Failure to properly follow these precautions
can result in property damage, serious injury or
DEATH !
Read all labels and the owner's manual before
operating this generator.
Generators produce carbon monoxide, a
poisonous, colorless, odorless gas that can cause
death or serious injury.
Indoor use of a generator CAN KILL QUICKLY.
Generators should be used outdoors only.
Generators should be used outdoors only and
away from garages and open windows and
protected from rain and snow.
Check for spilled fuel or leaks. Clean and/or repair
before use.
Always stop engine before refueling. Wait 5
minutes before restarting.
Keep any source of ignition away from fuel tank at
all times.
The portable generator is not meant to be used as
a permanent back-up power system for the home.
Indicates a strong possibility of severe personal
injury or death if instructions are not followed.
Indicates a possibility of personal injury or
equipment damage if instructions are not followed.
Provides helpful information.
1. Safety Instructions
This generator is designed to provide safe and
dependable service if operated according to
instructions.
n Read and understand the Owner’s Manual before
operating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
n Be sure to provide adequate ventilation.
Gasoline is extremely flammable and explosive under
certain conditions.
n Always refuel in a well ventilated area with the engine
stopped.
n Keep away from smoking materials, sparks, and other
sources of combustion when refueling the generator.
n Clean up spilled gasoline immediately.
n Restrict operation of generator in high-risk re causing
areas.
Do not touch muffler while it is hot.
n The mufer becomes very hot during operation and remains
hot for several minutes after stopping the engine.
Let the engine cool before storing the generator
indoors.
n The engine exhaust system will be heated during operation
and remain hot immediately after stopping the engine.
n Pay attention to the warning marks attached to the
generator to prevent burns or serious injury.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 6 Page 7
n Always perform a pre-operation inspection before
starting the engine to prevent equipment damage or
accident.
n Place the generator at least three feet (one meter) away
from buildings, or other equipment during operation.
n Operate the generator on a level surface to prevent fuel
spillage and/or oil starvation.
n Know how to stop the generator quickly and understand
operation of all controls. Never permit anyone to operate
the generator without proper instructions.
n Keep children and pets away from the generator while in
operation.
n Keep away from rotating parts while the generator is
running.
n The generator is a potential source of electrical shock
when misused; do not operate with wet hands.
n Do not operate the generator in rain, snow, or anywhere
it is exposed to moisture.
n Never operate the generator with the door open or any
panels removed. Do not operate in any enclosure such
as an RV compartment.
2. Safety Label Locations
CHOKE LEVER
OIL LOCATION
ENGINE SWITCH
HOT
CAUTION
SAFETY CAUTION
MODEL
These labels warn you of potential hazards that can cause serious injury. Read the
labels and safety notes and precautions described in manual carefully.
If a label comes off or becomes hard to read, contact your sales representative for a
replacement.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 8 Page 9
3. Component Identification
Control Panel — IGR1000P
FUEL CAP VENT LEVER
(Non CARB)
FUEL FILLER
CAP
TYPICAL
CONTROL
PANEL
CHOKE
LEVER
MAINTENANCE
COVER
STARTER GRIP
ENGINE SWITCH
SPARK PLUG
MAINTENANCE
COVER
AIR INTAKE
MUFFLER
AIR EXHAUST
OUTPUT
INDICATOR
LIGHT
OVERLOAD
INDICATOR
LIGHT
LOW OIL
ALARM
INDICATOR
LIGHT
GROUND
TERMINAL
OVERLOAD
RESTART
SMART THROTTLE
SWITCH
OVERLOAD
PROTECTOR
HOUR
METER
PARALLEL
OUTPUT
AC RECEPTACLE

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 10 Page 11
Control Panel — IGR2000P Control Panel — IGR2600HP
OUTPUT INDICATOR LIGHT OUTPUT INDICATOR LIGHT
OVERLOAD INDICATOR LIGHT OVERLOAD INDICATOR LIGHT
LOW OIL ALARM
INDICATOR LIGHT
LOW OIL ALARM
INDICATOR LIGHT
GROUND TERMINAL GROUND TERMINAL
OVERLOAD RESTART
OVERLOAD RESTART
SMART
THROTTLE
SWITCH
SMART THROTTLE SWITCH
OVERLOAD
PROTECTOR OVERLOAD
PROTECTOR
HOUR
METER
HOUR METER
PARALLEL
OUTPUT
PARALLEL OUTPUT
AC RECEPTACLE AC RECEPTACLE

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 12 Page 13
Serial Number Identification and Location
The generator serial number identies your
particular unit and is important when ordering
parts and accessories. There is a sticker located
on the top of the unit that displays the serial
number. It is also stamped on the engine block
visible when the service door is removed.
IGR1000P — located to the right of the
engine oil cap.
IGR2000P — located above and to the
right of the engine oil cap.
IGR2600HP — located to the left of the
engine oil cap.
4. Pre-Operation Check
Be sure to check the generator on a level surface with the engine stopped.
Running the engine with insufficient oil can cause serious engine damage.
1. Check the engine oil level.
a. Loosen the cover screw and remove the left side maintenance cover.
b. Remove the oil ller cap, and wipe the oil level indicator with a clean rag.
c. Tighten oil cap and remove again, and check oil level.
d. If the oil level is below the end of the indicator, rell the recommended oil up to
the top of the oil ller neck.
The Low Oil Alarm System will automatically stop the engine before the oil level
falls below the safe limit. However, to avoid the an unexpected shutdown, it is
recommended to inspect the oil level and rell regularly.
UPPER LEVEL
UPPER
LEVEL
UPPER
LEVEL
OIL LEVEL
INDICATOR
OIL FILLER
HOLE
OIL
CAP
MODEL NUMBER
SERIAL NUMBER

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 14 Page 15
2. Check the fuel level.
a. Use automotive unleaded 87-octane gasoline only. Do not use premium or high
octane fuels. Engine is designed to run on regular gasoline. Engine damage and/
or poor performance may result. If the fuel level is low, rell the fuel tank until the
level reaches the specied mark.
b. After refueling, tighten the fuel ller cap
securely.
c. Never use an oil/gasoline mixture or dirty
gasoline. Avoid getting dirt, dust or water in
the fuel tank.
d. A fuel preservative and stabilizer should be added to any container of stored fuel.
Using non detergent oil or 2 cycle engine oil could
shorten the engine’s service life.
n Use a high-detergent,
premium quality 4-stroke
engine oil, certied to
meet or exceed U.S.
automobile manufacturer's
requirements for API
Service Classication SG/
SF.
n Select the appropriate
viscosity for the average
temperature in your area.
SAE Viscosity Grades
Ambient Temperature
RUN
FUEL
FILTER CAP
UPPER LIMIT MARK
Model Fuel Capacity gl. (L)
IGR1000P 0.7 (2.6)
IGR2000P 1.0 (3.78)
IGR2600HP 1.32 (4.9)
n Gasoline is extremely ammable and is explosive under certain conditions.
n Refuel in a well-ventilated area with the engine stopped. Keep all possible
ignition materials, sparks, and any other source of combustion away from the
generator during refueling.
n Do not overll the fuel tank (there should be no fuel above the upper limit mark).
After refueling, make sure the tank cap is closed properly and securely.
n Be careful not to spill fuel when refueling. Make sure the area is dry before
starting the engine. Spilled fuel or fuel vapor may ignite.
n Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP OUT
OF REACH OF CHILDREN.
Gasoline containing alternate fuels
If you decide to use a gasoline containing ethanol, be sure its octane rating is
no lower than the specication. Do not use a blend that contains more than 10%
ethanol. Do not use gasoline containing methanol.
n Fuel system damage or engine performance problems resulting from the use of
fuels that contain an improper alcohol blend are not covered under warranty.
n Before buying fuel from an unfamiliar station, determine if the fuel contains
ethanol and if it does, conrm the type and percentage of ethanol used.
n Replace fuel with proper blend if you experience any undesirable operating
symptoms while using a gasoline that contains ethanol, or one that you think
contains ethanol.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 16 Page 17
2. Check the air cleaner.
a. Check the air cleaner element to be sure it is clean and in good condition.
b. Loosen the cover screw and remove the left side maintenance cover.
c. Press the latch tab on the top of the air cleaner body, remove the air cleaner
cover, and check the air cleaner condition.
d. Clean or replace if necessary.
n Never run the engine without the air cleaner. Rapid engine wear will result from
contaminants, such as dust and dirt, being drawn through the carburetor, into
the engine.
n When starting the generator after adding fuel for the rst time, after long term
storage, or after running out of fuel, turn the fuel valve lever to the “ON” position,
then wait for 10 to 20 seconds before starting the engine.
MAINTENANCE COVER
MAINTENANCE
COVER SCREW
AIR CLEANER BODY
AIR CLEANER
COVER
AIR CLEANER
COVER SCREW
AIR CLEANER ELEMENTS
CARBON CANISTER
5. Starting The Engine
Disconnect any load from the AC receptacle before starting the engine
1. Turn the engine switch to the ON position.
ENGINE SWITCH
START
START
CHOKE LEVER
2. Move the choke lever to the START position.
NOTE: Do not use the choke when the engine is warm or the ambient air
temperature is high.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 18 Page 19
STARTER GRIP
4. Move the choke lever to the RUN position after the engine warms up.
CHOKE LEVER
RUN
RUN
n If the engine stops and will not restart, check the engine oil level before further
troubleshooting.
STOPPING THE ENGINE
1. Switch off the connected equipment and disconnect from the generator.
2. Turn off the engine switch.
EMERGENCY STOP
Turn the start switch to the OFF position.
Continually stopping the generator with a load applied can lead to damage of the
control module.
GROUND TERMINAL
GROUND
MARK
6. Generator Use
Be sure to ground the generator when loads are connected.
n To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy cable between the generator's ground
terminal and an external ground source.
n Connections for standby power to a building's electrical system must be made
by a qualied electrician and must comply with all applicable laws and electrical
codes. Improper connections can allow electrical current from the generator to
back feed into the utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power outage. When utility
power is restored the generator may explode, burn, or cause res in the
building's electrical system.
n Do not connect the generator to an automatic transfer device. Severe damage to
the inverter module may result.
3. Pull the starter grip until resistance is felt then pull the starter grip briskly
toward the arrow as shown below.
n Do not allow the starter grip to
snap back. Return it slowly by hand.
n Do not let the starter rope rub
against the generator body or the
rope will wear out prematurely.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 20 Page 21
n The total wattage of all appliances connected must be considered.
n Do not exceed the current limit specied for any one receptacle.
n Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
n Do not modify or use the generator for other purpose than it is intended for.
n Do not connect an extension to exhaust pipe.
n When an extension cable is required, be sure to use a rubber sheathed exible
cable (IEC 245 or equivalent).
n Limit length of extension cables to 195 feet (60 meters) for cables of 1.5mm² and
325 feet (100 meters) for cables of 2.5mm². Long extension cables will reduce
useable power due to resistance in the extension cable.
n Keep the generator away from other electric cables or wires such as commercial
power supply lines.
n The DC receptacle can be used while the AC power is in use. If both are being
used at the same time, be sure not to exceed the total power for AC and DC.
n Most appliance motors require more than their rated wattage for start-up.
AC application
1. Start the engine and make sure only the output indicator light (green) comes on.
2. Conrm that the appliance to be used is switched off, and plug in the appliance.
OUTPUT INDICATOR LIGHT
PLUG
OVERLOAD
INDICATOR
LIGHT
OUTPUT
INDICATOR LIGHT
(GREEN)
OVERLOAD
INDICATOR LIGHT
(RED)
n Substantial overloading that continuously lights the overload indicator light (red)
may damage the generator. Marginal overloading that temporarily lights the
overload indicator light (red) may shorten the service life of the generator.
n Be sure that all appliances are in good working order before connecting them to
the generator. If an appliance begins to operate abnormally, becomes sluggish,
or stops suddenly, turn off the generator engine switch immediately. Disconnect
the appliance and examine it for signs of malfunction.
Output and Overload Indicators
The output indicator light (green) will remain on during normal operating conditions.
If the generator is overloaded or if there is a short in the connected appliance,
the output indicator light (green) will go out, the overload indicator light (red) will
illuminate and current to the connected appliance will be shut off.
Stop the engine if the overload indicator light (red) comes on and investigate the
overload source
n Before connecting an appliance to the generator, check that it is in good order
and that its electrical rating does not exceed that of the generator. Connect the
power cord of the appliance and start the engine. See page 22 for restoring
electrical power.

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015) MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (073015)Page 22 Page 23
n When an electric motor is started, both the overload indicator light (red) and the
output indicator light (green) may go on simultaneously. This is normal if the
overload indicator light (red) goes off after about four (4) seconds. If the overload
indicator light (red) stays on, consult your generator sales representative.
Overload Reset Switch
Should the generator overload, AC power will be cut off but the engine will stay
running. Correct the overload condition and then press the overload reset switch on
the front panel. AC power will be restored immediately.
DC Operation
The DC receptacle may be used for charging 12 volt automotive style batteries only,
the no load voltage is 15V-30V.
n In DC operation, turn the Smart-throttle switch to the OFF position.
OUTPUT
INDICATOR LIGHT
(GREEN)
OVERLOAD
INDICATOR LIGHT
(RED)
OVERLOAD
RESET SWITCH
APPLIANCE
LOAD
CHARGING CABLE
1. Connect the charging cables to the DC receptacle of the generator and then to
the battery terminals.
n Batteries give off explosive gases; keep spark, ames, cigarettes, and other
sources of ignition away.
n Provide adequate ventilation when charging.
n Batteries contains sulfuric acid (electrolyte). Contact with skin or eyes may cause
severe burns. Wear protective clothing and a face shield.
n Do not start an automobile engine with the generator still connected to the
battery. The generator can be damaged.
n Connect the positive battery terminal to the positive charging cord. Do not
reverse the charging cables, or serious damage to the generator and/or battery
may occur.
n To prevent the possibility of creating a spark near the battery, connect the
charging cable rst to the generator then to the battery. After charging,
disconnect the cable rst at the battery.
n Before connecting charging cables to a battery that is installed in a vehicle,
disconnect the vehicle’s ground battery cable. Reconnect the vehicle's ground
battery cable after the charging cables are removed. This procedure will prevent
the possibility of a short circuit and sparks if accidental contact is made between
a battery terminal and the vehicle's frame or body.