mensor CPG2500 Manuale utente

Operating Instructions
Precision Pressure Indicator
Precision Pressure Indicator CPG2500 PN 0018908001F • 02/2017
CPG2500

2 Operating Instructions - CPG2500
Precision Pressure Indicator
CPG2500
Warning
!
This Warning symbol indicates that danger of injury for
persons and the environment and/or considerable damage
(mortal danger, danger of injury) will occur if the respective
safety precautions are not taken.
!
Caution
This Caution symbol indicates danger for the system and
material if the respective safety precautions are not taken.
i
Notice
This Notice symbol does not indicate safety notices but
information for a better understanding of the facts.

Operating Instructions - CPG2500 3
Precision Pressure Indicator
CPG2500
1. General Information 7
1.1 Warranty 7
1.2 Important Notice 7
1.3 FCC Radio Frequency Emission Notice 7
1.4 Trademarks and Copyrights 8
1.5 Software License Agreement 8
1.6 Mensor Service Plus 8
1.6.1 After the Warranty 8
1.6.2 Calibration Services 8
1.6.3 Certications and Accreditations 8
1.7 Packaging for Shipment 8
2. Safety Notices 9
2.1 User Responsibilities 9
2.2 General Safety Notices 9
2.3 Warnings and Caution Notices 10
3. General Description 11
3.1 Features 11
3.2 Turning On 12
3.3 Front Panel 12
3.4 Display 13
3.5 Chassis Assembly 13
4. Specications 15
4.1 Transducer Specication 15
5. Installation 18
5.1 Unpacking the Instrument 18
5.2 Dimensions (inches) 19
5.3 Mounting 20
5.4 Rear Panel 20
5.4.1 Pressure Connections 21
5.4.2 Pressure Port 21
5.4.3 Reference Port 21
5.5 Remote Communication Connections 21
5.6 Power Up 21
6. Local Operation and Setup 22
6.1 General Operation 22
6.1.1 Setup Applications 22
6.1.2 Display Screen Features 22
Table of Contents

4 Operating Instructions - CPG2500
Precision Pressure Indicator
CPG2500
6.2 Initial Setup 23
6.2.1 Contact and Version Information Application 23
6.2.2 Language Selection 23
6.3 Application Selection and parameter inputs 24
6.4 Applications: 25
6.4.1 Measure Application 25
6.4.1.1 Pressure Mode / Emulation Mode 26
6.4.1.2 Auxiliary Displays 26
6.4.1.3 Zero Button 27
6.4.1.4 Tare Button 28
6.4.2 Settings Application 29
6.4.2.1 Languages 29
6.4.2.2 Brightness 30
6.4.2.3 Volume 30
6.4.2.4 User base units / Base units multiplier 31
6.4.2.5 Barometer Units 31
6.4.2.6 Conguration 32
6.4.3 Frames Application 33
6.4.3.1 Frame Format 33
6.4.3.2 Frames Channel 34
6.4.4 Transducer Application 35
6.4.4.1 Transducer Channel Selection 35
6.4.4.2 Transducer Delta Emulation 36
6.4.4.3 Transducer Filter 36
6.4.4.4 Transducer resolution 37
6.4.4.5 Auxiliary Displays 38
6.4.4.6 Cal Function 39
6.4.5 Remote Application 40
6.4.5.1 Remote Command Set 40
6.4.5.2 Remote Communication Settings 41
6.4.6 Info Application 42
6.4.7 Leak Test Application 43
6.4.8 Troubleshooting Application 44
6.4.9 Service Application 45
6.4.10 Unlocked Service Application 46
7. Remote Operation 48
7.1 Command Set 48
7.2 IEEE-488 48

Operating Instructions - CPG2500 5
Precision Pressure Indicator
CPG2500
7.2.1 IEEE-488.2 Commands 48
7.3 Ethernet 49
7.4 Serial 50
7.4.1 Serial Cable Requirements 50
7.5 Mensor Command Set 51
7.6 Command and Query Format 51
7.7 Command Set Denitions 51
7.8 Output Formats 52
7.9 CPG2500 Commands and Queries 52
7.9.1 Units Command Syntax for Measurement Units 57
7.9.2 CPG2500 Error Codes 58
7.9.3 SCPI Commands and Queries 58
7.9.4 SCPI Commands Error Messages and Error Codes 60
7.9.5 GPIB Capability Codes 60
7.9.6 Interface Functions 60
8. Options 62
8.1 Barometer 62
8.2 Barometric Reference 62
8.2.1 Absolute Pressure Emulation 62
8.2.2 Emulation Mode Accuracy 63
8.2.3 Barometric Reference Calibration 63
8.2.4 Barometric reference Specications 63
8.3 Delta Channel 63
8.4 External Transducers (CPT6100 and CPT6180) 63
8.4.1 External Pressure Sensor Connection Cable 63
8.5 External Sensor Package (D-Sub) 63
8.6 Analog Output 64
8.6.1 Specications 64
8.7 Rack Mount Kit 64
8.8 Fittings 64
8.9 Remote Calibration 64
8.9.1 Remote Calibration Kit for Internal Transducers. 65
8.9.2 Barometric Reference Calibration Sled 65
8.9.3 External Calibration Procedures 66
8.9.3.1 Transducer Removal 66
8.9.3.2 Barometric Reference Removal 66
9. Maintenance 68
9.1 Beyond the Warranty 68

6 Operating Instructions - CPG2500
Precision Pressure Indicator
CPG2500
9.2 Spare Parts 68
10. Calibration 70
10.1 Environment 70
10.2 Pressure Standards 70
10.3 Media 70
10.4 Setup 71
10.5 Service Application 72
10.5.1 Service Application (unlocked) 73
10.6 Calibration Data 74
10.7 One Point Cal Application 74
10.8 Two Point Cal Application 75
10.9 Linearization 76
10.10 Head Pressure 78
11. Appendix 80
11.1 Conversion Factors, PSI 81
11.2 Conversion Factors, Millitorr 82
11.3 Conversion Factors, Pascal 83

Operating Instructions - CPG2500 7
Precision Pressure Indicator
CPG2500
1 General Information
1.1 Warranty
All products manufactured by Mensor are warranted to be free of defects in workmanship and materials for
a period of two years from the date of shipment. No other express warranty is given, and no armation of
Seller, by words or actions, shall constitute a warranty. SELLER DISCLAIMS ANY IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSES WHATSOEVER. If any defect
in workmanship or material should develop under conditions of normal use and service within the warranty
period, repairs will be made at no charge to the original purchaser, upon delivery of the product(s) to the
factory, shipping charges prepaid. If inspection by Mensor or its authorized representative reveals that the
product was damaged by accident, alteration, misuse, abuse, faulty installation or other causes beyond the
control of Mensor, this warranty does not apply. The judgment of Mensor will be nal as to all matters con-
cerning condition of the product, the cause and nature of a defect, and the necessity or manner of repair.
Service, repairs or disassembly of the product in any manner, performed without specic factory permis-
sion, voids this warranty.
MENSOR MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MANUAL, INCLUDING,
BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. Mensor shall not be liable for errors contained herein or for incidental or con-
sequential damages in connection with the furnishing, performance, or use of this material.
1.2 Important Notice
The product specications and other information contained in this manual are subject to change without
notice.
Mensor has made a concerted eort to provide complete and current information for the proper use of
the equipment. If there are questions regarding this manual or the proper use of the equipment, contact
Mensor at:
Mensor WIKA Alexander Wiegand SE & Co. KG
201 Barnes Drive Alexander-Wiegand-Straße 30
San Marcos, Tx 78666 D-63911 Klingenberg / Germany
Tel: 1.512.396.4200 Tel: (+49) 93 72/132-9986
1.800.984.4200 (USA only) web site: www.wika.de
web site: www.mensor.com fax: (+49) 93 72/132-8767
e-mail: sales@mensor.com
tech.support@mensor.com
1.3 FCC Radio Frequency Emission Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the in-
struction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to cor-
rect the interference at his or her own expense.
USE SHIELDED CABLES TO CONNECT EXTERNAL DEVICES TO THIS INSTRUMENT TO MINIMIZE
RF RADIATION.

8 Operating Instructions - CPG2500
Precision Pressure Indicator
CPG2500
1.4 Trademarks and Copyrights
Mensor is a registered trademark of Mensor, LP. All other brand and product names are trademarks or
registered trademarks of their respective companies. ©2007, Mensor, LP. All rights reserved.
1.5 Software License Agreement
This product contains intellectual property, i.e., software programs, that are licensed for use by the end
user/customer (hereinafter “end user”).
This is not a sale of such intellectual property.
The end user shall not copy, disassemble or reverse compile the software program.
i
Notice
The software programs are provided to the end user “as is” without warranty
of any kind, either express or implied, including, but not limited to, warranties
ofmerchantabilityandtnessforaparticularpurpose.Theentireriskofthe
quality and performance of the software program is with the end user.
Mensor and its suppliers shall not be held to any liability for any damages suered or incurred by the end
user (including, but not limited to, general, special, consequential or incidental damages including dam-
ages for loss of business prots, business interruption, loss of business information and the like), arising
from or in connection with the delivery, use or performance of the software program.
1.6 Mensor Service Plus
If you have problems and you don’t nd the answer in this manual, contact Mensor at 1.800.984.4200
(USA only) or 1.512.396.4200 for personal assistance, or at any of the contact addresses listed on the
rear cover of this manual. We are ready to help.
1.6.1 After the Warranty
Mensor’s concern with the performance of this instrument is not limited to the warranty period. We pro-
vide complete repair, calibration and certication services after the warranty for a nominal fee.
1.6.2 Calibration Services
In addition to servicing our own products Mensor can perform a complete pressure calibration service,
up to 20,000 psi, for all of your pressure instruments. This service includes an accredited calibration.
1.6.3 CerticationsandAccreditations
Mensor is registered to ISO 9001:2008.The calibration program at Mensor is accredited by A2LA, as
complying with both the ISO/IEC 17025:2005 and the ANSI/NCSL Z540-1-1994 standards.
1.7 Packaging for Shipment
If the product must be shipped to a dierent location or returned to Mensor for any reason through a com-
mon carrier it must be packaged properly to minimize the risk of damage.
The recommended method of packing is to place the instrument in a container, surrounded on all sides
with at least four inches of shock attenuation material such as styrofoam peanuts.

Operating Instructions - CPG2500 9
Precision Pressure Indicator
CPG2500
2 Safety Notices
2.1 User Responsibilities
To ensure safety, the user must make sure that:
• The system is used properly, no dangerous media are used and that all technical specications are
observed.
• The system is operated in perfect operating condition.
• This operation manual is legible and accessible to the user at the system’s location.
• The system is operated, serviced and repaired only by authorized and qualied personnel.
• The operator receives instruction on industrial safety and environmental protection, and is knowledge-
able of the operating instructions and the safety notices contained therein.
2.2 General Safety Notices
i
Notice
The system should only be operated by trained personnel who are familiar with
this manual and the operation of the instrument.
Warning
!
WARNING: A condition for trouble-free and safe operation of this system is proper
transport, proper storage, installation, assembly and proper use as well as careful
operation and maintenance.
Any operation not described in the following instructions should be prohibited.
The system must be handled with care required for an electronic precision instru-
ment(protectfromhumidity,impacts,strongmagneticelds,staticelectricityand
extreme temperatures). Do not insert any objects into the instrument.
The system is powered via the power cable with a voltage that can cause physi-
cal injury. Even after disconnecting the system from the power supply, dangerous
voltages can temporarily occur due to capacitance.
Extreme care must be taken with pressure connections when using hazardous or
toxic media.
Repairs must only be performed by authorized service personnel.
i
Notice
Additional safety notices are found throughout this manual.

10 Operating Instructions - CPG2500
Precision Pressure Indicator
CPG2500
2.3 Warnings and Caution Notices
Warning
!
WARNING: HIGH PRESSURE! High pressure gases are potentially hazardous.
Energy stored in these gases and liquids can be released suddenly and with
extreme force. High pressure systems should be assembled and operated only by
personnel who have been trained in proper safety practices.
Warning
!WARNING: NOT EXPLOSION PROOF! Installation of this instrument in an area
requiring devices rated as intrinsically safe is not recommended.
Warning
!
WARNING: POSSIBLE INJURY! The tubing, valves, and other apparatus attached
to the gauge must be adequate for the maximum pressure which will be applied,
otherwise physical injury to the operator or bystanders is possible.
!
Caution
CAUTION: USE THE PROPER PRESSURE MEDIUM! Use only clean, dry, non-corro-
sivegasesunlessotherwisespeciedbyMensor.Thisinstrumentisnotdesigned
for oxygen use.
!
Caution
CAUTION: As with most sensitive electronic equipment, switch the power switch
obeforeconnectingordisconnectingtoapowersourcetopreventdataloss.Do
notpositiontheequipmentsothatitisdiculttodisconnecttheDCpowerjack.
CAUTION: ESD PROTECTION REQUIRED. The proper use of grounded work
surfaces and personal wrist straps are required when coming into contact with
exposed circuits (printed circuit boards) to prevent static discharge to sensitive
electronic components.
Additional Warning and Caution notices are found throughout this manual.
Indice
Manuali Stazione meteorologica popolari di altre marche

National Geographic
National Geographic VA Colour RC Manuale utente

Renkforce
Renkforce 1208067 Manuale utente

Levenhuk
Levenhuk Discovery Report WA40 Manuale utente

Instant Transmission
Instant Transmission MA 10410 Manuale utente

Lutron Electronics
Lutron Electronics PHB-318 Manuale utente

WAREMA
WAREMA EWFS Weather station eco Manuale utente