Neomitis RTE0A Manuale utente

WIRED DIGITAL ROOM
THERMOSTAT
Pack contains ............................................................................................1
Installaon ................................................................................................1
Installingbaeries.............................................................................................................1
Mounngofwallmoungplate .......................................................................................1
Wiring ...............................................................................................................................1
MounngoftheThermostat.............................................................................................2
Troubleshoong ........................................................................................2
Technical specicaons .............................................................................2
RTE0REA NEO ENG DH V05 18 08 2020
PACK CONTAINS
1
INSTALLATION
INSTRUCTIONS
The digital room thermostat is xed on the wall with the wall plate which is supplied
with the product.
MOUNTING OF WALL MOUTING PLATE
INSTALLATION
INSTALLING BATTERIES
3- Replace the baeries cover.
3- Secure the wall plate with the two
screws provided using the horizontal
and vercal holes.
TABLE OF CONTENTS
x2
AA Baeries (LR6)
x1
Thermostat
x2
Screw Anchor
x2
Screws
1- Remove the baeries cover which is
placed on the front of thermostat.
2- Insert the 2 baeries AA supplied.
Note the correct polarity according to
the engraving on the thermostat when
inserng the baeries.
1- Unscrew the 2 screws under the
thermostat.
2- Remove the wall plate from the ther-
mostat.
x2
WIRING
All wiring must be in accordance with IEE regulaons. This product is for xed wiring
only.
All electrical installaon work should be carried out by a suitably qualied
Electrician or other competent person. If you are not sure how to install
this thermostat consult either with a qualied electrician or heang En-
gineer. Do not remove or ret the appliance onto the backplate without
the mains supply to the system being isolated.
COM = Live
NC = Normally closed switch out (Sased)
NO = Normally open switch out (call for
heat)
RTE0A
Recommended locaons
for your thermostat.
To ensure that your ther-
mostat provides accurate
readings and controls eec-
vely, it must be installed
approximately 1.5 m above
oor level on an inside wall,
away from direct sunshine
and any other sources of heat
or cold such as radiators, cold
draughts, etc.
Important: The thermostat
measures the temperature of the place where it is installed. It does not take into
account the temperature dierences that may exist between dierent locaons in the
house if the temperature is not uniform.

NEOMITIS
®
LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contact_uk@neomis.com
Creang innovave soluons for ambient comfort
Registered trademarks - All rights reserved
2
www.neomitis.com
2- Secure the thermostat by screwing
the both locking screws under the
thermostat.
x2
Display disappears on thermostat.
- Check baeries.
- Replace the 2 baeries. Only use alkaline 1.5V AA (LR6) baeries.
Do not use rechargeable baeries.
The heang does not come on or does not go o.
- Your room thermostat may have been set up close to a source of heat or on a cold
wall – put it in a recommended locaon (see the “Installing” secon on page 1 for
these locaons).
- Check that the communicaon works between the thermostat and the boiler.
TROUBLESHOOTING
EU declaraon of conformity: We hereby declare under our sole res-
ponsibility that the products described in these instrucons comply with
the provisions of Direcves and harmonized standards listed below :
- LVD 2014/35/EU : EN60730-1 / EN60730-2-7/EN60730-2-9/ EN62311 ;
- EMC 2014/30/EU : EN60730-1 / EN60730-2-7/ EN60730-2-9 ;
- Direcve RoHS 2011/65/EU, amended by Direcves 2015/863/EU and 2017/2102/EU
: ROHS: EN50581:2012
Products are manufactured using processes that are cered ISO 9001: 2015
TECHNICAL SPECIFICATIONS
- Power supply: 2 alkaline 1.5 V AA (LR6) baeries.
- Baery life: approx. 2 years.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro disconnecon: Type 1B.
- Polluon degree: 2.
- Automac acon: 100,000 cycles.
- Class II.
Note: It is recommended to replace annually as part of the normal system service and
before leaving the property empty for a prolonged period.
Environment:
- Operaon temperature: 0°C to +40°C.
- Manual temperature seng range: from +5°C to +30°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensaon)
- Protecon rang: IP30.
Manufactured by: Neomis Ltd (contact_uk@neomis.com)
MOUNTING OF THE THERMOSTAT
1- Replace the thermostat on the wall
mounng plate.
The on the product indicates that you must dispose of it at the end of its useful
life at a special recycling point, in accordance with European Direcve WEEE 2012/19/
EU. If you are replacing it, you can also return it to the retailer from which you buy the
replacement equipment. Thus, it is not ordinary household waste. Recycling products
enables us to protect the environment and to use less natural resources.

Overview......................................................................................................... 1
Controls and display ........................................................................................ 1
Sengs ........................................................................................................... 1
Inialpowerup ................................................................................................................1
Operang ........................................................................................................ 1
Temperaturesseng ........................................................................................................1
Factorysengs .................................................................................................................1
Troubleshoong .............................................................................................. 2
Technical specicaons ................................................................................... 2
What is a room thermostat.............................................................................. 2
RTE0REa NEO ENG DH V05 18 08 2020
WIRED DIGITAL ROOM
THERMOSTAT
The desired temperature can be set.
TABLE OF CONTENTS
1
OPERATING
INSTRUCTIONS
RTE0A
Note: When the baeries must be changed, a low baery level indicator lights up on the
device.
Remember to take used baeries to baery collecon points so they can be recycled.
• LCD Display
Thank you for purchasing our RT0, digital room
thermostat.
It is by listening to your requirements we have
created and designed our products to be easy to
operate and install.
It is this ease of operaon that is intended to make
your life easier and help you save energy and money.
INITIAL POWER UP
SETTINGS
• Thermostat
C
C
Baeries
compartment
Rotary dial
Reset
buon
LCD display
C
C
Measured room
temperature
Pairing icon
(RF version)
Low baery
icon
Frost protecon
icon
Call for heat
icon
Temperature
setpoint
TEMPERATURES SETTING
OPERATING
1- To start: insert the two AA baeries
provided into the baery compart-
ment.
Once baeries are ed all symbols
will be displayed on the LCD screen as
shown for two seconds.
2- Aer 2 seconds, the LCD will show:
- The ambient temperature (°C) solid.
- The icon is solid when the heang
is turned ON.
- The setpoint temperature (°C) solid.
OK
Boost
Prog 1 2 3 GO
C
C
OK
Boost
Prog 1 2 3 GO
To set the temperature, turn the dial
clockwise, to increment the temperature,
turn the dial counter-clockwise, to decre-
ment the temperature.
The default temperature is 20°C (68°F).
C
C
OVERVIEW
CONTROLS AND DISPLAY
FACTORY SETTINGS
All LCD display will be turned ON for 2 seconds and the factory sengs will be res-
tored.
Note: To restore factory sengs, press and hold down this part for more than 3
seconds using the p of a pen.
C
C
Sengs Factory sengs
Set temperature 20°C

NEOMITIS
®
LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contact_uk@neomis.com
Creang innovave soluons for ambient comfort
Registered trademarks - All rights reserved
2
www.neomitis.com
The boiler is not heang:
- Check that the Thermostat is calling for heat if yes then the thermostat would appear
to be working check that the boiler has not switched itself o.
If no increase set temperature.
- Check the posion of the baeries. Remove them for 30 seconds and reinsert them. If
the problem persists, replace the 2 baeries.
Nothing in the display :
- Check the posion of the baeries. Remove them for 30 secondes and reinsert them.
If the problem persists, replace the 2 baeries.
The room temperature is not high enough, the boiler is not providing enough heat:
- Check the acve desired temperature and increase it if needed (see page 1).
You made a mistake while seng:
- You just need to restore factory sengs, as explained in the “Factory sengs” secon
(see page 1). This will reverse any changes you might have made.
The system is not heang but is on:
- If and indicator light is on but the system remains cold, then you should contact
your installer.
If the problem persists, then contact your installer.
Please refer to the installing instrucons for any informaons about baeries life, stan-
dards and product environment.
TROUBLESHOOTING
... an explanaon for householders
A room thermostat simply switches the
heang system on and o as necessary.
It works by sensing the air temperature,
switching on the heang when the air
temperature falls below the thermostat
seng, and switching it o once this set
temperature has been reached.
Turning a room thermostat to a higher set-
ng will not make the room heat up any
faster. How quickly the room heats up de-
pends on the design of the heang system,
for example, the size of boiler and radiators. Neither does the seng aect how quickly
the room cools down.
Turning a room thermostat to a lower seng will result in the room being controlled at
a lower temperature, and saves energy.
The heang system will not work if a me switch or programmer has switched it o. The
way to set and use your room thermostat is to nd the lowest temperature seng that
you are comfortable with, and then leave it alone to do its job. The best way to do this
is to set the room thermostat to a low temperature – say 18ºC – and then turn it up by
one degree each day unl you are comfortable with the temperature. You won’t have
to adjust the thermostat further. Any adjustment above this seng will waste energy
and cost you more money.
If your heang system is a boiler with radiators, there will usually be only one room
thermostat to control the whole house. But you can have dierent temperatures in indi-
vidual rooms by installing thermostac radiator valves (TRVs) on individual radiators. If
you don’t have TRVs, you should choose a temperature that is reasonable for the whole
house. If you do have TRVs, you can choose a slightly higher seng to make sure that
even the coldest room is comfortable, then prevent any overheang in other rooms by
adjusng the TRVs.
Room thermostats need a free ow of air to sense the temperature, so they must not
be covered by curtains or blocked by furniture. Nearby electric res, televisions, wall or
table lamps may prevent the thermostat from working properly.
WHAT IS A ROOM THERMOSTAT
TECHNICAL SPECIFICATIONS
Altri manuali Neomitis Termostato

Neomitis
Neomitis RT7 RF Manuale utente

Neomitis
Neomitis TMR7RFa Manuale utente

Neomitis
Neomitis RTE0B Manuale utente

Neomitis
Neomitis RTANEOA Manuale utente

Neomitis
Neomitis RTE7D Manuale utente

Neomitis
Neomitis RTE7D Manuale utente

Neomitis
Neomitis RTMA Manuale utente

Neomitis
Neomitis RTE7A Manuale utente

Neomitis
Neomitis RTE1RFD Manuale utente

Neomitis
Neomitis RT1 RF Manuale utente

Neomitis
Neomitis RT7 Manuale utente

Neomitis
Neomitis RT0 RF Manuale utente

Neomitis
Neomitis RTE7C Manuale utente

Neomitis
Neomitis RTEORFA Manuale utente

Neomitis
Neomitis TMR7 Manuale utente

Neomitis
Neomitis RTE7RFD Manuale utente

Neomitis
Neomitis RTE1D Manuale utente

Neomitis
Neomitis RTE0RFA Manuale utente

Neomitis
Neomitis RTE7SD Manuale utente