1 - Introduction
2 - General warnings
3 - Warranty conditions
4 - Technical and dimensional characteristics
4.1 - Technical characteristics
4.2 - Technical Drawings
5 - Safety warnings
6 - Product identification and technical characteristics
7 - Installation
7.1 - Waste disposal
7.2 - Unpacking and sliding unit movement
7.3 - Minimum safety distances
7.4 - Flue pipe connection
7.5 - The chimney
7.6 - Air intakes
7.6.1 - Natural convention air intake (OPTIONAL art. MORKRX)
7.6.2 - Primary air intake (OPTIONAL art. MORKERM)
7.6.3 - Intakes for heating air
7.6.4 - Decompression nozzle
7.7 - Installation of ventilation kit (OPTIONAL item MORKV720)
7.7.1 - Assembly phases
7.7.2 - Centrifugal fan
7.7.3 - Air grilles
7.7.4 - Hot air ducting
7.7.5 - Control unit
7.7.6 - Installation of thermostatic probe
7.7.7 - Control unit electrical connections
7.8 - Positioning of the fumes deflectors
7.8.1 - Removing the upper deflectors
8 - Use and maintenance of the firebox
8.1 - Recommended fuels
8.2 - Air registers
8.2.1 - Combustion air register
8.2.2 - Combustion air register - FIRE TECH MODE
8.3 - First ignitions
8.4 - Sliding door adjustment
8.5 - Daily use
8.6 - Cleaning and Maintenance
8.6.1 - Daily operations
8.6.2 - Cleaning of the fire pit
8.6.3 - Cleaning of the glass
8.6.4 - Supplied keys (cold hand)

4
1 - INTRODUCTION
Dear customer, thank you for choosing a MORETTI DESIGN product, a cutting-edge product in the field of wood-
burning fireplaces for heating. The great attention to detail during the design phase, the use of advanced technology,
the quality of the materials and the extreme care taken during the processing phase, are the best guarantee of an
efficient, functional, safe and suitable product to fully meet your heating needs.
Moretti DESIGN vented fireboxes are made in compliance with current standards, in accordance with the provisions
of the EN 13229 directive, using certified components, checking the appliance for safety and functionality, and car-
rying out the checks required by law. Moretti is in line with European legislation that allows each product to bear the
CE marking.
For a correct installation of the appliance, for its optimal and safe use and for suitable maintenance, we invite you to
read this manual very carefully, paying particular attention to the warnings below.
2 - GENERAL WARNINGS
This manual has been prepared to allow simple and safe use of the appliance, and is an integral part of MORETTI
DESIGN vented fireboxes; therefore, it is recommended to store it carefully and to always keep it near the appliance
so that it can be consulted when necessary. In case of loss or damage, ask your dealer for a copy.
Installation and maintenance must be carried out by qualified personnel, in compliance with the relevant regulations
and laws in force. All local regulations, including those referring to national and European standards, must be re-
spected when installing and using the appliance.
When installing the firebox, it is mandatory to pay the utmost attention to the instructions provided in this manual.
The installer will assume full responsibility for the final installation and subsequent proper functioning of the installed
product.
For the ordinary operation of the fireplace, the user must apply all the indications obtained from a thorough reading
of this manual. To get started, it's important to know that:
• It is forbidden to install the firebox in environments such as garages, warehouses of combustible material, envi-
ronments at risk of fire or with an explosive atmosphere, rooms where there are liquid fuel heating appliances that
withdraw the vented air from the same room, or in environments where there are type B gas appliances intended
for heating.
• The vented firebox as an incinerator or in any other manner other than that for which it was designed for. No fuel
other than those expressly recommended in this manual should be used. It is absolutely forbidden to use liquid
fuels.
• Some surfaces of the hearth, especially the glazed area, are subject to severe overheating and can cause serious
burns on touch alone. For this reason, together with the fireplace, a special handle is provided for handling the
door and levers. In the absence of the handle, use a special protective glove.
• The use of the firebox by children or persons with reduced physical, sensory and mental capabilities is prohibited,
unless they are supervised and instructed in the use of the appliance by a person responsible for their safety.
Children should be supervised to make sure they are not playing with the appliance.
• Do not perform any unauthorized modifications to the hydro stove. Only use original spare parts recommended by
the manufacturer.
MORETTI FIRE srl is not responsible for the failure of the customer or the installer to comply with the in-
structions, obligations and prohibitions contained in this manual. Any liability of the manufacturer for dama-
ge to persons, animals or property resulting from incorrect installation, incorrect and/or approximate main-
tenance or improper use of the product, not in accordance with the purposes for which it was built, is exclu-
ded.

5
3 - WARRANTY CONDITIONS
The consumer (user of the goods for private use) is the holder of the rights provided for by the Consumer Code - Le-
gislative Decree 206/2005 articles 128-15 (implementation of Directive 1999/44/EC of 25/05/99) and this does not
affect these warranty rights.
The company guarantees the product, with the exception of elements subject to normal wear and tear, for a pe-
riod of 2 (two) years from the date of purchase, which is proven by:
• A supporting document (invoice and/or tax receipt) showing the name of the seller and the date on
which the sale was made.
• Product registration on the website www.morettidesign.it/registrazione-prodotto/
In addition, to make the warranty valid and operational, the installation and commissioning of the appliance must be
carried out exclusively by qualified personnel, who in the cases provided for must issue the user with a declaration of
conformity of the system and proper operation of the product.
If defects of conformity are detected within 2 (two) years of purchase, the seller undertakes to repair the product.
The seller will restore the conformity of the product within a reasonable period of time, taking into account the nature
of the product, the purpose for which it was purchased and the methods to be adopted to restore conformity.
The right to resolve of any non-conformities is not applicable in the following situations:
• failure to comply with the installation and use requirements;
• accidental causes and negligence of the buyer;
• modifications or repairs carried out by unauthorised personnel;
• improper maintenance;
• operation or storage not within the environmental conditions specified for the product;
• damage caused by anomalies on the electrical system, by atmospheric phenomena or by any other cause exter-
nal to the product;
• use in conjunction with accessories not marketed by the seller and/or parts not designed to be used with the pro-
duct.
Parts and materials subject to wear and tampering are excluded from the warranty. Masonry works of any kind, inclu-
ding those for disassembling and reassembling the product, are excluded. In the event of a malfunction, the firebox
will not be replaced but repaired. Moretti Design shall not be held responsible for incorrect assembly or unauthorised
tampering and interventions.
Installations that do not comply with current regulations void the product warranty, such as improper use and non-
maintenance as provided by the manufacturer
Objects NOT covered by warranty
• Iron and vermiculite deflectors;
• Glass;
• Thermostatic probe;
• Centrifugal fan;
• Cast iron slabs;
• Refractory ceramic;
• Control unit if it is opened or tampered with;
• Labour of all kinds;
•

6
4 - TECHNICAL AND DIMENSIONAL CHARACTERISTICS
4.1 Technical characteristics
WARNING: For installation without a ventilation kit, the flue must be positioned at a minimum height greater
than or equal to 21 cm between the support surface and the fire surface. (see page 7)
VENTILATION KIT ART. MORKV720 (OPTIONAL)
WARNING: For the installation of the ventilation kit, MORKV720 (optional), the flue must be positioned at a
minimum height greater than or equal to 36 cm between the support surface and the fire surface. (see page
7)
Description U.M. MONODESIGN LATODESIGN TRIODESIGN
90
60 70 80 90 120 60 RH 60 LH 90 RH 90 LH
Thermal power input kW 19.50 21.80 23.00 24.60 24.60 19.50 19.50 24.60 24.60 24.60
Nominal thermal power kW 17.00 19.00 20.00 21.40 21.40 17.00 17.00 21.40 21.40 21.40
Yield %87.00 87.00 87.00 87.00 87.00 87.00 87.00 87.00 87.00 87.00
CO (13% O2) at nominal power mg/m3 290.00 498.00 498.00 498.00 498.00 290.00 290.00 498.00 498.00 498.00
Exhaust gas temperature C° 198.10 210.30 216.40 225.00 225.00 198.10 198.10 225.00 225.00 225.00
Primary particulate (13% O2)mg/m3 10.0 15.0 15.0 15.0 15.0 10.0 10.0 15.0 15.0 15.0
NOx (13% O2) at nominal
power
mg/m3 79.00 79.00 79.00 72.00 72.00 79.00 79.00 72.00 72.00 72.00
OGC (13% O2) at nominal
power
mg/m3 19.1 29.0 29.0 29.0 29.0 19.1 19.1 29.0 29.0 29.0
Lena consumption Kg/h 4.59 5.15 5.43 5.81 5.81 4.59 4.59 5.81 5.81 5.81
Forced draft Pa 10 10 10 10 10 10 10 10 10 10
Weight Kg 230 245 280 280 290 210 210 280 280 300
Fumes outlet tube mm 202 202 202 202 202 202 202 202 202 202
Primary air inlet duct mm 80 80 80 80 80 80 80 80 80 80
DEC. 186 - 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars 5 Stars
Eco Design - A+ A+ A+ A+ A+ A+ A+ A+ A+ A+
Fuel WOOD LOGS
Minimum distance from flam-
mable and non-flammable
materials
Lateralmm 450 450 450 450 450 450 450 450 450 450
Frontmm 800 800 800 800 800 800 800 800 800 800
Rearmm 450 450 450 450 450 450 450 450 450 450
Description U.M. MONODESIGN LATODESIGN TRIODESIGN
90
60 70 80 90 120 60 RH 60 LH 90 RH 90 LH
Nominal electrical power kW 75 75 75 75 75 75 75 75 75 75
Nominal voltage V230 230 230 230 230 230 230 230 230 230
Nominal frequency Hz 50 50 50 50 50 50 50 50 50 50

7
MINIMUM DISTANCE WITH VENTILATION KIT INSTALLATION
ART. MORKV720 (OPTIONAL)
MINIMUM DISTANCE WITHOUT INSTALLATION OF VENTILATION KIT
(WITH STANDARD FOOT)
360
210
Accessory not supplied. Place a thickness of the
height of 150mm to position the MORKV720 venti-
lation kit box

8
4.2 Technical drawings
MONODESIGN 60
MONODESIGN 70
MONODESIGN 80

9
MONODESIGN 90
MONODESIGN 120
LATODESIGN 60 RH

10
LATODESIGN 90 LH
LATODESIGN 60 LH
LATODESIGN 90 RH
Questo manuale è adatto per i seguenti modelli
9
Indice
Altri manuali Moretti Design Camino da interno