3. Connect the Ethernet cable from Ethernet Port 3 on the SmartLink to the Ethernet
Port on the TrafficLink Interface ABC.
4. Connect the SmartLink to the power supply (terminal block wiring or 110V-240V
non-GFCI) and then turn on the SmartLink.
5. Verify that the Power LED is solid green.
6. Verify that the NET LED is solid green. The SmartLink might take a few minutes
to connect to TrafficLink. You can continue installing other components while the
SmartLink is connecting.
Install the TrafficLink Interface ABC
If you prefer to review these steps in a video tutorial, see ABC(D) interface installation.
If you need help attaching the ABCD cables, use the supplied MioChuck to grasp the
cables. (Your installation might not require a D cable.)
1. If you are installing the TrafficLink Interface vertically, as recommended for
optimal ventilation, screw the cabinet clip to the back of the TrafficLink Interface.
Hand tighten the screws.
2. Place the TrafficLink Interface ABC(D) in the planned location in the cabinet.
3. Attach the ABC(D) cables to the corresponding color-coded inputs on the
CONTROLLER side of the TrafficLink Interface.
4. When it is safe to do so, manually put the intersection into flash mode.
5. Disconnect the ABC(D) cables from the existing controller.
6. Attach the ABC(D) cables from the cabinet to the corresponding color-coded
inputs on the CABINET side of the TrafficLink Interface.
7. Attach the ABC(D) cables from the CONTROLLER side of the TrafficLink Interface
to the corresponding inputs on the controller.
8. Connect the TrafficLink Interface to the power supply (terminal block wiring or
110V-240V non-GFCI) and then turn on the TrafficLink Interface.
9. Verify that the TrafficLink Interface power LED is solid green. If it is not, check the
cable connections.
10. Return the intersection to its normal operating mode.
6.11.19