MYTORQ MY-TR Manuale utente

ELECTRIC
SCREWDIVERS
N-DAS FOR MY-TR
System Operation Manual
Y2F210-5-009
2022/01/26

Page 2 of 46
ELECTRIC
SCREWDIVERS
Table of Contents
①User Guide...................................................................................................................................3
②System Requirements................................................................................................................4
③Hardware......................................................................................................................................5
④System Connection.....................................................................................................................6
⑤System Screen Introduction ......................................................................................................9
➢Unlock Settings....................................................................................................................9
➢Password change setting method...................................................................................10
➢Restore default password ................................................................................................10
1. Product setup page...........................................................................................................11
2. Controller and Job setup page.........................................................................................28
3. Barcode Manager................................................................................................................32
4. Report and trend graph setup page.................................................................................34
5. Instant data display.............................................................................................................37
⑥Remote Screen..........................................................................................................................38
⑦System Function Setup............................................................................................................39
⑧Info Company Website.............................................................................................................41
⑨Example Description.................................................................................................................42
⑩Statement...................................................................................................................................46

Page 3 of 46
ELECTRIC
SCREWDIVERS
①User Guide
This manual describes how to quickly operate the “Data Acquisition System”
and get started with the MY-TR controller.
Diversified operation interface, user-friendly design also system can have
functions such as report operation, data analysis, trend graph, parameter setting,
etc.

Page 4 of 46
ELECTRIC
SCREWDIVERS
②System Requirements
⚫Windows 10, Windows 8, Windows 7, Windows XP or Windows Vista
⚫Hardware memory at least 768MB/2GBHz processor
⚫At least 2GB hard disk
⚫Recommended at least 16-bit color and 1024x768 screen resolution
⚫.NET Framework 4.0 or above must be installed

Page 5 of 46
ELECTRIC
SCREWDIVERS
③Hardware
1. The following must be prepared before operating this system:
⚫MY-TR Controller
⚫Executable file for the operating
Data_Acquisition_System.exe.
⚫One RS-232 serial port.
⚫One 1D(Linear) barcode scanner (*not necessary).
2. Device connection as in the following diagram:
PC
Barcode scanner
PORT2
RS-232
RS-232
PORT1
MY-TR

Page 6 of 46
ELECTRIC
SCREWDIVERS
④System Connection
Step 1: Before log in, it is required to set the date format in the computer system
as “YYYY/MM/DD”.
Step 2: Download the compressed software
NOTE:
For the version: 1.0.0.6 and later on, there must have 2 additional dll files in the
folder(shown as below picture) after you decompressed the software. These are
required files to run the software.
Step 3: Open the executable file Data_Acquisition_System.exe.

Page 7 of 46
ELECTRIC
SCREWDIVERS
Step 4: Move the mouse cursor to and display the four
controllers.
Step 5: Controller selection (MY-TR)

Page 8 of 46
ELECTRIC
SCREWDIVERS
Step 6: Go to Comm page.
port to pull down
(Connect according to the port of the computer display device)
And press and leave controller product testing setup page
(communication settings are default, there is no need to modify).
A
B

Page 9 of 46
ELECTRIC
SCREWDIVERS
⑤System Screen Introduction
➢Unlock Settings
The page displayed is Instant data display after entering the screen. At this time,
no operation can be performed due to locked setting. You must enter the
password first if need to unlock for operation.
Step 1: After clicking the button of "Edit Settings", the unlock window will pop
up.
Step 2: Enter the default password "admin123" and click confirm button.
1
2

Page 10 of 46
ELECTRIC
SCREWDIVERS
➢Password change setting method
Click "Edit Settings" button → "Edit Password" to enter the old password and
the new password, and then click OK button to complete the setting.
NOTE: New password setting: Six to eight characters in length, including
English uppercase and lowercase, numbers.
➢Restore default password
Select to enter the Setting folder, delete the file named Setup and
Reopen it Data_Acquisition_System can restore the default password
(admin123)
2
3
1
1
2
3
1
2
3