Mircom OpenBAS-NWK-ETH3 Manuale utente

Installation Manual
Ethernet Controller
LT-2204 Rev. 0
June 2017
OpenBAS-NWK-ETH3


3 (30)
Table of Contents
1.0 Introduction 6
1.1 OpenBAS-NWK-ETH3 Ethernet Controller .................................................................... 6
1.2 Features ......................................................................................................................... 6
2.0 Overview 7
2.1 Controllers ...................................................................................................................... 7
2.2 OpenBAS-NWK-ETH3 Accessories ............................................................................... 7
2.3 Compatible modules ...................................................................................................... 8
3.0 Installation 9
3.1 Parts of the Enclosure .................................................................................................... 9
3.2 Controller Board Connections ........................................................................................ 12
3.3 Installing Accessories .................................................................................................... 12
3.3.1 Communication Converters (OpenBAS-ACC-RS485, OpenBAS-ACC-RS232) ............ 12
3.3.2 Memory Expansion Card (OBS-ACC-32K128) and Wireless Receiver
(OpenBAS-HV-RF433R) ................................................................................................ 14
3.4 USB1: Connection for Programming .............................................................................. 14
3.5 USB2: Connection for Backup ....................................................................................... 14
3.6 Reset and Download Buttons ........................................................................................ 14
3.7 Battery ............................................................................................................................ 15
3.8 Enclosure Dimensions ................................................................................................... 16
3.9 Assembly ....................................................................................................................... 17
3.10 Mounting the Enclosure ................................................................................................. 18
4.0 Field Wiring and LEDs 19
4.1 Wiring Requirements ..................................................................................................... 19
4.1.1 Required Tools ............................................................................................................... 19
4.1.2 Installation Tips .............................................................................................................. 19
4.2 Power Supply Connection .............................................................................................. 19
4.2.1 Powering Devices in Parallel ......................................................................................... 20
4.3 Ethernet Port .................................................................................................................. 20
4.4 Field Bus Connections and OpenBAS-ACC-DB9 (OpenBAS-NWK-ETH3 only) ........... 20
4.4.1 OpenBAS-ACC-DB9 ...................................................................................................... 20
4.5 Connecting OpenBAS-NWK-ETH3 or OpenBAS-NWK-ETHXP to an
OpenBAS-HV-NX10 Series Controller ........................................................................... 21
4.5.1 SPI Port .......................................................................................................................... 21
4.5.2 RS-485 (OpenBAS-NWK-ETH3 only) ............................................................................ 21
4.6 LEDs .............................................................................................................................. 22
5.0 Specifications 23
6.0 Master Warranty and Warning Information 24
7.0 Special Notices 29

4 (30)
List of Figures
Figure 1 Parts of the enclosure .................................................................................................... 9
Figure 2 Tabs on enclosure .......................................................................................................... 10
Figure 3 Lift tabs and remove circuit board .................................................................................. 11
Figure 4 Controller board connections and buttons ..................................................................... 12
Figure 5 Communication converter connection and field bus ports ............................................. 13
Figure 6 The jumper and RS-485 module are removed ............................................................... 13
Figure 7 OpenBAS-ACC-RS232 is installed ................................................................................ 14
Figure 8 Enclosure (back view) .................................................................................................... 16
Figure 9 Fit the circuit board in the enclosure .............................................................................. 17
Figure 10 Enclosure mounted on DIN rail (circuit board not shown) .............................................. 18
Figure 11 Enclosure mounted on DIN rail (back view) ................................................................... 18
Figure 12 Powering Devices in Parallel .......................................................................................... 20
Figure 13 Networking with SPI ....................................................................................................... 21
Figure 14 Networking with RS-485 ................................................................................................. 21
Figure 15 Details of RS-485 Networking ........................................................................................ 22
Figure 16 LEDs .............................................................................................................................. 22

5 (30)
List of Tables
Table 1 Controllers ...................................................................................................................... 7
Table 2 OpenBAS-NWK-ETH3 Accessories ............................................................................... 7
Table 3 Compatible Modules ...................................................................................................... 8

6 (30)
1.0 Introduction
This document provides information on installing the OpenBAS-NWK-ETH3 Ethernet
controller.
1.1 OpenBAS-NWK-ETH3 Ethernet Controller
Mircom’s OpenBAS-NWK-ETH3 is an Ethernet gateway and controller that can connect to a
single OpenBAS-HV-NX10 series controller to provide Web server and IP protocol capability. It
has 2 field bus connections that are factory set to RS-485. One can be changed to RS-232
with accessories. It has a real time clock and calendar, programming logic controller and
scheduler to operate as a building controller.
1.2 Features
The OpenBAS-NWK-ETH3 Ethernet controller integrates into Mircom’s unified platform for
automating HVAC and mechanical rooms as well as incorporating energy management
features and lighting control to offer building owners and managers a seamless operation with
the following features:
•Modular design to cover any small, medium or large project.
•Industry standard field bus protocols to integrate into any existing BAS system such as
BACnet, Modbus, N2-Open, and ASCII.
•Advanced Networking to integrate into IP networks and use the most advanced features
and protocols such as distributed computing, USB and Cloud storage, HTML5,
JavaScript, XML, Ajax, SMS, and GSM.
•Universal inputs to connect any industry standard sensors.
•Modular add-ons for every Building Automation System solution.
•The OpenBAS software which provides owners and managers a single solution for
managing all their building’s automation needs.
Caution: Consult this document to learn about potential hazards. Hazards are
marked on the controller with the symbol on the left.

7 (30)
2.0 Overview
2.1 Controllers
2.2 OpenBAS-NWK-ETH3 Accessories
Accessories are powered from the controller.
Table 1 Controllers
Picture Model Description
OpenBAS-NWK-ETH3
Ethernet gateway and controller with
support for multiple protocols
• 2 field bus connections
• I2C port for memory expansion
and connection to wireless
receiver
• SPI port for connection to an
OpenBAS-HV-NX10 series
controller
• Mounts in a DIN rail-mounted box
OpenBAS-NWK-ETHXP
• Ethernet gateway with support for
multiple protocols
• SPI port for connection to an
OpenBAS-HV-NX10 series
controller
• Mounts in a DIN rail-mounted box
Minimum order: 100 units
Table 2 OpenBAS-NWK-ETH3 Accessories
Model Description
OpenBAS-ACC-RS485 Optically isolated RS-485 converter
OpenBAS-ACC-RS232 RS-232 converter
OpenBAS-ACC-DB9 DB9 adapter
OBS-ACC-32K128 128KB EEPROM plus 32 KB non-volatile
RAM memory expansion

8 (30)
Overview
2.3 Compatible modules
Compatible modules are mounted separately from the controller.
Table 3 Compatible Modules
Model Description
OpenBAS-HV-LEARN
Learning module for OpenBAS-HV-NX10 series controllers
Includes hardware to simulate inputs and outputs, 2 field bus
ports, SPI and I²C buses
Powered with a USB connector
OpenBAS-HV-NX10P
HVAC controller
• Integrated programmable logic controller and scheduler
• 18 hardware input/output points
• 2 RS-485 field bus connections
• USB, SPI and I²C buses
OpenBAS-HV-NX10L
HVAC controller plus the OpenBAS-HV-LCD display
• Integrated programmable logic controller and scheduler
• 18 hardware input/output points
• 2 RS-485 field bus connections
• USB, SPI and I²C buses
• Operator interface with LCD and keyboard
OpenBAS-HV-NX10D
HVAC controller plus the OpenBAS-HV-CORE2 display
• 32 bit dual core processor
• Scheduler and 3 integrated programmable logic controllers
• 18 hardware input/output points
• 3 RS-485 field bus connections,
• USB, SPI and I²C buses
• Operator interface with graphical LCD, keyboard, and
secondary USB for data storage
OpenBAS-HV-RF433R (OpenBAS-NWK-
ETH3 only)
Wireless 433 MHz RF receiver that integrates up to 16 wireless
transmitters and thermostats into OpenBAS-NWK-ETH3
controllers
Mounts in a DIN rail-mounted box

9 (30)
3.0 Installation
3.1 Parts of the Enclosure
Figure 1 Parts of the enclosure
Attention: Installation of OpenBAS devices should be in accordance with the
Canadian Electrical Code or the National Electrical Code, and comply
with all local regulations. Final acceptance subject to the Local
Authority Having Jurisdiction (AHJ).
If this equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
The safety of any system incorporating this equipment is the
responsibility of the assembler of the system.
Note: In case of malfunction or damage, do not make any attempts at repair.
Do not dismantle this product.
This product does not require cleaning and should not be cleaned.
!
i
Circuit board
Base with
mounting clip
Enclosure
Cover

10 (30)
Installation
To remove the circuit board from the enclosure
1. Insert a flathead screwdriver under the tabs on the enclosure, shown in Figure 2, in order
to lift the tabs and remove the base.
Figure 2 Tabs on enclosure
2. Hold the circuit board with one hand, and with the other hand lift the tabs so that you can
remove the circuit board from the enclosure. See Figure 3.
Caution: Risk of Electric Shock. Disconnect the mains power and disconnect the
device from all wiring before opening the enclosure.
Attention: Always hold circuit boards by the edges to prevent damage from static
electricity. Always wear an anti-static bracelet when handling circuit
boards.
!
Indice
Altri manuali Mircom Controllori

Mircom
Mircom OpenBAS-HV-NX10 Series Manuale utente

Mircom
Mircom TX3-BBCX-4W Guida di riferimento

Mircom
Mircom TX3 Series Manuale utente

Mircom
Mircom RB-MD-1086 Series Manuale utente

Mircom
Mircom TX3-BBCX-4W Manuale utente

Mircom
Mircom OpenBAS-LC-NX12R Manuale utente

Mircom
Mircom RAM-2944LCD Manuale utente

Mircom
Mircom TX3 Series Manuale

Mircom
Mircom OpenBAS-HV-NX4AO Manuale utente

Mircom
Mircom TX3 Series Manuale utente