User Manual L400MD04C1A01
L400MD04C1A01
Mono channel costant current dimmer DALI/PUSH/POT/1-10V/BLE
Monochannel Dimmers with Output Current PWM.
Input Range: 8-53V DC.
Output Current PWM with current from 0.17A to 1.05A (54.6W at 52V DC).
Controllable with Android/iOS app Newlab Go.
In order to set the output current you will need the L392MA00N0A01
interface sold separately. Default current 0.35A.
In order to set the fade output and the logarithmic or linear output you will
need the L392MA00N0A01 interface sold separately, the other working
modes are automatically detected by the device. Please refer to user
manual.
Input Controls
Type Qty
Insulated Push button 1
DALI 1
Linear Potentiometer 100K 1
0-10V Passive 1
1-10V Passive 1
Bluetooth LE 1
TECHNICAL NOTES
- Monochannel Dimmers with Output Current PWM.
- Input Range: 8-53V DC.
- Power 7.35W @ 8V, 11.55W @ 12V, 24.15W @ 24V, 49.35W @ 48V,
54.6W @ 53V.
- The device is not equipped with earth connection
Protection against accidental contact is garantied by the enclosure.
- Power Connector Cross-section of conductors 14-30 AWG (0.05-2.08
mmq).
- Interface Connector Cross-section of conductors 15-30 AWG (0.05-1.65
mmq).
- Output Current PWM with current from 0.17A to 1.05A (54.6W at 52V
DC).
- Input Controls: Insulated Push button x1, DALI x1, Linear Potentiometer
100K x1, 0-10V Passive x1, 1-10V Passive x1, Bluetooth LE x1.
- Notice on 0-10V (1-10V): this control circuits is not insulated, use only
insulated 0-10V(1-10V) source generator.
- PWM Frequency: 390 Hz.
- Thermal foldback: 150 C. Degrees on uC.
- Storage Temperature Min: -40 Max: 60 C. Degrees.
- Working Temperature Min: -20 Max: 50 C. Degrees.
- Printed Circuit UL.
- Protection Class: IP20.
- Weight: 44 gr.
- Standard Dimension 40x80x24.45 mm.
- Dimension with accessories 40x100x24.45 mm.
- Reverse polarity protection.
- Open circuit protection.
- Surge voltage protection.
- Over temperature protection.
- Short circuit protection.
- In order to supply the device you have to use a SELV power supply in
order
to maintain the required elettrical security level
All connections must be made with non-live devices
and carried out by specialized personnel.
2 NEWLAB - User Manual L400MD04C1A01