molex SENSORCON 202312 Manuale utente

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of “Quality Parts,Customers Priority,Honest Operation,and Considerate Service”,our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: [email protected]om Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China

Thank You for choosing The Sensorcon Carbon Monoxide Inspector! We want to be your go to company for all your
professional needs! Please feel free to contact us with any comments, questions or concerns and we’ll do our best to
make sure you’re 100% satisfied.
CONTACT INFORMATION:
425 Essjay Road Suite 100, WilliamsvilleNY, 14221
Office: (716) 566-2728 Fax: (716) 276-3047
www.sensorcon.com
CUSTOMER SERVICE HOURS OF OPERATION:
Monday through Friday: 8am to 4pm
Please Note: East Coast Time Zone
Front View Side View Rear View
INDUSTRIAL PRO CARBON MONOXIDE DETECTOR PRODUCT
WARRANTY:
The Inspector has a one year warranty on all of its parts. It is recommended that you calibrate the Inspector every six
months. If you do not calibrate it then there is a good chance it will not provide an accurate measurement. If a calibration
is never performed an EOL (End of Life) icon will display on the LCD after two years of use. A successful calibration
postpones an EOL for 180 days.
NORMAL OPERATING CONDITIONS:
Temperature: -20oC to +50oC (-4 F to +122 F)
Humidity: 20-90% R.H (0-99% intermittent)
PRACTICAL CONSIDERATIONS:
Short term measurements (i.e. <1hr) in any humidity (0-99% R.H.) are fine as long as condensation does not block the
sensor inlet. A longer term exposure to extreme humidity outside the normal range can cause damage to the sensor.
Damage occurs much faster at higher temperatures. The LCD display and sensor will not work properly at lower
temperatures. NOTE: Higher temperatures can damage the device.
PLEASE NOTE:
Do you know if there is Carbon Monoxide in the air? The Carbon Monoxide Inspector is a professional grade tool that will
answer that question. Carbon Monoxide is a toxic and odorless gas that is produced from most combustion processes.
This includes furnaces, car exhaust and burning cigarettes.
Page 1
Industrial
CERTIFICATION:
ETL CLASSIFIED
THIS DEVICE CONFORMS TO UL STD 913;
CERTIFIED TO CSA STD C22.2 NO 157
Intertek / ETL control number 4004813
PRO
425 Essjay Road Suite 100, WilliamsvilleNY, 14221 Office: (716) 566-2728 [email protected] www.sensorcon.com

CARBON MONOXIDE INSPECTOR QUICKSTART GUIDE
LCD DISPLAY LAYOUT
Page 2
Industrial PRO
425 Essjay Road Suite 100, WilliamsvilleNY, 14221 Office: (716) 566-2728 [email protected] www.sensorcon.com

HOW THE INSPECTOR WORKS:
An electrochemical sensor behind the sensor inlet shown in the image above will create an electrical signal when
carbon monoxide (CO) is sensed. The gas concentration is displayed in parts per million (PPM).
HOW TO PERFORM A SELF CALIBRATION:
For reasonable accuracy a frequent calibration is recommended at least once every 6 months. Sensorcon will
perform this procedure for you or you can do it yourself if you have the necessary 50ppm calibration gas.
Please follow these steps to self calibrate your Inspector:
1. Hold both buttons for 5 seconds to enter calibration mode. Press the MUTE button at any time to exit.
2. In a clean air environment then press the MAX button to begin the ZERO calibration. Wait for countdown.
3. When zero is complete, use 1/4” OD, 1/8” ID Tygon tubing attached to the calibration gas cylinder and
sensor inlet to flow calibration gas at 0.5L/min, then press the MAX button to start calibration process.
4. The Inspector will then automatically calibrate itself and notify you if a calibration is successful.
Please feel free to contact us if you have any further questions or are in need of technical assistance.
Please Note: The Sensorcon Inspector is a professional tool. It does not require very much maintenance with the exception of keeping it clean.
This is especially important in the area of the sensor inlet. If it gets dirty then simply wipe it clean with a damp cloth or with a damp cotton swab.
Sensor Inlet
Hold down both buttons to begin. Connect the 50ppm calibration gas. Wait for the countdown to complete.
Page 3
Industrial
PRO
Industrial
PRO
PRO
Industrial
Industrial
PRO
425 Essjay Road Suite 100, Williamsville NY, 14221 Office: (716) 566-2728 [email protected] www.sensorcon.com
Questo manuale è adatto per i seguenti modelli
1