MITECH Garden/Tower-MICRO Series Specifiche tecniche

Garden/Tower-MICRO Rev. 2 - 03/2015 –
MITECH srl reserves the right to change the information in this document without warning.
English
Series
G
GG
G
G
GG
GA
AA
A
A
AA
AR
RR
R
R
RR
RD
DD
D
D
DD
DE
EE
E
E
EE
EN
NN
N
N
NN
N-
--
-
-
--
-T
TT
T
T
TT
TO
OO
O
O
OO
OW
WW
W
W
WW
WE
EE
E
E
EE
ER
RR
R
R
RR
R
M
MM
M
M
MM
MI
II
I
I
II
IC
CC
C
C
CC
CR
RR
R
R
RR
RO
OO
O
O
OO
O
Use and installation manual

Garden/Tower-Magnus Use and installation manual Page 2di 20
Index
Anti-intrusion column 3
Main com onents 4
Additional com onents 5
General installation instructions 6
Mounting o tions 6
Wall mounting 6
Ground mounting 7
Fixing the column to the base 8
Inserting the cover and closing the column 9
Mounting the lam 10
Exam les of installation 11
Exam le of how to rotect an inde endent building 12
Column su ly 13
Microwave Barrier Detection System 14
Introduction 14
Technical s ecifications and connections
15
Warnings and general characteristics 16
Notes 17-18-19

Garden/Tower-MICRO Use and installation manual Page 3of 20
Anti-intrusion column
View of the
column
without
protection cover
IMPORTANT
- Power the device using the
13.8 Vdc stabilised voltage only.
- In order for the column to work
correctly, ensure the power voltage
never falls below 12 Vdc.
- It is imperative you switch on the
temperature control system for both
internal and external installations
(power –supply 24Vac).

Garden/Tower-MICRO Use and installation manual Page 4of 20
Main com onents
2
3
1
4
Part
PartPart
Part
Quantity
QuantityQuantity
Quantity
Description
DescriptionDescription
Description
1 1 Aluminum profile
2 1 IR polycarbonate cover
3 1 Upper cover
1 Lower cover
5 1 Receiver or transmitter
microwave device
6 1 Tamper
5
6

Garden/Tower-MICRO Use and installation manual Page 5of 20
Additional com onents
1A
3
8
2
5
6
1B
4
7
Components included
Components includedComponents included
Components included
(TW = Tower – GAR = Garden)
Part
PartPart
Part
Quantity
QuantityQuantity
Quantity
Description
DescriptionDescription
Description
1A
(TW e GAR)
1
Ground fixing base
1B
(TW e GAR)
1
Wall fixing base
2
(TW e GAR)
1
Bracket
3
(TW e GAR)
Screws with
washers
(TW e GAR)
3
Clamps
5
(solo GAR)
1
Upper lamp cover
6
(solo GAR)
1
Lamp holder
Optional
OptionalOptional
Optional
Pa
PaPa
Pa
rt
rtrt
rt
Quantity
QuantityQuantity
Quantity
Description
DescriptionDescription
Description
7
(only GAR)
GAR
LAMP
CO/WH
Globe
(32 cm diameter, colour
cognac CO or white WH)
8
(TW e GAR)
GAR
POW
Dual power supply
unit
(normally supplied
separately, on request
it can be inserted inside
the column)
9
(only TW)
TW
CAP-PR
A
nti
-
removal
pressure cap
9

Garden/Tower-MICRO Use and installation manual Page 6of 20
General installation instructions
1. After installing the column, make sure that it is perfectly closed with the watertight
covers supplied.
2. Make sure that the path between the sensors is free and that there are no obstacles
that could affect the communication between the optical assemblies of the transmitters
and receivers that could interfere with the beams (i.e. branches, plants, leaves, snow,
etc).
3. Verify that the optical path of the transmitter used by the receiver column is not exposed
to direct sunlight at dawn and sunset.
4. If possible, do not use switching power supplies that cause disturbance to power
supplies when amplified by optically synchronized systems.
Mounting o tions
Columns may be mounted in two ways:
1. with a specific wall mounting base
2. with a specific ground mounting base.
Which in turn may be fixed in two ways:
•with clamps, fixing the base to a plinth
•with fixing gussets
Wall mounting
Wall mountingWall mounting
Wall mounting
Drill 4 holes of Ø 8 mm in the wall, level with the
base fixing holes.
Insert TE M8 steel gussets (not supplied) and fix
the base
200
210
Ø
33

Garden/Tower-MICRO Use and installation manual Page 7of 20
Ground mounting
Ground mountingGround mounting
Ground mounting
with clamps, fixing the base to a plinth
This fixing method is the most secure.
It requires a cement base in which to anchor
the clamps provided.
Ensure the plinth contains a tube (Ø 20 mm)
through which to thread the cables.
with fixing gussets
Drill 3 holes of Ø 8 mm in the ground, level
with the base fixing holes.
Insert TE M8 steel gussets (not supplied) and
fix the base.
210
200
210
Ø
33
200
Ø33
200

Garden/Tower-MICRO Use and installation manual Page 8of 20
Fixing the column to the base
Insert the lower cover into the base guide.
Insert the aluminium profile into the base
guide and into the relevant slot in the lower
cover.
Insert the connecting bracket between the
lower cover and the aluminium profile.
Screw 2 TE M6x20 screws through the
bracket and the base and 2 TE M6x25 screws
through the bracket and the profile.
M6x25
M6x20
squadretta

Garden/Tower-MICRO Use and installation manual Page 9of 20
Inserting the cover and closing the column
Insert the polycarbonate cover from above,
making it slide down as far as the column
base and inserting it into the lower cover.
Place the upper cover and screw it to the
column by means of 2 O-ring screws (supplied).

Garden/Tower-MICRO Use and installation manual Page 10 of 20
Mounting the lam
Place the specific upper cover that connects to the
lamp holder, ensuring the power cables are properly
threaded.
Screw the cover to the column by means of
2 O-ring screws (supplied).
Connect the wires to the lamp holder terminal.
Fix the lamp holder to the cover using the 2
Allen screws found at the sides
(5 mm spanner).
Insert the bulb.
Place the lamp shade on the supporting base
and turn it clockwise.
Fix it in place using the screw found on the
supporting base.
Viti a
brugola
vite
Indice
Manuali Luce esterna popolari di altre marche

Lindby
Lindby 9949029 Manuale utente

HEPER
HEPER DOGO Side LW6048.585-US Istruzioni per l'installazione e il funzionamento

HEPER
HEPER LW8034.003-US Istruzioni per l'installazione e il funzionamento

Maretti
Maretti VIBE S 14.6080.04.A Manuale utente

BEGA
BEGA 84 253 Manuale

HEPER
HEPER MINIMO Istruzioni per l'installazione e il funzionamento

LIGMAN
LIGMAN BAMBOO 3 Manuale utente

Maretti
Maretti TUBE CUBE WALL 14.4998.04 Manuale utente

Maxim Lighting
Maxim Lighting Carriage House VX 40428WGOB Manuale utente

urban ambiance
urban ambiance UQL1273 Manuale utente

TotalPond
TotalPond 52238 Manuale utente

Donner & Blitzen
Donner & Blitzen 0-02661479-2 Manuale utente





