oWTC instruction guide
Assembly, Parts & Hardware List
#6x1/2" Flat Head Screws (x4) #6x1" Flat Head Screws (x4)
What's in the Box
oWTC assembly (PCBA with glass magnets adhered) P/N: 01-00141-1
oWTC Metal wall mounting bracket P/N: 02-00743
Note: color and nish of items will vary.
oAAA batteries (not sold separately)
oOptional WTC 12 VDC Harness 13ft length P/N: 01-00141-2 oHardware kit: Image is example only (not sold separately)

customerservice@modernames.com modernames.com
03
Installation and Assembly
Install Option #1 Battery Powered
2
Separate the wall touch control assembly (attached with magnets) from the metal bracket.
1
Select a suitable location where you would like to install the wall touch control (WTC).
NOTE: It must be within 20 feet of the replace and recommended in the same room for best
performance.
Example

customerservice@modernames.com modernames.com
04
Installation and Assembly
3
Level and cut clearance hole for wall control.
a. If WTC is to be installed into furniture, the inside of included mounting bracket will be
used to mark and cut a clearance hole for the wall controls components. Ensure the bracket is
level prior to marking and cutting the hole.
b. If installed into an existing plaster wall a 2-gang low-voltage old work box (not included)
can be used for installing the touch control. Follow the low voltage old work box manufacturer's
instructions for installing it into the wall.
(Example of hole cut)
(Example of 2-gang low-voltage box)

customerservice@modernames.com modernames.com
05
Installation and Assembly
4
Attach the metal bracket to the furniture or the low-voltage box with the included screws.
NOTE: If other screws are to be used, they must be low prole screws or glass will not secure to
the bracket.
5
Insert two (AAA) batteries paying attention to the polarity on the board. Note: Installing batteries
incorrectly can damage WTC. Batteries cannot be used with wiredapplication or damage to
WTC will occur.
Image is example only

customerservice@modernames.com modernames.com
06
Installation and Assembly
Install the WTC assembly on the bracket. The assembly will be securedby magnets.
7
Pair the wall control with the replace following the pairing instructions on page 13.
6

customerservice@modernames.com modernames.com
07
Installation and Assembly
1
Select a suitable location where you would like to install the wall touch control (WTC). It is
required that this be done prior to nishing the wall, in order to run the cable to the replace
from the desire location.
NOTE: The included cable is 13 feet long so it is recommended the WTC is installed within 10
feet of the replace for ease of installation. The cable can be cut and extended up to 20 feet,
but it is recommended that the WTC be in the same room for best performance. If doing so,
the extension cable should be no smaller than 26 AWG. It is also recommended the extension
be soldered onto cables to ensure reliability of the connection.
2
Ensure the circuit breaker to the replace is OFF.
Example
Install Option #2 Wired

customerservice@modernames.com modernames.com
08
Installation and Assembly
4
Gain access to the inside of the replace and locate the main PCBA. There is an access panel
at the top of viewing area. Front glass must be removed to gain access to main PCBA.
3
Locate the access point on the right side of the firebox and insert the low-voltage cable.
PCBA is inside the
cover
Access
point
- Access panel screws along edge.
- Qty varies by fireplace size.

customerservice@modernames.com modernames.com
09
Installation and Assembly
6
Route the remaining cable to where the WTC will be installed. Take into consideration the
location of the cable so the cable is not damaged when the wall is nished.
5
Locate the previously inserted low-voltage cable and plug it into PCBA. The connection on the
board is labeled "12V+". Do not force connection, if it is not going in rotate 180° and reinsert.
Ensure to leave a few inches of slack for serviceability.
7
Separate the wall touch control assembly (attached with magnets) from the metal bracket.
Connection
on board

customerservice@modernames.com modernames.com
10
Installation and Assembly
8
Level and cut clearance hole for wall control.
a. If WTC is to be installed into furniture, the inside of included mounting bracket will be
used to mark and cut a clearance hole for the wall controls components. Ensure the bracket is
level prior to marking and cutting the hole.
b. If installed into an existing plaster wall a 2-gang low-voltage old work box (not
included) can be used for installing the touch control. Follow the low voltage old work box
manufacturer's instructions for installing it into the wall.
c. If installed into an unnished framed wall a 2-gang low-voltage new work box (not
included) can be used for installing the touch control. Follow the low voltage new work box
manufacturer's instructions for installing it into the wall.
Ensure the cable can be reached.
(Example of hole cut)
(Example of 2-gang low-voltage box)