4
5000 SERIES OPTIONAL EQUIPMENT ****************************************************************************
The following optional 5000 SERIES equipment
is available for use with the 8 zone Control
Panel. Securitel Interface Unit
Similar to the Telephone Auto Dialler but
Remote Intelligent Keypad provides higher security.
Remote or Intelligent Keypads can increase
convenience of operation and security of your Radio Control Equipment
system. A Radio Control Receiver can be connected to
the Panel to receive signals from Radio Trans-
Remote Keyswitch mitters such as hand-held panic/emergency
The Remote keyswitch will simplify the buttons.
operation of the Control Panel it is required. Real Time Event Recorder Printer
This device is connected to the Panel to
Satellite Siren RECORD and/or PRINT when any activity
Fitted with its own battery and electronics, a takes place.
Satellite Siren will operate independently of the
control panel if there is any interference to the Output Expander
system wiring. Provides 20 additional outputs for interfacing to
other equipment.
Telephone Auto Dialler
The Telephone Auto Dialler allows the 5000 Zone Expander
SERIES Control Panel to communicate alarms Provides an extra 16 Zones for the Panel.
via your telephone line.
Dialler Remote Control
This small hand-held device allows com-
munication and remote control between you at
a remote telephone and your Control Panel.
Securitel is a Trademark of Telecom Australia.
SPECIFICATIONS **********************************************************************************************
Construction 3mm Polycarbonate.
Dimensions (mm) 233 wide x 300 high x 85 deep.
Weight (with 6.5 AH battery) 3.3 kg.
Plug pack Input -240V AC. Output-17V AC. at 1.4A.
Power supply 13.8 V DC. at 1.25 Amps, current limited.
Quiescent Current Less than 80 mA.
Operating Voltage 10 V to 15V DC.
Rechargeable Battery 12 V, 6.5AH.
Battery Charge Current 450 mA maximum, current limited.
Dynamic Battery Test Every hour and when the Panel is Armed.
(whether mains power is on or off)
Dynamic Battery Test Low Voltage 10.7 V with a 5A load.
Fuses (5x20 mm) 4 x 1.5A, fast blow.
Zone Inputs End-of-line resistor = 2200 plus/minus 900 ohms
Remote Tamper Input Same as zone input.
Remote Keyswitch / Panic Button Input Same as zone input.
Remote Keypads' Inputs Proprietary.
Intelligent Keypad Outputs Proprietary.
Internal Siren Output Open collector, fused.
External Siren Output Open collector, fused.
Satellite Siren Output Proprietary.
Maximum number of Sirens 3 x 8 ohm Ohm speakers (not including Satellite
sirens since they have a separate siren driver circuit)
Latched Alarm (Strobe) Output 1.5 A at 12 V, open collector, fused.
Power Output for Optional Equipment With battery, 12 V, 1.5 A, fused.
Resetting Alarm Output 1.5 A at 12 V, open collector, fused.
24 hour Alarm Output 100 mA at 12 V, open collector, current limited.
Monitor Alarm Output 100 mA at 12 V, open collector, current limited.
Auxiliary Output 50 mA at 5 V emitter follower, current limited.