Mendip Stoves Ashcott Guida

Balanced Flue Gas Stoves
Ashcott, Ashcott with logstore
INSTALLATION, SERVICING
AND USER INSTRUCTIONS
For use in GB & IE (United Kingdom and Ireland)
This appliance has been tested and certified for other counties (see technical data). However to install appliance in other
countries, modification of the appliance and its method of installation may be necessary in order to use the appliance safely and
correctly. The manual for the local language must be obtained. Contact Mendip for further information.
Document No. : xxxxxxx –IssDraft 2nd Jan 2019
File: User_Ashcott_BF.doc
OPERATION AND INSTRUCTION MANUAL

GB & IE
2
This produst has been tested, and certified for use on Biopropane Gas.
Biopropane Gas can be used as a fuel, with no adjustment necessary if the product is installed as an LPG
version.
This Manual covers the following Products: Ashcott, Ashcott with Logstore
Mendip stoves Warranty
Each Mendip stove is designed and built with great care, using quality materials. Ensuring the quality of our
product is an integral part of the production process. Your stove comes with a 1 year warranty on
manufacturing defects; this can be extended to 5 years against manufacturing defects if your stove is
purchased through a registered Mendip Stoves retailer and installed by a qualified GAS SAFE installer. The 5 year
extended warranty will only apply if we have received the completed registration card within 1 calendar month
of the purchase of your appliance.
Register online today to activate warranty: www.mendipstoves.co.uk/SIT/StoveRegistration
Please see the Warranty Card for the complete terms and conditions.
HEALTH AND SAFETY PRECAUTIONS
INFORMATION FOR THE USER, INSTALLER AND SERVICE ENGINEER
Special care must be taken when installing a stove such that the requirements of the Health & Safety at Work
Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of
contact wash immediately with plenty of water.
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance. There must not be an
extractor fan fitted in the same room as the stove because this can cause the stove to emit fumes into the
room.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation,
then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal injury.
CO Alarms:-
Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is
installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further
guidance on the installation of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm
manufacturer’s instructions.
Provision of an alarm must not be considered a substitute for either installing the appliance correctly or
ensuring regular servicing and maintenance of the appliance and chimney system.
Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit stove. Be sure to allow aerosols
spray paints to dry and ventilate the room well before lighting the stove. The use of any aerosol around lit
stove is dangerous and care must be taken in handling aerosols.

GB & IE
3
Content
1. General Notes 4
2. User instructions. 5
2.1 Emergency Gas Isolation 5
2.2 First Time of Operation 5
2.3 Control Overview 6
2.3.1 Basic Manual Control 6
2.3.2 Remote Control 8
2.4 Manual Turn OFF 14
2.5 Cleaning and Maintenance 14
3. Installation instructions. 15
3.1 Gas Connection 15
3.2 Ventilation 15
3.3 Appliance Fireplace Installation 15
3.4 Flue Connection 16
3.5 Fuel Bed Arrangements 32
3.6 Commissioning the appliance 36
4. Servicing 37
4.1 Cleaning the Ceramics 37
4.2 Servicing the Burners 37
4.3 Spare parts 38
5. Technical Information 39
5.1 Countries of Use 39
5.2 Technical Data 40
5.3 Dimensions 41

GB & IE
4
1. General Notes
This Mendip gas appliance is a High Efficiency, Balanced Flue Live Fuel Effect appliance. It provides radiant and
convected heat using the latest burner technology. As well as having a variable heat output, these fires also
utilise a special control system that allows the appliance to use three burners for high output or a single burner
for lower outputs.
The Front Burner will be designated as the "Main" Burner, the second, rear burner, will be designated as the
"Effect" Burners. The Effect burner can be switched ON or Off whilst the appliance is alight.
Before Installation, check that the local distribution conditions, nature of the gas and pressure, and adjustment
of the appliance are compatible.
This appliance is intended for use on a gas installation with a governed meter.
This Gas Installation may only be installed by a registered professional competent person (Gas Safe installer
in the UK). The installation must adhere to the requirements of the local and national Building regulations and
national standards. The installation manual must also be followed.
Ensure that the Flue Terminal is not in any way obstructed and is clear of vegetation, i.e. trees, shrubs etc. and
that no objects are leant against the terminal or guard.
Always clean the Window Panel before the fire is ignited. Any finger prints must be removed, as these will be
burnt into the glass and will be un-removable.
Do not operate this appliance if the glass panel has been broken (or cracked), removed or is open.
The appliance is designed to fit numerous installation situations as listed in these installation instructions.
However only flue approved by Mendip for this appliance may be used.
This appliance is a balanced flue product and is room sealed and as such requires no additional ventilation for
operation. However an adequate supply of fresh air to maintain temperatures and a comfortable environment is
recommended.
This appliance is designed as a heating appliance, and as such will get very hot in operation; all surfaces (except
the controls and access door) are considered to be working surfaces and as such should not be touched. The
front windows and surrounds are not considered to be fully secure guards against accidental contact. It is
recommended that an approved fire screen be used if children, the elderly or persons with limited mobility are
to be present in the same area.
Do not place curtains, laundry, furniture etc. within a safe distance of 300mm of this appliance.
Do not attempt to burn rubbish on this appliance.
If this appliance is extinguished, on purpose or other, no attempt to relight should be made within 3 minutes.
Flue Systems
Mendip products are approved for use with the following Flue Systems (inc. types C11, C31 and C91):
Metaloterm US.
Muelink & Grol (M&G) Concentric.
Poujoulat PGI.
Jeremias TWG (System TWIN-GAS).
Flexinox (Thermo Products BV) Thermovent Con.

GB & IE
5
2. User instructions.
2.1 Emergency Gas Isolation
In the event of a gas leak or if gas is smelt, the appliance must be isolated. This is done by turning OFF the gas
at the Isolation Tap. This Isolation Tap is located in the foot of the appliance.
2.2 First Time of Operation
Before igniting the appliance, ensure that all packaging, safety stickers and any protective wrapping have been
removed, and that the glass has been cleaned, including all fingerprints from the glass.
Ensure that the room is adequately ventilated the first time that the appliance is ignited; we would recommend
opening windows if possible. Run the appliance at full setting for a few hours so that the paint gets an
opportunity to fully cure. During this period it is possible for some fumes and vapours to be given off. We would
recommend keeping children and pets out of the area at this time.

GB & IE
6
2.3 Control Overview
2.3.1 Basic Manual Control
1. Igniting the Pilot Light
1. From the OFF position, depress the control knob for five seconds (only pilot gas flows).
2. Turn the control knob anti-clockwise through the PILOT position and continue turning until the igniter
“clicks”, if the Pilot flame lights, hold for ten seconds (only pilot gas flows). If the Pilot has not Ignited,
return the control knob to the OFF position and repeat.
3. Upon releasing the control knob the pilot flame should remain alight, if not return the control knob to the
OFF position and repeat.
2. Igniting the Main Burner
The appliance should always be run on FULL for the first 30 seconds.
From the IGNITION position, turn the control knob fully anti-clockwise, this is the FULL position, gas should now be
flowing to the main burner and the burner should light on full.
3. Adjusting the Flame Height (heat setting)
From the FULL position, turn the control clock-wise, until the control knob reaches a stop, this is the LOW setting.
Any position between HIGH and LOW can be selected as an intermediate setting.

GB & IE
7
4. Leaving the appliance in Pilot Position
In the Pilot Position, only the Pilot flame will remain alight.
Depress and turn the control clockwise, through the LOW setting to the PILOT setting.
The appliance can be left in this position, however we would recommend turning the appliance OFF if not required
within a few hours.
5. Turning the appliance OFF
From any heat setting or PILOT, Depress and turn the Control knob fully clockwise to reach the OFF position, and
release the control knob. The appliance will now be OFF.

GB & IE
8
2.3.2 Remote Control

GB & IE
9

GB & IE
10
Altri manuali per Ashcott
2
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Mendip Stoves Stufa

Mendip Stoves
Mendip Stoves 5 standard Manuale utente

Mendip Stoves
Mendip Stoves WOODLAND DS Scheda tecnica

Mendip Stoves
Mendip Stoves Christon 400 Series Scheda tecnica

Mendip Stoves
Mendip Stoves Churchill 5 SE MK4 Dual Control Scheda tecnica

Mendip Stoves
Mendip Stoves 8 standard Manuale utente

Mendip Stoves
Mendip Stoves Christon 400 Series Scheda tecnica

Mendip Stoves
Mendip Stoves Loxton 5 SE Scheda tecnica

Mendip Stoves
Mendip Stoves Loxton 3 Scheda tecnica

Mendip Stoves
Mendip Stoves Loxton 5 Scheda tecnica

Mendip Stoves
Mendip Stoves Ashcott Guida