MultiWave Sensors Smart Aligner Manuale utente

USERS GUIDE
V1.1
January 2015

Table of Contents
Section 1 Introduction ........................................................................................................................ 3
Section 2 Safety ................................................................................................................................... 3
Section 3 Approvals ............................................................................................................................. 3
Section 4 What's in the Case................................................................................................................ 4
Section 5 Tool Description.................................................................................................................... 5
Section 6 Arm Positions........................................................................................................................ 6
Section 7 Bracket Description............................................................................................................... 6
Section 8 Bracket Attached to the Antenna.........................................................................................7
8.1 Procedure to Attach the Bracket to the Antenna to be Aligned.............................................. 7
Section 9 Tool Attached to the Bracket............................................................................................... 8
9.1 The 18 Configurations............................................................................................................... 9
9.2 Procedure to Attach the Tool to the Bracket........................................................................... 10
Section 10 Tool LCD Display.................................................................................................................. 11
Section 11 User Menu........................................................................................................................... 12
Section 12 Viewing the Diagnostic and Information Menu................................................................ 12
Section 13 Mobile Device App "Smart Aligner.................................................................................... 13
13.1 Smart Aligner App Flow.......................................................................................................... 13
13.2 App Detailed Description........................................................................................................ 14
13.3 Quick Measure........................................................................................................................ 14
13.4 Site Survey.............................................................................................................................. 15
13.5 Report Example...................................................................................................................... 20
13.6 Settings................................................................................................................................... 21
13.7 Difference Between iOS and Adroid App............................................................................... 21
Section 14 Advanced App Features...................................................................................................... 22
14.1 Import/Export of a csv File..................................................................................................... 22
14.2 Create a Blank/Generic csv File.............................................................................................. 22
14.3 csv File Description................................................................................................................. 23
14.4 User Entered Values............................................................................................................... 23
14.5 Measurement Values.............................................................................................................. 24
14.6 Import a csv Site File.............................................................................................................. 25
14.7 Export a csv Site File............................................................................................................... 25
14.8 Azimuth Tolerance.................................................................................................................. 26
14.9 Laser Rangefinder Measurement for AGL (Option)................................................................ 27
Section 15 Charging the Tool................................................................................................................ 28
Section 16 Optional Brackets............................................................................................................... 29
16.1 Ericsson AIR 21 Bracket........................................................................................................... 29
16.2 GOGO Bracket......................................................................................................................... 30
16.3 Dish Adapter........................................................................................................................... 31
16.4 Edge Adapter.......................................................................................................................... 31
Section 17 Specifications...................................................................................................................... 32
Section 18 Troubleshooting.................................................................................................................. 33
Section 19 Contact, Warranty, Repair and RMA................................................................................. 34

Introduction
The Smart Aligner System is a GPS-based compass designed to effectively and efficiently align antennas in real time. The
Smart Aligner Tool provides a True North or Grid North Azimuth measurement, Tilt, Roll and Position. Once the Tool is
mounted to the antenna using the Universal Mounting Bracket, the Tool is simply turned on. From there the user
interface is the full feature App on any iOS or Android smart device. Reporting is as simple as a few clicks with the report
being able to be emailed directly from the App. The Tool can be mounted in eighteen different configurations for the
most demanding spatial and RF conditions. For transport and storage the Tool folds to within 19” in length.
DOWNLOAD THE iOS Smart Aligner App from the App Store by searching for “Smart Aligner Multiwave”
DOWNLOAD the Android Smart Aligner App from Google Play by searching for “Smart Aligner Multiwave”
1
Safety
2
When transporting/carrying the Smart Aligner System up a tower follow all relevant safety procedures and requirements.
Always use the tether lines as described in this manual.
Use supplied or approved chargers (12VDC – 1.5A) to charge the battery.
Approvals
3
Declaration of Conformity
We declare that this product has been tested to and meet the requirements of:
EMC
FCC Part 15 Subpart B: 2008
EN 61326-1
ICES-003:2004
Safety
EN 61010-1
RoHS and WEEE Compliance
The European Union has legislated to enforce the RoHS and WEEE directives.
RoHS : Restriction of certain Hazardous Substances in electronic equipment.
WEEE: Waste Electrical and Electronic Equipment.
Multiwave Sensors Inc. can confirm to the best of our knowledge that the Smart Aligner System is compliant with the
above directives.
In the event that the Smart Aligner battery does not charge properly, call Multiwave Sensors Inc., and if required the
Smart Aligner System should be sent back to Multiwave Sensors Inc. for repair and proper disposal of the battery.
3
WARNING

What is in the Case
Ruggedized Carrying Case
Backpack
Smart Aligner Tool
Slot forOptions: Laser Rangefinder,
AIR 21 Mounting Bracket, Custom
Brackets
Wall Charger
Universal Mounting Bracket
Slot for Smart Phone:
Smart Phone not included
4
Car Charger
Ruggedized Carrying Case: All components fit in the case. The case is carry on baggage acceptable.
Backpack: To carry the Smart Aligner Tool and Brackets. Two separate compartments within.
Smart Aligner Tool: For measuring Azimuth, Tilt, Roll and Position of Antenna.
Slot for Options : Laser Rangefinder for measuring AGL, AIR21 Mounting Bracket, Custom Brackets
Universal Mounting Bracket: Bracket that attaches to Antenna. Smart Aligner Tool attaches to
Bracket. Combined Bracket and Tool to align the antenna.
Smart Phone slot: For iPhone or Android based Smart Phone.
Wall Charger: For charging the Smart Aligner Tool.
Car Charger: For charging the Smart Aligner Tool.
4
NOTE: Throughout this Guide the “Smart Aligner Tool” will be referred to as the “Tool”
The “Universal Mounting Bracket” will be referred to as the “Bracket”

Tool Description
5
Long Arm
Tether Line/Pin
Mounting Screw Knob
User Interface
Mounting Dowel Pins
(underside)
Short Arm
Charging Port
Data/Laser Port
Short Arm: Contains first GPS antenna. From stored position: Rotates to +90° and 180° OR -90° and 180°
Long Arm: Contains Second GPS antenna. From stored position: Stored position to +90° OR Stored Position to -90°
Charging Port: Port for Wall or Car Charger
User Interface : LCD Screen, Menu Buttons and Power Button
Tether Line/Pin: Attaches to Bracket
Mounting Screw Knob: Attaches to Mounting Screw Knob receptacle on Bracket
Mounting Dowel Pins: Attaches to Dowel Pin Receptacles on Bracket
Data/Laser Port: Used with Laser Rangefinder option for AGL measurement
Power Button
Power LED indicator
Menu Enter Button
Up/Down Buttons
LCD Display
User Interface
5

Arm Positions
6
The Long Arm and Short Arm each contain a GPS antenna. The arms can be rotated to three different fixed baseline
positions. Each position sets the two GPS antennas at a separation of 0.5m for optimum accuracy. The “T” positions
also extend the baseline away from the antenna that is being aligned to minimize or eliminate GPS multipath errors.
For each of the positions the Tool compensates the Azimuth measurement so that the Azimuth is always calculated
based on the Forward position. For example: If the Forward azimuth is 0° then moving the arms to the Left T position
would point the arms at 270°. Sensors in the arms detect the rotation and compensate the azimuth +90° back to 0°
(or 270° + 90° = 360° = 0°). In the Right T position the arms would point at 90°. Sensors in the arms detect the
rotation and compensate the azimuth -90° back to 0° (or 90° - 90° = 0° ). When the Tool is mounted on the Bracket
there are sensors that compensate the Azimuth based on how the Tool is mounted. Tilt and Roll are also compensated
in all configurations.
Forward Left T Right T
Bracket Description
7
Strap Release (orange button)
Ratcheting Handles
Dowel Pin Receptacles x 4
Mounting Screw Knob Receptacle
Tether Line
(to mast or other solid location) Tether Line Receptacle (from Tool)
Ratchet Strap Fastening Pins
Ratchet Strap with hook
Ratchet Strap Fastening Pins: Ratchet Strap hook attaches to Pin.
Ratchet Strap with hook: Strap goes around the front of the antenna and hook is attached to the Fastening Pins
Dowel Pin Receptacles: The two Mounting Dowel Pins on the Smart Aligner Tool mate to two Dowel Pin Receptacles
on the Bracket. The Tool can be attached Front or Back or Right/Left.
Mounting Screw Knob Receptacle: Mounting Screw Knob on Smart Aligner Tool is secured here.
Ratcheting Handles: When handles are ratcheted the strap is tightened around the antenna to be aligned.
Strap Release: Releases tension on Strap.
Tether Line Receptacle (from Tool): Tether Line from Smart Aligner Tool is secured here.
Tether Line (to mast or solid location): Tether Line is secured to the mast or any solid location
The Bracket attaches to the antenna to be aligned. The Tool attaches to the Bracket by mating the Mounting Dowel Pins
on the Tool to the Dowel Pin Receptacles on the Bracket. The Bracket can be attached to the left or right side of the
antenna (right side position is shown). The Tool can be attached in three different positions on the Bracket. Sensors in the
Bracket compensate the Azimuth based on the three different positions.
6

Bracket Attached to the Antenna
8
The Bracket is shown mounted on the right side of the antenna to be aligned. The Bracket can also be mounted on the left
side of the antenna. The four Dowel Pin Receptacles on the Bracket allow for attaching the Tool facing Front, Back or
Right. If the Bracket was mounted on the left side of the antenna then the Tool can face Front, Back or Left. Sensors in
the Bracket compensate for the Azimuth due to the different positions of the Tool.
Dowel Pin Receptacles for Front facing Tool
Dowel Pin Receptacles for Right facing Tool
Dowel Pin Receptacles for Back facing Tool
1. Tether the Bracket to a solid location.
2. Set the Bracket on the backplane of the antenna as shown.
Keep the Bracket in place by holding on to the handle.
3. Depress the orange Strap Release button with your thumb and hold it
4. With your other hand attach the hook of the Ratchet Strap to
the appropriate Ratchet Strap Fastening Pin
6. Squeeze the Ratcheting Handles until the Bracket is
tight to the antenna
5. Release the orange Strap Release button but still hold the
Bracket
Procedure to Attach the Bracket to the Antenna to be Aligned
7. You are now ready to attach the Tool to the Bracket
1
2 3,5
4
6
8.1
7

Tool Attached to the Bracket
9
Right side of antenna: Tool facing Front, Arms Left T
Right side of antenna: Tool facing Right, Arms Right T
The Tool and Bracket can be attached to the antenna in 18 different configurations.
The 18 configurations are:
1-2 Right or Left side of antenna: Tool facing Front on Bracket, Arms Forward
3-4 Right or Left side of antenna: Tool facing Front on Bracket, Arms Left T (shown below)
5-6 Right or Left side of antenna: Tool facing Front on Bracket, Arms Right T
7-8 Right or Left side of antenna: Tool facing Right on Bracket, Arms Forward
9-10 Right or Left side of antenna: Tool facing Right on Bracket, Arms Left T
11-12 Right or Left Side of antenna: Tool facing Right on Bracket, Arms Right T (shown below)
13-14 Right or Left side of antenna: Tool facing Back on Bracket, Arms Forward
15-16 Right or Left side of antenna: Tool facing Back on Bracket, Arms Left T
17-18 Right or Left Side of antenna: Tool facing Back on Bracket, Arms Right T (shown below)
Right side of antenna: Tool facing Back, Arms Right T
8

The 18 Configurations
9.1
Antenna Azimuth
No matter which configuration the Tool and Bracket are mounted to the antenna the Antenna Azimuth will be
compensated. The user does not need to set any offsets. Sensors in the Bracket and Tool detect the configuration and
automatically compensate the Azimuth, Tilt and Roll of the antenna. The different configurations are useful when there
are mechanical constraints or excessive RF radiation from a live antenna. The T positions allow for extension of the two
GPS antenna elements away from the antenna to mitigate any GPS multi-path effects which will degrade accuracy.
9

Procedure to attach the Tool to the Bracket
Example is for Right side of antenna: Tool facing Front, Arms Left T
1. Tether the Tool to the Bracket
2. Line up the Mounting
Dowel Pins (underside of
Tool) to the Dowel Pin
Receptacles on the Bracket
3. Tighten the Mounting
Screw Knob on the Tool
4. Rotate Short Arm clockwise till
you feel/hear it click in and engage
5. Rotate the Long Arm
counter-clockwise till you
feel/hear it click in and
engage
6. Press the POWER
button on the User Interface
and wait for an azimuth
solution
7. See next section for
description of what you will see
on the LCD User Interface Screen
and how to navigate the menu
items
1
5
2,3
4
6
4
5
9.2
10
Altri manuali per Smart Aligner
1
Indice