Service Menu
To access the service menu, press and hold the Adjust Control/Select Button for 5 seconds, then
release. Rotate the knob to scroll through the menu items. Press and release the control to access
the options and information within each menu item.
Rotate the control to scroll or change value. Press and release control to save selection. After 5
seconds of inactivity, the menu will time out and the selection will be saved.
Codes Shown on EnPak Remote Control Panel Display
You could see a code show up on the EnPak screen to let you know there is some type of issue.
Check the manual for error code reference to help repair the issue. Resetting of Charge/Weld codes
can be done by either: changing position of the charge/weld switch; change positions of the process
select switch; cycle unit power off/on. Resetting of Air Compressor codes can be done by switching
the compressor Off, then On.
Getting Started (continued)
Menu Item
Selectable Item
Option(s) Description
HOUR MTR – – Displays the current Engine Hours.
ENG OIL
OIL HOUR Displays the current oil change countdown.
OIL SET Sets the oil change interval.
OIL RSET Resets the oil change countdown.
COMP OIL
OIL HOUR Displays the current oil change countdown.
OIL SET Sets the oil change interval.
OIL RSET Resets the oil change countdown.
RPM DISP – – Displays current engine RPM.
RPM SET
AUTO Enables auto speed function.
3600 Locks engine speed at 3600 RPM.
STOP TIME 2 to 30 min Unit idle time before auto stop (adjustable in 1 min increments).
MIN PRES 90 psi up to 10 psi less
than max pressure
Minimum pressure to start air compressor (adjustable in 1 psi
increments).
MAX PRES 175 psi down to 10 psi
greater than min pressure
Maximum pressure to stop air compressor (adjustable in 1 psi
increments).
SOFT WARE – – Displays the current revision of rmware installed.
FACT RSET
RSET YES Resets all settings to factory defaults.
RSET NO All settings remain at previous settings.