MeiTrack T366G Manuale utente

MEITRACK A91 Passenger Flow Sensor User Guide
MEITRACK A91 Passenger Flow Sensor
User Guide
Applicable Model: T366G

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 2 -
Change History
File Name
MEITRACK A91 Passenger Flow Sensor User Guide
Applicable Firmware
T366G_Y15V216
Creation Date
2019-02-12
Subproject
Accessory User Guide
Total Pages
17
Version
V1.0
Confidential
External Documentation

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 3 -
Contents
1 Copyright and Disclaimer........................................................................................................................................... - 4 -
2 Product Introduction ................................................................................................................................................. - 4 -
2.1 Product Functions......................................................................................................................................... - 4 -
2.2 Function Description..................................................................................................................................... - 4 -
3 Main Device and Accessories .................................................................................................................................... - 5 -
4 Product Specifications ............................................................................................................................................... - 6 -
5 Installation................................................................................................................................................................. - 7 -
5.1 Connecting the A91 to the T366G ................................................................................................................ - 7 -
5.2 Installing the A91.......................................................................................................................................... - 7 -
5.2.1 Installing the Passenger Counter ......................................................................................................... - 7 -
5.2.2 Installing Extension Cables................................................................................................................... - 8 -
5.2.3 Installing the Door Opening and Closing Signal Cable ......................................................................... - 8 -
5.2.4 Installing Cameras.............................................................................................................................. - 10 -
5.2.5 Installing All Parts............................................................................................................................... - 11 -
6 A91 Debugging ........................................................................................................................................................ - 12 -
6.1 A91 Running Status..................................................................................................................................... - 12 -
6.2 APC Assistant Debugging Tool..................................................................................................................... - 12 -
6.3 Adjusting the Angle of Cameras.................................................................................................................. - 14 -
7 Configuring the A91 on Meitrack Manager ............................................................................................................. - 14 -
7.1 Selecting a Peripheral ................................................................................................................................. - 14 -
7.2 Setting the GPRS Event ............................................................................................................................... - 14 -
8 Clearing the Counter................................................................................................................................................ - 15 -
8.1 Clearing Method......................................................................................................................................... - 15 -
8.2 Setting A91 Parameters – BAE .................................................................................................................... - 15 -
9 Querying Reports from the MS03 Platform............................................................................................................. - 16 -
9.1 Querying Passenger Counter Reports......................................................................................................... - 16 -
9.2 Querying Alert Reports............................................................................................................................... - 17 -

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 4 -
1Copyright and Disclaimer
Copyright © 2019 MEITRACK. All rights reserved.
, and are trademarks that belong to Meitrack Group and its subsidiary.
The user manual may be changed without notice.
Without prior written consent of Meitrack Group, this user manual, or any part thereof, may not be reproduced for
any purpose whatsoever, or transmitted in any form, either electronically or mechanically, including photocopying
and recording.
Meitrack Group shall not be liable for direct, indirect, special, incidental, or consequential damages (including but
not limited to economic losses, personal injuries, and loss of assets and property) caused by the use, inability, or
illegality to use the product or documentation.
2Product Introduction
2.1 Product Functions
⚫Count the number of passengers entering or leaving a vehicle from the front or back door
⚫Count the total number of passengers entering or leaving a vehicle from the front or back door
⚫Count the number of remaining passengers inside a vehicle
⚫Front/back door camera occlusion alert
⚫Front/back door camera recovery alert
⚫Front/back door camera abnormal alert (camera disconnected)
⚫Front/back door camera normal alert (camera connection normal)
2.2 Function Description
Based on the machine vision technology, the A91 passenger flow sensor collects passengers' head and shoulder
information by the non-contact model and automotive image sensor. After receiving a door opening signal, the
passenger counter starts to count the number of passengers entering and leaving a vehicle by the pattern recognition
technology. After the doors are closed, the T366G vehicle tracker will upload the number of passengers and
positioning information to the back-end server and platform, which implements statistical analysis of the number of
passengers at each station and along each driving route, and provides accurate data for the route configuration and
vehicle dispatching. The unit can be installed into buses, subways, trains, ships, shopping malls and buildings.

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 5 -
3Main Device and Accessories
Name
Quantity
Picture
Passenger counter
1
Camera
2
Main wire harness
1
Power cable
1

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 6 -
Door opening and closing
signal cable
2
Extension cable with 4-pin
aviation connectors (15
meters)
2
Used to connect cameras to the passenger counter.
Extension cable with 4-pin
aviation connectors (8
meters)
2
Used to connect the door opening and closing signal cable
to the passenger counter.
4Product Specifications
Item
Description
Passenger counter weight
600g
Passenger counter dimension
200.3 mm x 146.5 mm x 41.3 mm
Passenger counter voltage
9–36 V DC (recommended: 24 V)
Passenger counter current
300 mA
Passenger counter power
7.56 W (input voltage: 24 V)
Camera dimension
38 mm x 38 mm
Camera voltage
12 V
Camera current
40 mA (day); 140 mA (night)
Camera power
0.84 W (day); 3.24 W (night)
Operating temperature
-40°C to 85°C
Operating humidity
0%–95%
Baud rate
115200 bps
Passenger flow speed
< 10 m/s (If the speed is lower than 2 m/s, the accuracy is higher.)
Counting accuracy
92%

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 7 -
5Installation
5.1 Connecting the A91 to the T366G
T366G
A91
Power supply
Power supply
GND
GND
RS232 TX
RS232 RX
RS232 RX
RS232 TX
5.2 Installing the A91
5.2.1 Installing the Passenger Counter
The installation location varies depending on vehicle types. It is recommended that the passenger counter should be
installed behind the driver's seat, be kept away from the humid environment, and be placed in an iron cabinet to
prevent unauthorized personnel from touching it. In addition, the counter needs to be connected to the main wire
Rear view of the passenger counter:
Note: At present, we can use the power interface and main wire harness interface of the passenger counter, while
other interfaces are reserved.
The passenger counter needs to be connected to the 12 V/24 V DC power supply and connected to the cameras,
vehicle doors and T366G's RS232 interface by the main wire harness (labelled with wiring instructions). When the
counter detects that a vehicle door is open, it will start counting. When the counter detects that a vehicle door is
closed, it will stop counting and upload statistical results to the server. The following table describes the DC power
cable and main wire harness:
Interface
Wiring
Description

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 8 -
DC power
cable
Power cable (red)
The input voltage is 12 V or 24 V. It is used to supply power to the A91.
GND (black)
Connect to the GND wire.
ACC (yellow)
Connect to the ACC cable. When the passenger counter detects that
the ACC is off, there is a delay of five minutes and it will automatically
enter the sleep mode. When the ACC is on, it will enter working mode
again, which ensures counting accuracy and reduces power
consumption.
Main wire
harness
Camera (front door)
Connect to the camera at the front door through the extension cable
with 4-pin aviation connectors (15 meters).
Camera (back door)
Connect to the camera at the back door through the extension cable
with 4-pin aviation connectors (15 meters).
Front door opening and
closing signal cable
Connect to the front door opening and closing signal cable through
the extension cable with 4-pin aviation connectors (8 meters).
Back door opening and
closing signal cable
Connect to the back door opening and closing signal cable through
the extension cable with 4-pin aviation connectors (8 meters).
RS232 peripheral
Connect to the TX (red), RX (blue) and GND (black) interfaces of the
T366G.
RS485 peripheral
Reserved
5.2.2 Installing Extension Cables
Extension cables are used to connect cameras to the passenger counter, and the door opening and closing signal
cable to the passenger counter.
It is recommended that concealed wiring should be done, for example, through the vehicle's ventilation pipes. Do
not expose extension cables to the outside. The ventilation pipes of each door have a set of extension cables. One of
the extension cables is connected to cameras, and the other is connected to the door opening and closing signal
cable. Extension cables are labelled with wiring instructions to avoid wrong wiring.
5.2.3 Installing the Door Opening and Closing Signal Cable
Install the 3-pin door opening and closing signal cable listed in the accessories. The pin definitions are shown in the
following figure:

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 9 -
The opening and closing of most vehicles' doors are controlled by an air valve. The control cable of the air valve has
three pins, that is, opening the door, closing the door, and GND, which correspond to the three pins of the door
opening and closing signal cable. Pull out the 3-pin connector of the air valve control cable, and connect the male
and female connectors on both ends of the cable to the male and female connectors on the door opening and closing
signal cable, as shown in the following figure:

MEITRACK A91 Passenger Flow Sensor User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 10 -
5.2.4 Installing Cameras
Each camera needs to be installed at the front and back doors. The distance that cameras are above the ground of
the vehicle is about 2.2 meters. Meanwhile, the cameras need to be installed in the middle of the upper part of the
doors and are about 0.5 meters away from the glass door (A ≈ 0.5 meters, as shown in the following figure).
Altri manuali per T366G
1
Indice
Altri manuali MeiTrack Accessori