Millipore TANKASMIN Manuale utente

User Manual Automatic Sanitization Module
Model: TANKASMIN

Legal Information
Notice The information in this document is subject to change without notice and
should not be construed as a commitment by Millipore Corporation.
Millipore Corporation assumes no responsibility for any errors that might
appear in this document. This manual is believed to be complete and accurate
at the time of publication. In no event shall Millipore Corporation be liable
for incidental or consequential damages in connection with or arising from
the use of this manual.
We manufacture and sell water purification systems designed to produce pure
or ultrapure water with specific characteristics (μS/cm, T, TOC, CFU/ml,
Eu/ml) when it leaves the water purification system provided that the System
is fed with water quality within specifications, and properly maintained as
required by the supplier.
We do not warrant these systems for any specific applications. It is up to the
end user to determine if the quality of the water produced by our systems
matches his expectations, fits with norms/legal requirements and to bear
responsibility resulting from the usage of the water.
Warranty Millipore Corporation (“Millipore”) warrants its products will meet their
applicable published specifications when used in accordance with their
applicable instructions for a period of one year from shipment of the products.
MILLIPORE MAKES NO OTHER WARRANTY, EXPRESSED OR
IMPLIED. THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. The warranty provided herein
and the data, specifications and descriptions of Millipore products appearing
in Millipore’s published catalogues and product Literature may not be altered
except by express written agreement signed by an officer of Millipore.
Representations, oral or written, which are inconsistent with this warranty or
such publications are not authorized and if given, should not be relied upon.
In the event of a breach of the foregoing warranty, Millipore’s sole obligation
shall be to repair or replace, at its option, the applicable product or part
thereof, provided the customer notifies Millipore promptly of any such
breach. If after exercising reasonable efforts, Millipore is unable to repair or
replace the product or part, then Millipore shall refund to the customer all
monies paid for such applicable product or part. MILLIPORE SHALL NOT
BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR ANY
OTHER INDIRECT DAMAGES RESULTING FROM ECONOMIC LOSS
OR PROPERTY DAMAGE SUSTAINED BY ANY CUSTOMER FROM
THE USE OF ITS PRODUCTS.
Continued on next page

Legal Information continued
Trademarks The M mark, Millipore and Elix are registered trademark of Millipore
Corporation.
All other trademarks are trademarks of their respective manufacturers.
Copyright ©2007 MILLIPORE CORPORATION. PRINTED IN FRANCE. ALL
RIGHTS RESERVED. THIS BOOK OR PARTS THEREOF MAY NOT BE
REPRODUCED IN ANY FORM WITHOUT THE WRITTEN
PERMISSION OF THE PUBLISHERS
About Millipore
Telephone See the business card(s) on the inside cover of the User Manual binder.
Internet Site
Address
www.millipore.com/bioscience
Manufacturing
Site
Millipore SAS
67120 Molsheim
FRANCE
Document Rev. 0, 05/2008

Safety Information
Statement The ASM and other equipment must be operated according to the instructions
in this manual. In particular, the hydraulic and electrical specifications must
be followed and met. It is important to use this equipment as specified in this
manual; using this equipment in a different manner may impair the safety
precautions of the water system.
Symbols
Symbol Meaning
The light from an UV Lamp is very damaging to your
eyes and to your skin. Do not remove the ASM UV
Lamp at any time unless its power cable is totally
removed from the adjacent Water System.
The UV Lamp contains metallic Mercury. Please
dispose of any used UV Lamp in a manner that is
environmentally safe.
Danger: UV radiation! This sticker is used to refer to a
position on the Water System Cabinet or inside.
Danger! This sticker is used to refer to a position on the
Water System cabinet or inside.
Ground connection! This sticker is used to refer to a
position on the Water System Cabinet or inside.
Electrical danger! This sticker is used to refer to a
position on the Water System Cabinet or inside.
!

Table of Contents
Product information ...........................................................................................................1
Function............................................................................................................................1
Purpose.............................................................................................................................1
Components......................................................................................................................1
Weight and dimensions ....................................................................................................2
Electrical specifications....................................................................................................2
Environmental specifications ...........................................................................................2
ASM installation..................................................................................................................3
UV lamp ...........................................................................................................................3
ASM on a reservoir ..........................................................................................................4
Electrical connection........................................................................................................4
Software activation...........................................................................................................5
Registering ASM UV lamp ..............................................................................................5
ASM programming.............................................................................................................6
Manager Menu access ......................................................................................................6
ASM Lamp Schedule .......................................................................................................6
Example............................................................................................................................7
ASM UV lifetime.............................................................................................................7
Maintenance ........................................................................................................................8
Alert messages..................................................................................................................8
UV lamp replacement.......................................................................................................8
Quartz sleeve cleaning .....................................................................................................9
Ordering information .......................................................................................................10
Catalogue numbers.........................................................................................................10

1
Product information
Function The Automatic Sanitization Module (ASM) is designed to be fitted on
Millipore water storage reservoirs such as the 30 L, 60 L or 100 L PE
Reservoirs or the SDS 200/350.
The ASM is electrically powered and controlled by an adjacent water
system. The ASM illumination cycles are programmed via the water
system keypad and software.
Purpose The ASM makes use of the germicidal properties of ultra-violet (UV) light
at 254 nm.
The ASM prevents the formation of biofilm inside the Reservoir.
Components The table describes the main components of an ASM.
Part Function
Connector A plastic part that connects the ASM directly on the
water system.
Ballast An electrical board that powers the UV lamp.
Quartz sleeve A glass tube that protects the UV lamp.
UV lamp A lamp that emits UV rays.
Reservoir lid
and o-ring
A plug that can be screwed on all Millipore reservoir
opening.
Ballast
Reservoir lid
UV lamp
Connector
Quartz sleeve
Continued on next page

2
Product information, Continued
Weight and
dimensions ASM weight
The ASM weighs 1 kg.
ASM dimensions
Specification Value
Height 320 mm
Width 170 mm
Power cable
The maximum length of the power cable is 5 m.
Electrical
specifications
The table shows the value of each specification.
Specification Value
Consumption 12 VA
Supply Voltage to ASM 24 VDC
Environmental
specifications
The ASM is intended for indoor use only, under the conditions stated
below.
Specification Range or value
Ambient storage temperature between 5 - 40°C
Altitude below 3000 m
Installation category II
Pollution degree 2

THE INFORMATION IN THIS PAGE IS MEANT TO BE USED
BY A QUALIFIED MILLIPORE SERVICE REPRESENTATIVE
3
ASM installation
UV lamp Before proceeding, make sure the ASM is not electrically
connected to the Water System.
The following procedure shows the installation of the UV lamp.
Step Action
1 Separate the ballast from the reservoir lid by removing the two
screws.
2 Connect the Ballast wires to the UV lamp by pushing the
connector onto the 4 pins of the UV Lamp.
3 Insert the UV lamp into the quartz sleeve.
Attention! Handle the UV lamp carefully. Use gloves.
4 Secure the ballast to the reservoir lid with the two screws.
Continued on next page
!

THE INFORMATION IN THIS PAGE IS MEANT TO BE USED
BY A QUALIFIED MILLIPORE SERVICE REPRESENTATIVE
4
ASM installation, Continued
ASM on a
reservoir
Put the ASM onto the top of the Reservoir by following the steps below.
Step Action
1 Remove the lid coming with the storage reservoir. This lid will
no longer be used.
2 Take the ASM and verify that the o-ring is well positioned,
inside the lid.
3 Screw the ASM with its lid onto the reservoir until it is hand
tight. Since there is an o-ring inside the lid, there is no need to
overtighten it.
Electrical
connection
Make sure the Water System is not powered when connecting the
ASM electrical cable. In addition, make sure the ASM UV Lamp
is inside the Reservoir.
•The ASM is connected on the side of the water system.
•Push the connector into the socket located on the left side of the system.
Continued on next page
!

THE INFORMATION IN THIS PAGE IS MEANT TO BE USED
BY A QUALIFIED MILLIPORE SERVICE REPRESENTATIVE
5
ASM installation, Continued
Software
activation
The ASM must be activated into the water system software.
•In the Service Menu, go in CONFIG and ASM Activation.
•Choose “Yes” and press .
Registering
ASM UV lamp
•The ASM UV lamp timer has to be registered.
•In Standby Menu, go in Maintenance. And follow the screen
instructions.
Indice