NARDA PMM AS02 Manuale utente

NARDA
Safety
Test
Solutions
S.r.l. Socio Unico
Sales & Support:
Via Leonardo da Vinci, 21/23
20090 Segrate (MI) - ITALY
Tel.: +39 02 2699871
Fax: +39 02 26998700
Manufacturing Plant:
Via Benessea, 29/B
17035 Cisano sul Neva (SV)
Tel.: +39 0182 58641
Fax: +39 0182 586400
http://www.narda-sts.it
SERIAL NUMBER OF THE INSTRUMENT
You can find the Serial Number near the RF connector on both antennas.
Serial Number is in the form: 0000X00000.
The first four digits and the letter are the Serial Number prefix, the last five digits are
the Serial Number suffix. The prefix is the same for identical instruments, it changes
only when a configuration change is made to the instrument.
The suffix is different for each instrument.
Document ASEN-81109 - Copyright NARDA 2018
User’s Manual
PMM AS02
PMM AS03
PMM AS04
PMM AS05
PMM AS06
PMM AS07
PMM AS08
ANTENNA SET

II Note and symbols
NOTE:
If the instrument is used in any other way than as described in this Users Manual, it may become unsafe
Before using this product, the related documentation must be read with great care and fully understood to
familiarize with all the safety prescriptions.
To ensure the correct use and the maximum safety level, the User shall know all the
instructions and recommendations contained in this document.
This product has a Pollution Degree II normally only non-conductive pollution occurs. Occasionally,
however, a temporary conductivity caused by condensation must be expected.
The information contained in this document is subject to change without notice.
KEY TO THE ELECTRIC AND SAFETY SYMBOLS:
You now own a high-quality instrument that will give you many years of reliable service.
Nevertheless, even this product will eventually become obsolete. When that time comes,
please remember that electronic equipment must be disposed of in accordance with local
regulations. This product conforms to the WEEE Directive of the European Union
(2002/96/EC) and belongs to Category 9 (Monitoring and Control Instruments). You can
return the instrument to us free of charge for proper environment friendly disposal. You
can obtain further information from your local Narda Sales Partner or by visiting our
website at www.narda-sts.it .
Warning, danger of electric shock
Earth
Read carefully the Operating Manual and its
instructions, pay attention to the safety symbols.
Unit Earth Connection
Earth Protection
Equipotential
KEY TO THE SYMBOLS USED IN THIS DOCUMENT:
DANGER
The DANGER sign draws attention to a potential risk to a person’s safety.
All the precautions must be fully understood and applied before
proceeding.
WARNING
The WARNING sign draws attention to a potential risk of damage to the
apparatus or loss of data. All the precautions must be fully understood
and applied before proceeding.
CAUTION The CAUTION sign draws attention against unsafe practices for the
apparatus functionality.
NOTE: The NOTE draw attention to important information.

Contents III
Contents
1 General information Page
1.1 Introduction................................…...............................…… 1-1
1.2 Documentation…................................................................ 1-1
1.3 Introduction to the PMM Antenna Set…………..………….. 1-1
1.4 Standard accessories.………………………………….……. 1-2
1.4.1 PMM AS-02 Antenna Set…………………………………. 1-2
1.4.2 PMM AS-03 Antenna Set…………………………………. 1-3
1.4.3 PMM AS-04 Antenna Set…………………………………. 1-4
1.4.4 PMM AS-05 Antenna Set…………………………………. 1-5
1.4.5 PMM AS-06 Antenna Set…………………………………. 1-6
1.4.6 PMM AS-07 Antenna Set…………………………………. 1-7
1.4.7 PMM AS-08 Antenna Set…………………………………. 1-8
1.5 Optional accessories………………………………............. 1-9
1.6 PMM BC-01 Biconical Dipole Antenna……………………. 1-10
1.7 PMM BL-01 Biconical Log Periodic Dipole Array............. 1-11
1.8 PMM LP-02 Log Periodic Dipole Array…………………… 1-12
1.9 PMM LP-03 Log Periodic Dipole Array…………………… 1-13
1.10 PMM LP-04 Log Periodic Dipole Array …………………. 1-14
1.11 PMM DR-01 Double Ridged horn antenna……………… 1-15
1.12 BC-01 Main Specifications………………………………… 1-16
1.13 BL-01 Main Specifications………………………………… 1-19
1.14 LP-02 Main Specifications………………………………… 1-21
1.15 LP-03 Main Specifications………………………………… 1-25
1.16 LP-04 Main Specifications………………………………… 1-27
1.17 DR-01 Main Specifications……………………………….,. 1-29
1.18 TR-01 Main Specifications……………………………….., 1-31
1.19 RF Cable 5m Main Specifications……………………..,,, 1-32
2 Mounting Instructions Page
2.1 Introduction…………………………………………………… 2-1
2.2 Initial inspection………………………………………………. 2-1
2.3 Environment………………………………………………….. 2-1
2.4 Return for service…......................................................... 2-1
2.5 Equipment cleaning…………………………………….…… 2-1
2.6 PMM BC-01 Biconical Dipole Array.................................. 2-2
2.7 PMM BL-01 Biconical Log Periodic Dipole Array.............. 2-3
2.8 PMM LP-02 Log Periodic Dipole Array............................. 2-7
2.9 PMM LP-03 Log Periodic Dipole Array ………………...... 2-8
2.10 PMM LP-04 Log Periodic Dipole Array………………….. 2-10
3 Radiated Emission and Immunity testing Page
3.1 Radiated emission testing.................................................
3.1.1 The receiver antenna………………………………………
3.1.2 The interconnecting cable…………………………….......
3.1.3 The preamplifier……………………………………………
3.1.4 The preamplifier interconnecting cable………………….
3.1.5 The meter receiver…………………………………………
3-1
3-1
3-1
3-1
3-1
3-2
3.2 Radiated immunity testing...............................................
3.2.1 The signal generator………………………………………
3.2.2 The power amplifier……………………….………………
3.2.3 The transmit antenna……………………………………..
3.2.4 The field strength meter…………………………………..
3-3
3-3
3-3
3-3
3-3
3.3 Environmental testing……………………………………….. 3-5

IV Contents
Figures
Figure
Page
1-1 PMM AS-02 kit…….……………………………………….. 1-2
1-2 PMM AS-03 kit…….……………………………………….. 1-3
1-3 PMM AS-04 kit…….……………………………………….. 1-4
1-4 PMM AS-05 kit…….……………………………………….. 1-5
1-5 PMM AS-06 kit…….………………………………………. 1-6
1-6 PMM AS-07 kit…….……………………………………….. 1-7
1-7 PMM AS-08 kit…….……………………………….………. 1-8
1-8 PMM BC-01…………………………………………………... 1-10
1-9 PMM BL-01…………………………………………………... 1-11
1-10 PMM LP-02…………………………………………………… 1-12
1-11 PMM LP-03…………………………………………………… 1-13
1-12 PMM LP-04…………………………………………………. 1-14
1-13 PMM DR-01………………………………………………… 1-15
1-14 Typical BC-01 antenna factor @ 3 m……...................... 1-17
1-15 Typical BC-01 antenna factor @ 10 m……..................... 1-18
1-16 Typical BL-01 antenna factor …….................................. 1-19
1-17 Typical BL-01 VSWR ………………….……..................... 1-20
1-18 Typical LP-02 antenna factor @ 3 m……....................... 1-22
1-19 Typical LP-02 antenna factor @ 10 m………………..…. 1-23
1-20 Typical LP-02 VSWR …………………………………...... 1-24
1-21 Typical LP-03 Antenna Factor ………………………..…. 1-25
1-22 Typical LP-03 Gain .………………………………………. 1-26
1-23 Typical LP-03 VSWR ……………………………..……… 1-26
1-24 Typical LP-04 Antenna Factor …………………..……… 1-27
1-25 Typical LP-04 VSWR ………………………….………… 1-28
1-26 Typical DR-01Antenna Factor ..…………………..……. 1-29
1-27 Typical DR-01VSWR ……………………………………. 1-30
1-28
1-29
1-30
Mounting head with center column...................................
Adjustable joint……..………………………………….…….
Typical RF Cable/5 insertion loss...…………………….….
1-31
1-31
1-32
2-1 PMM BC-01 with TR-01………...………………………….. 2-2
2-2 PMM BL-01 with TR-01………...…………………….……. 2-3
2-3 PMM LP-02 with TR-01………...………………………..… 2-4
2-4 PMM LP-03 with TR-01………...……………………..…… 2-6
2-5 PMM LP-04 with TR-01……………………………………… 2-7
3-1 Radiated emission test setup………………………………. 3-2
3-2 Radiated immunity test setup………………………………. 3-4
3-3 Environmental test setup……………………………………. 3-5
Tables
Table
Page
1-1
1-2
1-3
PMM BC-01 Biconical Dipole Specifications....................
PMM BL-01 Biconical Dipole Specifications....................
PMM LP-02 Log Periodic Dipole Array Specifications......
1-16
1-19
1-21
1-4 PMM LP-03 Log Periodic Dipole Array Specifications...... 1-25
1-5
1-6
PMM LP-04 Log Periodic Dipole Array Specifications.....
PMM DR-01 Double ridged Antenna Specifications …….
1-27
1-29
1-7 PMM TR-01 Wooden Tripod Specifications…………….. 1-31
1-8 PMM RF Cable / 5 Specifications……………………..….. 1-28

General information 1-1
1 – General Information
1.1 Introduction
This manual is a guide to the installation and use of the PMM AS-02, AS-
03, AS-04, AS-05, AS-06, AS-07 and AS-08 Antenna Set.
Main information about the radiated emission and immunity testing are also
explained.
1.2 Documentation
Enclosed with this manual are:
•a service questionnaire to send back to NARDA if equipment service is
required.
•an accessories check list to verify all accessories enclosed in the
packaging.
1.3 Introduction to the
PMM Antenna Set
With a compact size, easy mounting set and polarization change, light
weight and broadband frequency range the Antenna Set series is the ideal
solution for automated measurements in the 30 MHz to 18 GHz frequency
range.
The PMM AS-02 covers from 30 MHz to 3 GHz, the AS-03/AS-04/AS-07
from 30 MHz to 6 GHz and the AS-05/AS-06/AS-08 from 30 MHz to 18
GHz. Common applications include measurements to EN 55022 emission
and CEI IEC 61000-4-3 immunity testing specifications.
The PMM AS-02 is composed of a PMM BC-01 Bi-Conical Dipole and
PMM LP-02 Log Periodic Dipole Array.
The PMM AS-03 and AS-06 include a PMM BC-01 Bi-Conical Dipole, PMM
LP-02 Log Periodic Dipole Array, PMM LP-03 Log Periodic Dipole Array
and PMM DR-01 Double Ridged Horn Antenna (for PMM AS-06 only).
The PMM AS-04 and AS-05 are composed of a PMM BC-01 Bi-Conical
Dipole, PMM LP-04 Log Periodic Dipole Array and PMM DR-01 Double
Ridged Horn Antenna (for PMM AS-05 only).
The PMM AS-07 and AS-08 include a BL-01 Bi-Conical Log Periodic
Dipole Array and PMM DR-01 Double Ridged Horn Antenna (for PMM AS-
08 only).
The supplied tripod PMM TR-01 is highly recommended; the tripod stand is
made by hard wood assuring the needed rigidity when holding the
antenna, the adjustable joint allows easy to mount and antenna
polarization change operations.
Document ASEN-81109 - NARDA 2018

1-2 General information
1.4 Standard
Accessories
The PMM Antenna Set are kits that include multiple units and standard
accessories; they are described in the following paragraphs.
1.4.1 PMM AS-02
(30 MHz – 3 GHz)
The PMM AS-02 Antenna Set includes the following standard accessories:
•BC-01 Bi-Conical Dipole Antenna
•LP-02 Log Periodic Dipole Array
•TR-01 Wooden tripod with extension and adjustable joint
•RF Cable/5 – RF cable (5m long)
•CC-01 Soft Carrying case
•Antennas Calibration Reports (one for each antenna unit)
•Return for Repair Form
•Operating Manual
Fig. 1-1 PMM AS-02 kit

General information 1-3
1.4.2 PMM AS-03
(30 MHz – 6 GHz)
The PMM AS-03 Antenna Set includes the following standard accessories:
•BC-01 Bi-Conical Dipole Antenna
•LP-02 Log Periodic Dipole Array
•LP-03 Log Periodic Dipole Array
•TR-01 Wooden tripod with extension and adjustable joint
•RF Cable/5 – RF cable (5m long)
•N(f)-N(f) adapter
•CC-01 Soft Carrying case
•CC-03 Soft Carrying case
•Support for LP-03
•Antennas Calibration Reports (one for each antenna unit)
•Return for Repair Form
•Operating Manual
Fig. 1-2 PMM AS-03 kit

1-4 General information
1.4.3 PMM AS-04
(30 MHz – 6 GHz)
The PMM AS-04 Antenna Set includes the following standard accessories:
•BC-01 Bi-Conical Dipole Antenna
•LP-04 Log Periodic Dipole Array
•CC-01 Soft Carrying case
•TR-01 Wooden tripod with extension and adjustable joint
•RF Cable/5 – RF cable (5m long)
•Antennas Calibration Reports (one for each antenna unit)
•Return for Repair Form
•Operating Manual
Fig. 1-3 PMM AS-04 kit

General information 1-5
1.4.4 PMM AS-05
(30 MHz – 18 GHz)
The PMM AS-05 Antenna Set includes the following standard accessories:
•BC-01 Bi-Conical Dipole Antenna
•LP-04 Log Periodic Dipole Array
•DR-01 Double Ridged Horn Antenna
•TR-01 Wooden tripod with extension and adjustable joint
•Antenna Support kit for DR-01
•CC-01 Soft Carrying case
•170/30N - Rigid Carrying case (for DR-01)
•RF Cable/5 – RF cable (5m long)
•Antennas Calibration Reports (one for each antenna unit)
•Return for Repair Form
•Operating Manual
Fig. 1-4 PMM AS-05 kit

1-6 General information
1.4.5 PMM AS-06
(30 MHz – 18 GHz)
The PMM AS-06 Antenna Set includes the following standard accessories:
•BC-01 Bi-Conical Dipole Antenna
•LP-02 Log Periodic Dipole Array
•LP-03 Log Periodic Dipole Array
•DR-01 Double Ridged Horn Antenna
•TR-01 Wooden tripod with extension and adjustable joint
•Support for LP-03
•Antenna Support kit for DR-01
•CC-01 Soft Carrying case
•CC-03 Soft Carrying case
•170/30N - Rigid Carrying case (for DR-01)
•RF Cable/5 – RF cable (5m long)
•N(f)-N(f) adapter
•Antennas Calibration Reports (one for each antenna unit)
•Return for Repair Form
•Operating Manual
Fig. 1-5 PMM AS-06 kit
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali NARDA Antenna
Manuali Antenna popolari di altre marche

Alfa Network
Alfa Network APA-L01 Manuale utente

Naval
Naval PR-422CA Manuale utente

Feig Electronic
Feig Electronic ID ISC.ANTH200/200 Series Manuale utente

TERK Technologies
TERK Technologies TV44 Manuale utente

Directive Systems & Engineering
Directive Systems & Engineering DSE2324LYRMK Manuale utente

HP