Moxy MOXY3 Manuale utente

Owner’s Manual

Introduction
Thank you for purchasing the Moxy Muscle Oxygen Monitor. This manual
covers functionality in Moxy firmware version 1.0 and higher.
Warning:
Always consult your physician before starting or altering any exercise program.
Technical Support:
There is technical support on our Forum at http://forum.moxymonitor.com/.
320-296-1010.
Moxy Software:
Go to www.moxymonitor.com/downloads to download a PC application that
allows you to setup your Moxy and download data from it.
Warning:
There are no user serviceable parts inside the Moxy Sensor. Do not attempt to
open the case.
ANT+ Compatibility:
This product is ANT+™ certified for Muscle Oxygen. Visit
www.thisisant.com/directory/ for a list of compatible products
and apps.
2

Muscle Oxygen Monitoring
Moxy uses Near Infrared Spectroscopy (NIRS) to measure oxygen levels in
muscle. Hemoglobin is the molecule in red blood cells that carries oxygen; it
changes color depending on whether it is carrying oxygen or not. Near-Infrared
light generated by the Sensor travels from the emitter through the skin to
interact with the muscle, after which the light is scattered back to the detectors
in the Sensor. The Moxy Algorithm uses the information from the light striking
the detectors to determine the Muscle Oxygen Saturation.
The terms Muscle Oxygen Saturation, Muscle Oxygenation, and Muscle Oxygen
are the abbreviation, SmO2 are used interchangeably. SmO2is the percentage
of hemoglobin in the capillaries of the muscle that is carrying Oxygen. The
number can be from 0 to 100%. Total hemoglobin, THb, is a relative measure
of the amount of hemoglobin in the optical path of the sensor
Muscle Oxygenation is a localized measurement. Even muscles that are close
to each other, such as the Rectus Femoris and the Vastus Lateralis in the
Quadriceps group, can have different values. Contralateral muscles may also
have different readings.
Muscle Oxygen Monitoring can be used to determine optimal training zones, to
monitor training intensity, and to set an optimal race pace. Refer to the Moxy
website at www.moxymonitor.com for more information.
3

Moxy Overview
4

Moxy Overview
1. On/Off Button. Hold for 3 seconds to turn the sensor on or off. Holding
the button for more than 10 seconds will cause a hard reset of the
sensor microcontroller. A hard reset will not delete any stored data, but
it will reset the clock that is used for time stamps in the stored data.
Short click the button to make the green LED indicate the battery
charge level. A short click also marks a lap in the data stored on the
sensor.
2. Yellow Indicator LED.
On solid indicates connection to the Moxy PC App.
A blink after a short button click indicates that the sensor is on.
3. USB Port. This is a micro USB port. It is used for charging the Sensor or
downloading data.
4. Green Indicator LED. This is used to indicate battery status.
Short blinks while the USB cable is plugged in indicate charging in
progress.
After a short button click, the number of blinks indicates charge
level
5. The ANT+ antenna is located here.
6. Pressure Equalization Vent Port. The port is covered with a waterproof
membrane on the inside.
7. Serial Number. This serial number is used in ANT+ to identify this
individual Moxy sensor. It is also stored in data files to identify which
Sensor acquired the data.
8. Emitter Optode
9. Short-Spacing Optode
10. Long-Spacing Optode
5

Charging the Moxy Sensor
Moxy can be charged with any micro USB charger that has the following
ratings:
oUL or CE markings
o5V DC Output
oOutput Current between 300 mA and 1.0 A
Moxy can also be charged with a computer through a micro USB cable.
Charge time from completely dead to full charge is about 2 hours
The green indicator LED will blink about once per second during normal
charging and it will turn off when the sensor is fully charged.
A short click of the On/Off button will cause the green indicator LED to
blink a certain number of times to indicate the current charge level. 4
blinks indicate fully charged with 3, 2, or 1 blink indicating a lower level
of charge.
The green indicator LED will blink rapidly to indicate a charging fault. To
clear the fault, unplug the micro USB charger cable, make sure the
sensor is turned off, and plug the micro USB charger cable back in. If
the fault persists, the sensor must be returned to the factory for repair.
6

Moxy PC Application
7

Moxy PC Application
The Moxy PC Application is used to set up the Moxy and to download data that
is stored on the Sensor. Go to www.moxymonitor.com/downloads to
download the latest version of the PC application.
1) Connecting to the Moxy Sensor (Sensor can be On or Off)
a. Use a micro USB cable to connect the Sensor to the PC. The
first time you connect a sensor to a PC, it will automatically
download the communication driver. This can take several
minutes.
b. Start the Moxy PC Application and Click on Connect.
c. If there is no COM port showing next to the Connect button
that means the driver download failed. Contact tech support.
2) Setting the Time
a. Refresh shows the current time on the Moxy Sensor.
b. Set sets the Moxy sensor time to match the PC clock time.
c. Note that some display devices will automatically set the Moxy
Sensor time to match the display device time when they pair.
3) Versions –These boxes show the Firmware version and the calibration
information on the Moxy Sensor. Use to Update Firmware button to
load new versions of Firmware on the sensor.
4) ANT+ Profiles –Select the radio button to set which ANT+ profile the
Sensor will use to transmit data.
5) Update Mode –Select the radio button to set the data update rate
mode.
6) Use the Download and Clear Data buttons to for downloading data from
the Sensor and deleting the data on the Sensor.
8

Downloading Data
The Moxy PC Application will prompt you for a file name and location
when you download the data.
The download operation makes a copy of the Sensor data on your PC,
but it does not delete the data on the Sensor. You must click on the
clear data button to delete the data on the Sensor.
DOWNLOADING MAY TAKE SEVERAL MINUTES if there are hours of data
stored on the Sensor.
The data will be saved as 2 files with different formats.
oThe .FIT format is useful for importing the data into other
software packages that support .FIT such as Golden Cheetah.
oThe .CSV file is useful for analysis in software like a
spreadsheet. The .CSV format is:
mm-dd, hh:mm:ss, SmO2Live, SmO2Averaged, THb, Lap
Update Mode
Default Mode has the Moxy sensor calculate new SmO2and THb
readings every 2 seconds. The displayed value is the average of the 5
most recent readings.
Fast Mode has the Moxy sensor calculate a new SmO2reading every 0.5
seconds. There is no averaging.
No Smooth Mode is the same as Default but with no averaging.
Low Power mode is the same as Default except fewer LED cycles are
used so the batter life is extended.
9

Display Live Muscle Oxygen Data
A third party product is required to Display Live Muscle Oxygen Data. Moxy can
transmit data over 3 different ANT+ profiles:
Muscle Oxygen
Heart Rate Monitor
Bicycle Speed and Cadence
The mode you select will depend on the type of display device that you want to
use.
Muscle Oxygen Profile
The Muscle Oxygen Profile is the preferred profile for connecting Moxy to a
display or recording device because it supports all of the functions of the Moxy
Sensor. Follow the instructions with your Muscle Oxygen compatible product
for pairing to the Moxy. The following products have the Muscle Oxygen
Profile capability. Visit www.thisisant.com/directory/ for the latest complete
list of compatible products.
Peripedal –www.peripedal.com
PerfPro –www.perfprostudio.com
IpBike –www.iforpowell.com
Wimu and Quiko –www.realtracksystems.com
SelfLoops - www.selfloops.com
Golden Cheetah –www.goldencheetah.org
Garmin ConnectIQ –www.garmin.com
IT4Cycliing –www.it4cycling.com
Training Mate –www.training-mate.com
Indice