and can be for example caused by; a coin jam; dirt built up; or the cassette has
been removed etc. The CF7000 will also indicate the module affected on its
display.
Flashes Check CF7000 Module
1 x Discriminator
2 x Accept gate
3 x Separator module
4 x Dispenser module
A
G
A
G
A
R
R
G
G
A
A
A
A
G

Page 9 of 10
Selecting Predefined Cassette
The CF7000 has stored in memory a selection of predefined tube cassettes that
provide different payout options. (See table below).
By pressing the correct button code on the keypad you can select the required
payout option.
The correct button sequence code can also be found on the front label of the
cassette.
To select a predefined cassette, press the ‘Mode’ button then ‘D’ followed by the
button code.
Finally select ‘Accept’ from the menu to confirm and save.
Button
Code Tube A Tube B Tube C Tube D Tube E
AA 5c 10c 50c 20c 5c
AB 1c 10c 50c 2c 5c
AC 5c 10c 50c 20c 1
AD 5c 10c 50c 10c 1
AE 5c 10c 50c 10c 5c
BA 10c 10c 50c 10c 1
BB 10c 10c 50c 20c 1
BC 20c 10c 50c 12
BD 1 - 50c 12
BE 1 - 50c 22
CA 1c 10c 50c 1 5c
CB 20c 10c 50c 1 20c

Page 10 of 10
SAFETY
National & International Standards Conformance
CashFlow
®
7000 Series products operate at Safety Extra Low Voltage Level
(SELV) as defined in IEC335/EN60335 ‘Safety of Household and Similar
Appliances’. They may be designed into equipment complying with
IEC335/EN60335 or IEC950/EN60950 ‘Safety of Information Technology
Equipment’.
CashFlow
®
7000 Series products are of Class 3 construction.
Rated Operating Voltage
The operating voltage of a CashFlow
®
7000 Series is stated on the label attached
to the product. It must not be used with any power source other than that
indicated.
Dangerous Environments
The CashFlow
®
7000 Series must not be operated in the presence of flammable
gasses, fumes or water.
Product Disposal
Do not dispose of any part of a CashFlow
®
7000 Series by incineration.
CashFlow
®
7000 Series Start-Up Guide
Revision G3
Publication Date: August 2006
Internet: http://www.meigroup.com
MEI
®
, CashFlow
®
and the MEI device are registered
trademarks. Copyright MEI UK International Ltd. 2006.
Altri manuali per CASHFLOW 7000 Series
2
Questo manuale è adatto per i seguenti modelli
3
Indice
Lingue:
Altri manuali MEI Cambiamonete
Manuali Cambiamonete popolari di altre marche

American Changer
American Changer AC6007 Manuale utente

American Changer
American Changer AC2007 Manuale utente

Coinco
Coinco vortex Istruzioni operative originali

American Changer Corp.
American Changer Corp. AC401-2 Guida all'installazione

Coinco
Coinco Guardian 6000 Manuale utente

Comestero
Comestero Suzohapp Multi PRO Manuale utente