MONDEX AURA Manuale utente


Stackingthestones 5
Heaterpowerandvoltage 6
Heaterdimensions 6
Requiredamountofstones 6
Minimumdistancestoinammablematerial 7
Note 8
Installationcable 8
Additionalconnectionoptions 8
Firstheating 8
Saunaroom 8
Temperaturecontrol 8
Heatingtime 8
Waterthrownonheater 9
Saunaroomstructure 9
Heaterinstallation 11
Installationofthethermalsensorforthethermostat 11
Controllerinstallation 11
Installationdimensionsofthethermostatand
controller 12
Userinterfacecomponents 14
Menustructure 15
Targettemperature 15
Timersetting 16
Switchingonheater 16
Controllererrorcodes 17
Heaterdoesnotheatup 18
Warnings 18
Warranty 19
Maintenanceandspareparts 19
Naturalstoneasmaterial 19
Changingtheheaterstones 19

1 Electricalconnectionsmayonlybemadebyanelectricianwithvalidinstallationauthorization
accordingtothecurrentregulations.
2 TheMondexelectricheaterissuitableforuseinafamilysauna,one(1)heaterpersaunaroom.
3 Retaintheinstallationandoperatinginstructionsforfurtherreference.
4 Alwayschecktheadequacyofthereprotectiondistances!
5 Failuretoobservetheconnectioninstructionsmayresultinariskofre!
6 Alwayscheckthesaunaroombeforeswitchingtheheateron!
7 Alwayscheckthatthecontrollerhasswitchedtheheateroafterthesettimeperiod!
8 Duetotheriskofre,donotusethesaunatodryclothesorlaundry.
9 Exercisecautionwithahotheater,sincetheheaterstonesandmetalpartsbecomeveryhotand
cancauseburns.
10 Thewatersteamrisingfromtheheaterishotandcancauseburns.
11 Children,disabledandillpersonswhoareusingthesaunashouldbesupervised.
12 Benchesandoorsmaybeslippery,thereforemoveinthesaunawithcaution.
13 Donotgotoahotsaunaundertheinuenceofnarcoticsubstances(alcohol,drugs,
narcotics,etc.).
14 Astonecompartmentwithoutstonesorlledimproperlywillpresentariskofre!
15 Coveringtheheaterwillpresentariskofre.
Thisdeviceisnotintendedforusebypersonswhosephysical,sensoryormentalabilitiesorlackof
experienceandknowledgepreventthemfromusingthedevicesafely,withoutsupervisionorbefore
theyhavebeeninstructedonsafeuseofthedeviceandtheyunderstandthehazardsassociatedwith
usingthedevice.Childrenmaynotplaywiththedevice.Childrenmaynotcleanthedeviceorperform
maintenanceonthedeviceunsupervised.
Mondexpursuesanactivepolicyofproductdevelopmentandcontinuousimprovement.Forthis
reason,Mondexreservestherighttomakechangesrelatingtothedesignandtechnicalspecications
oftheirproductswithoutpriornotice.

Storetheheaterinitsoriginalpackageinan
uprightpositionandinawarmanddrylocation
untilitisinstalled.
Inspecttheheatervisually.Ifyounoticeany
discrepanciesordeciencies,pleasecontactthe
storewhereyoupurchasedtheheaterore-mail
info@mondex.
Theheaterisinstalledsothatitleansagainst
awallusingthebracketprovided(seethe
dimensionsonpage10).
Tofacilitateinstallation,adjusttheheater’sfeet
sothattheyextendout8–9cm.
Leaveagapof5cmbetweentheoorand
theheater!

Useregularolivinediabasegraniteheater
stoneswithdiameteroflessthan10cminthe
Auraheater.Donotplaceceramicheaterstones
intheheater.Wearprotectivegloveswhen
stackingthestones.Stacktheheaterstonesso
thattheresistorsdonotmakecontactwitheach
other.Donotbendtheresistorssothattheyare
incontactwiththemetalstructuresoftheheater.
Stackthestonesinlayersstartingfromthe
bottom.
Continuestackingthe
stonesinthiswayuntilallofthemhavebeen
placed.
.
Dentscausedbytheuserarenotcoveredby
Mondex’swarrantyorotherproductliability.
Whenstackingthestones,becarefulnottodent
theheater’smetalsurfacestoavoiddamaging
them.

6.6kW
400V3N~
5x1.5mm²
3x10A
1010
405
310
5–9m³
70kg
Power
Voltage
Connectingcable
Fuse
Height(mm)
Width(mm)
Depth(mm)
Saunasize
Amountofstones
9.0kW
400V3N~
5x2.5mm²
3x16A
1010
405
310
8–15m³
70kg

900 2,000 100 75
900 2,000 120 75
Ensurethatwheninstallingthesafetycollar,dimensionismeasuredfromthefrontsurfaceofthe
heatertothebenchstructures!

Electricalconnectionsmayonlybemadebyanelectricianwithvalidinstallationauthorizationaccording
tothecurrentregulations.TheAuraelectricheaterissuitableforuseinafamilysauna,one(1)heater
persaunaroom.Retaintheinstallationandoperatinginstructionsforfurtherreference.
UserubbercableH07RN-Fasaconnectioncable.
Controlofelectricheatingwiththeheater:Theelectricheatingcontrolcableisbroughtdirectly
totheheater’sjunctionboxandfurthertotheheater’sterminalblockwitharubbercablethatis
dimensionallyidenticaltotheincomingcable.
Duringtherstheating,theresistorsmayemitfumes.Therefore,ensurethattheroomisproperly
ventilated.NOTE! Please also read the user instructions for the controller!
Alwayscheckthesaunaroombeforeswitchingtheheateron!Alwaysmakesurethatthetimerhas
switchedthepoweroafterthesettimeperiod!
Thetemperatureisadjustedbymeansofthecontroller(seepage15).Theactualheatingtimedepends
onthedimensions,structureandthermalinsulationofthesauna.Thetemperatureinthesaunaroom
canbemaintainedatthedesiredlevelwiththethermostat.Ifthetemperatureofthesaunaroom
becomesdangerouslyhighforanyreason,theoverheatingprotectorwillswitchtheheater’spowero.
Thecauseofoverheatingmustalwaysbeinvestigated.Thepowercanbeswitchedonagainbypressing
theoverheatingprotectorresetbutton(seepage17).
Anexcessiveheatingtimeconsumesenergyanddoesnotimprovethesteamingproperties.Thebest
steamisachievedbykeepingthesauna’sheatingtimerelativelyshort,atabout30–60min.,according
tothesizeofthesaunaandtheheater’spower.Thesizeofthesauna,theglassdoor,windows,or
materialsusedmayrequirealongerheatingtime.

Werecommendusinghandwarmwater.Thewatershouldbefreshhouseholdwater.Throwingthe
waterontotheheatersides/lowerstonesgeneratessoftersteam.Ifyouwantsteamthatfeelshotter
andmoreintense,pourplentyofwarmwaterontopoftheheaterallatonce.
Thesaunaanditsceiling,inparticular,shouldhavegoodthermalinsulation,asheattendstoescape
throughtheceiling.Duetothemoisture,werecommendthatyouusealuminiumpaper.Thesizeofthe
heatershouldbeselectedaccordingtothesizeofthesauna(incubicmetres).Inadditiontocalculating
thepowerneedfortheregularsaunastructure(glasswool–foil–wood),thefollowingshouldbetaken
intoconsideration.Ifthesaunahasanyuninsulatedwood,tileorconcretesurfacesorthewallsare
madeoflogs,theheaterpowerneedstobeincreased.Foreveryuninsulatedsquaremetre,theheater
powerneedincreasesbythesameamountasifincreasingthespacevolumeby1.2m3andontimber
surfacesby1.5m3.Thefactorforglasssurfaces(glasswalls,doorsanduninsulatedstonesurfaces)is
also1.2m3persquaremetre.Inborderlinecases,youshouldchooseaheaterwithhigherpower.
Thesaunaneedsecientventilationforagoodoxygenlevelandasucientamountoffreshair.Theair
inthesaunaneedstochangeatleast6timesperhour.Forasaunawithanelectricheater,mechanical
ventilationisthemostconvenientventilationmethod.Thesupplyairshouldbeprovidedthroughan
inletlocated500mm,ataminimum,abovetheheater,eitheronthewallorintheceiling.Theexhaust
valveshouldbeplacedontheoppositewall,asfarawayfromtheheaterandasclosetotheoorlevel
aspossible.Itishighlyrecommendabletoinstallanexhaustairvalveintheceilingaswellforeasier
removalofmoistureaftersaunasessions.
Formoreinformation,refertotheconstructioninstructionsandbuildingregulations.

71
50 159 7150159
71 50 159 7150159
51.5
51.5
Seepage7fortheheater’sminimumdistancestoinammablematerials.
Keepinmindthattheadjustablefeetaddtothetotalheightoftheheater.
Indice
Altri manuali MONDEX Stufa

MONDEX
MONDEX Kalla Series Manuale utente

MONDEX
MONDEX Tahko 6.6 Manuale utente

MONDEX
MONDEX C-type Guida all'installazione

MONDEX
MONDEX AURA E2 Manuale utente

MONDEX
MONDEX STONE RADIATORS Manuale utente

MONDEX
MONDEX Ahti Series Manuale utente

MONDEX
MONDEX Tahko M Manuale utente

MONDEX
MONDEX Klapi Manuale utente
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro
Stelpro ASILVC2060 Series Manuale utente