Nerival NEO-100 Manuale utente

2 www.nerival.fi
Table of contents
Safety instructions .....................................................................................................3
Overview....................................................................................................................4
Technical information ................................................................................................5
Installation example...................................................................................................6
Installation of mounting plate and door operator...................................................6
Outward opening door: Installation with push arm (door operator inside) ............7
Inward opening door: Installation with pull arm (door operator inside) .................8
Kytkentä.....................................................................................................................9
Button functions ......................................................................................................11
Settings ....................................................................................................................12
General settings 1-22............................................................................................12
Advanced settings................................................................................................. 13
Kauko-ohjaimen toiminnot ......................................................................................14
Adding a remote control.......................................................................................14
Deleting remote controls......................................................................................14
Digital display code table .........................................................................................15

3 www.nerival.fi
Safety instructions
This manual is intended for use by electrical professionals. All installation
connections and adjustments must be made in accordance with this instruction
manual.
•Before installation
Check for transport damages, do not install / use a damaged unit.
Make sure that the strength and stability of the wall and door structures are
sufficient.
•Connection
Only professional electricians are allowed to make electrical connections.
Make sure the power supply is turned off before making any connections.
This product must be earthed.
•Before turning on the power
Ensure correct supply voltage 230VAC.
Make sure that the input and output connections are connected correctly,
and the connectors are tight. Improper connection can damage the door
operator.
•Always switch off the power before installation or maintenance
and make sure that power is disconnected.
Read the manual carefully before installing the product.
Improper installation can be fatal.
The manufacturer or distributor is not responsible for the
consequences of incorrect installation or use.

5 www.nerival.fi
Technical information
Model
NEO-1000
Door max. weight
100kg
Door max. width
1200mm
Weight
6kg
Service life
More than 3.000.000 operations
Installation method
Surface mounting
Voltage output for locking
12VDC
With included relay card
12V AC/DC - 30V AC/DC
Door hold-open time
0-99s, adjustable
Opening angle
45°-180°, adjustable
Supply voltage
230VAC
Max. power
45W
Standby power consumption
< 2W
Remote control distance
Over 30m
Operating temperature
-40℃- 85℃
Protection class
IP41
Dimensions
580mm x 80mm x 90mm
Approvals
EU Directive
Test Standard(s)
2011/65/EU
(RoHs)
EN 62321-1:2013
EN 62321-2:2014
EN 62321-3-1:2014
EN 62321-4:2014+A1:2017
EN 62321-5:2014
EN 62321-6:2015
EN 62321-7-1:2015
EN 62321-7-2:2017
EN 62321-8:2017
EU Directive
Test Standard(s)
2014/30/EU
(EMC)
EN IEC 61000-6-1:2019
EN 61000-6-3:2007/A1:2011
/AC:2012

9 www.nerival.fi
Kytkentä
NO
NO, connected when the door is open
COM
COM
NC
NC, connected when the door is closed
L+
Electric lock output +12VDC*
L-
Electric lock output -12VDC*
GND
Voltage output -12VDC
12V
Voltage output +12VDC, max 500mA
P1+
Voltage signal 12VDC
GND
GND
P1
Door open signal
P2
Door close signal
P3
Closing door safety sensor input
P4
Opening door safety sensor input
GND
GND
P5
Synchronization of two door operators

10 www.nerival.fi
NO/COM/NC: Potential-free changeover switch.
P1 +: Door open signal from access control. The input is a voltage signal of 12VDC.
P1/GND: Door open signal. Sensor signal.
P2/GND: Door close signal. The door does not open when the signal is active.
P3/GND: Safety sensor for closing door. When the sensor detects, the door opens.
P4/GND: Safety sensor for opening door. When the sensor detects, the door stops.
P5/GND: Synchronization of two door operators. Both door operators operate
simultaneously.
* Use the included relay card if voltage used for locking is other than 12VDC.
Indice