Muncie OMNI-SYSTEM Guida rapida

OMNI-SYSTEM
SNOW & ICE DIVISION
OPERATION AND
CONFIGURATION MANUAL

PAGE 1 OMNI-SYSTEM

SNOW & ICE DIVISION PAGE 2
TABLE OF CONTENTS
Features and Specications.........................................................................................................4
Controller Pinnouts.......................................................................................................................5
Operation Screens.........................................................................................................................6
Controller Alerts ............................................................................................................................7
Accessing Conguration..............................................................................................................8
Conguration Menu—Software/Passcode Reset .......................................................................9
Conguration Menu—Datalogging Menu..................................................................................10
Conguration Menu—Spreader Settings .................................................................................. 11
Conguration Menu —Dump Settings........................................................................................13
Conguration Menu—Plow Settings .........................................................................................14

PAGE 3 OMNI-SYSTEM

SNOW & ICE DIVISION PAGE 4
FEATURES & SPECIFICATIONS
Controller Specications
• Voltage Input Range (10VDC—16.5VDC)
• Max Operating Current (1.5 Amps)
• Open and Short Circuit Protection
• CAN Communication Protocol
Electrical System Features
• Congurable Error Status Indicators
• Upgradeable Software
• AVL System Ready
• Ground Speed Orientation
• Open & Short Circuit Protection and Alerts
• Expandable I/O
• Adjustable LED Backlighting
• Tactile Switch Controls
• Built-in Audible Alarm
• Air & Road Temperature Sensor Ready

PAGE 5 OMNI-SYSTEM
CONTROLLER PINOUTS
Main Controller
Connector
USB Port
1
6
10 14
5
9
Pin Function Comment
A.1 CAN0 L
No term
A.2 CAN0 H
A.3 CAN1 L
120 term
A.4 CAN1 H
A.5 +5VOUT 0.5A MAX
A.6 N/A
A.7 N/A
A.8 J1708 A
A.9 J1708 B
A.10 +VIN
A.11 GND
A.12 DIG1 GND Trigger
A.13 DIG2 Selectable +/-
A.14 DIG3 Selectable +/- or PWM
Detailed enlarged drawing of the
Main Controller Connector.

SNOW & ICE DIVISION PAGE 6
ON–OFF CONTROLS:
Controller on-off: The controller is powered through a
keyed ignition switch.
Spreader on-off: Depress the auger and liquid knobs
to activate the auger and spinner. Rotate the auger
and spinner knobs to increase the rates to the desired
settings. Rates will be displayed in the displays above
the adjustment knobs.
Liquid on-off: Depress the liquid and spinner knobs
to activate the pre-wet system. Rotate the liquid knob
to increase the rate. The rate will be directly displayed
above each encoder adjustment knob.
SPREADER OPERATION:
Blast: Press the auger knob to “Blast” granular
material. Both the granular rate and time are
adjustable in the conguration menu. See Page
11 for additional information on this.
Pause: Press the spinner knob to pause all
spreader operations.
Operating Mode: Depress the liquid knob to change
operating modes.
• Auto: The material output is spread in proportion
to vehicle speed (lbs./mile). When the truck
stops, the salt stops. A ashing Auto display
indicates the system is at 0 MPH or not receiving
a groundspeed input.
• Manual: The material output is spread at a xed
percentage rate.
Brightness: To adjust the brightness of the display
and buttons:
(1) Depress and hold the liquid knob for 6 seconds
until a numerical value appears in the spinner window.
(2) Rotate the spinner encoder to adjust the intensity
of the backlighting.
DISPLAY:
Air Temp/Road Temp – When the system is equipped
with an IR temperature sensor, the controller will
display the air and road temperatures.
Totals – Displays the granular material totals.
FEATURES AND SPECIFICATIONS
Granular
Totals
Air/Road
Temperatures
Joystick
Mode
Alert
Joystick Mode – Displays the current piece of equipment the
joystick is controlling.
Alerts – Displays error messages.
CYLINDER OPERATION:
Plow: Push the appropriate arrowed buttons to operate.
Vertical oriented arrows will raise and lower the plow. Lateral
oriented arrows will angle the plow.
Float Operation: When equipped with plow oat, quickly
depress the down arrow twice to activate. Depress the up
arrow or pull back on the joystick to disengage the oat
functionality.
Dump: Push the appropriate arrowed buttons to operate the
dump body. The up arrow will raise the body, and the down
arrow will lower the body.
Backlighting: The arrowed buttons will change from
green to red to indicate the action has been successfully
communicated to the valves.
Fault Detection: Alternating green and red lights on the
arrowed buttons indicate a fault with the attempted function.
This could be a short or open circuit.

PAGE 7 OMNI-SYSTEM
CONTROLLER ALERTS
Cylinder Button Errors: Alternating green and red
lights on an individual arrowed button indicates a
fault with the particular function. Check the electrical
connector at the associated solenoid valve.
When all buttons appear to ash individually,
this typically indicates a fault with the unloader /
electrically controlled main relief output. This could
also indicate the I/O modules are not connected.
Spreader Display Errors: Whenever an open or
short is detected at one of the spreader outputs,
ERR will appear in the display of the problematic
function. Check the connection of the designated
solenoid valve to resolve.
Ground Speed Indicator: A ashing spreader
display will indicate the unit is operating within auto
mode and is not receiving a MPH signal. Keep in
mind the controller will not be receiving a MPH
signal when the truck is not moving.
Alert Display: The alert display will provide
messages tied to the systems digital inputs. Pending
the conguration selected, the system has the ability
to alert the operator when there is a hot oil, low oil,
body up, and/or lter bypass condition.
ERR will also appear on the alert display in the event
a joystick has been disconnected.
Cylinder
Buttons
Alert
Display
Spreader
Display

SNOW & ICE DIVISION PAGE 8
CALIBRATION SCREENS
ACCESSING CONFIGURATION MENU:
This menu is passcode protected to limit access
to non-authorized personnel. It is recommended
to change the passcode from the default value
to limit access and prevent unintentional system
adjustments.
Follow the steps below to enter the conguration menu:
1. Accessing Cong Menu: With the spreader
off, simultaneously depress the Auger and
Spinner knobs.
2. Passcode Entry: The liquid knob will adjust the
left 2 digits and the spinner control will adjust the
right 2 digits.
(Default Passcode = 0001)
3. Navigating Conguration Menu:
• Rotate the auger knob to scroll through the
various adjustment items.
• To enter and exit the sub menus, depress the
auger knob.
• To change settings, rotate the liquid and
spinner knobs.

PAGE 9 OMNI-SYSTEM
CALIBRATION SCREENS
SOFTWARE MENU:
Firmware Bundle: Non-adjustable and reference
only.
Firmware Panel: Non-adjustable and reference
only.
Firmware HMI: Non-adjustable and reference only.
Firmware Primary: Non-adjustable and
reference only.
Firmware Secondary: All rmware menus are non-
adjustable and reference only.
Firmware Liquid Mod: All rmware menus are non-
adjustable and reference only.
Passcode Change: Using the liquid and spinner
knobs, adjust the default passcode.
SOFTWARE
FIRMWARE BUNDLE
4.0
FIRMWARE PANEL
4.0.89
FIRMWARE HMI
4.0.25
FIRMWARE PRIMARY
0
FIRMWARE SECONDARY
0
FIRMWARE LIQUID MOD
0.0.0
PASSCODE
CHANGE 0001