Movisens Move 4 Guida rapida

Move 4
Physical Activity Sensor
Operating and Safety Instructions

2
Imprint
Move 4 Operating and Safety Instructions
Version: 21.08.2019
movisens GmbH
Augartenstraße 1
76137 Karlsruhe
Germany
Phone: +49 721 381344-0
Fax: +49 721 381344-90
Internet: www.movisens.com
E-Mail: [email protected]om
© Copyright: movisens GmbH

3
1Welcome!
Dear customer,
Thank you for choosing the Physical Activity Sensor Move 4 from movisens.
With this sensor, you get the newest technology for mobile monitoring of
physical activity in everyday life.
Please read this manual completely and thoroughly before bringing the
measurement system into service!
In this manual you will find the most relevant operating instructions and the
safety instructions.
Please find the full movisens documentation here:
docs.movisens.com
If you have any further questions, don’t hesitate to contact us. It is our
pleasure to help you:
Phone: +49 721 381344-0
E-Mail: support@movisens.com

4
2Intended use
Move 4 is a scientific research instrument that captures the physical activity
and other secondary parameters derivable from these measurement
signals. Move 4 is designed and tailored for the use in research
applications.
The physical activity sensor Move 4 is not a medical device!
The sensor measures the physical activity of a person based on the
acquisition of acceleration in three dimensions and atmospheric air
pressure. Moreover the sensor also records the rotation rate and the
ambient temperature.
The sensor configuration occurs via a USB 2.0 connection to a Windows PC
using the Sensor Manager software.
3Explanation of Symbols
Caution.
Read the manual and the safety instructions to
find out about possible hazards and the needed
actions to avoid these hazards!

5
4Safety Instructions
Please follow these safety instructions. Improper use of the product may
impair/affect the protection provided by the product and cause product
damage or personal/physical injury:
!Move 4 is not a medical device. Do not use it for a medical
purpose.
!Only use Move 4 for the intended use.
!Carefully read and follow the cleaning instructions.
!For long term measurements (> 1 day) we suggest wearing
pauses of at least 20min per day.
!If any problems occur by wearing the sensor, band, belt or
attachments (e.g. pressure marks, skin irritations or other
discomfort), stop using the system immediately.
!Only use the Move 4 under the specified environmental
conditions.
!To charge the battery of Move 4, only use USB 2.0 standard
compatible devices.
!Charge the sensor only at ambient temperatures below 45°C.
!The use of the cradle is only intended for indoor use.
!Never open Move 4.
!The battery of Move 4 may only be changed by the
manufacturer.

6
5Scope of Delivery
The following components are included in delivery:
Article
Order No.
Move 4
Physical Activity Sensor,
Cradle,
Micro USB cable,
Belt Clip,
Operating and safety instructions
10400
To be able to do measurements a PC is needed in addition to the scope of
delivery.
6Accessories
The following accessories can be ordered optionally:
Article
Order No.
Wrist Band (S)
Size: S
Wrist Measurement: 13 to 16 cm
30431
Wrist Band (M)
Size: M
Wrist Measurement: 15 to 18 cm
30432
Wrist Band (L)
Size: L
Wrist Measurement: 17 to 23 cm
30433
Wrist Band (XL)
30434

7
Size: XL
Wrist Measurement: 20 to 28 cm
Hip Belt
Elastic Belt with SensorFix
Hip Measurement: 67 cm to 125
cm
30412
Cradle 4
Cradle for Move 4
with Micro USB Interface
30400
USB Charger
USB Charger for 110-240V
30100
USB Hub
USB Hub 2.0, 7 Ports
30101
Micro USB Cable
30102
7Consumables
The following consumables can be ordered optionally:
Article
Order No.
Meliseptol Rapid (250 ml)
Ready-to-use alcoholic
disinfectant for spraying or
wiping.
40410
SensorFilm (50 pcs.)
Transparent adhesive film for
attaching the sensors to the skin,
breathable and waterproof,
simple and secure frame
application, size 10 x 12 cm
40402

8
8Description of the Sensor
Depending on the application, Move 4 sensor can be worn in various
locations: hip, chest, wrist, thigh, ankle, upper arm.
For the different sensor locations, the sensor system offers different
possibilities for the analysis of the acceleration signal. The preferred
position for energy expenditure measurements is the hip.
Included in the delivery you also receive a cradle with a micro USB interface.
To connect the sensor to a PC, you have to separate it from the chest belt
or the electrodes and plug it into the cradle.
Move 4 is also equipped with a Bluetooth Smart interface. The sensor can
be used in conjunction with a gateway or a mobile phone for live
applications. The Bluetooth Smart interface is activated in the default
configuration of the sensor. To deactivate this interface, a firmware update
is required.
The axes of the integrated acceleration sensor are defined as described in
the following figure:
9User interface and indicators
Move 4 is equipped with a multi-colored LED to show the status of the
sensor:

9
Status-LED
Meaning
Flashing red (once
per second)
The sensor is active and records
data
Flashing red
slowly (every two
seconds)
Delayed recording active
Flashing green
The sensor is connected to a PC or
a charger. The battery is fully
charged.
Flashing blue
The sensor is connected to a PC or
a charger. The battery is actually
being charged.
Flashing magenta
The sensor is active and records
data. It is connected to a charger.
The battery is actually being
charged.
Flashing yellow
The sensor is active, records data. It
is connected to a charger. The
battery is fully charged.
Flashing blue fast
(three times per
second)
The battery is low, sensor will turn
off soon.
Flashing red fast
(three times per
second)
An Error occurred. Reset the sensor
with the Reset Sensor Program. If
the sensor doesn’t stop flashing,
please contact the manufacturer.
No LED active
The sensor is inactive.

10
Combinations of red and green blinking as well as red and blue blinking are
possible with the appropriate combination of the above described
meanings.
Move 4 features a vibration alarm. It vibrates two times when a marker is
set. During measurement a marker can be set by double tapping on the
front of the sensor.
10 Software Installation
Please ensure that your PC fulfills the requirements:
⚫A PC with Microsoft Windows 7 or higher, 64bit
⚫USB 2.0 Port
⚫Administrator rights during installation
⚫A minimum of 300 MB free space on hard disc
Step 1: Download the SensorManager from the movisens Website
Step 2: Double click the file “movisens_SensorManager_Setup.exe“
✓The Installation runs automatically in the background. After successful
installation, shortcuts are created in the Windows Start Menu under the
entry “movisens SensorManager”.
Step 3: Download the UnisensViewer from the movisens Website:
Step 4: Double click the file “UnisensViewer_Setup_Full.exe“
✓The Installation runs automatically in the background. After successful
installation, a shortcut “UnisensViewer” is created in the Windows Start
Menu.
11 Handling
Altri manuali per Move 4
1
Indice
Altri manuali Movisens Fitness Tracker