Newman Rydal 5 SE Istruzioni di montaggio

Rydal 5 SE
Smoke exempt wood burning stove.
Installation & user instructions.
(To be left with customer).
Edition 2
Reference: NS-21
Date: 28TH October 2020

2
Contents
Pre-installation checks & general safety notes.
The Clean Air Act 1993 and Smoke Control Areas.
HETAS Ltd approval.
1.0 Technical and emission data.
2.0 Installation introduction
2.1 Unpacking the stove
2.2 Installing the stove
2.2.1 The tertiary air control
2.2.2 Assembling the baffle and removable internal stove parts
2.2.3 Stove data plate position
2.3 Stove placement / clearance requirements
2.4 The chimney
2.5 Stove pipe connection
2.6 Connecting to a masonry chimney
2.7 Connecting to a stainless-steel twin wall insulated flue system
2.8 Ventilation (Fresh air supply)
2.9 Chimney draft
2.92 Carbon monoxide alarm
2.95 Assembling the handle
2.96 Commissioning and handover
3.0 User Manual
3.1 Maximum fuel loads and choice of fuel
3.2 Use
3.2.1 Use with wood
3.2.2 Ash Removal
3.3 Maintenance
3.3.1 Replacing the glass panel to the stove door
3.3.2 Door seals
3.3.3 Cleaning and maintenance. (User)
3.3.4 Cleaning glass. (User)
3.3.5 Cleaning and checks inside the firebox. (User)
3.3.6 External surface cleaning. (User)
3.4 Operational problems – troubleshooting
3.5 Replacement parts
3.6 Product End-of Life / Recycling
3.7 Exploded view of stove parts and identification.
3.8 Declaration of Performance
3.9 Energy label
4.0 Product fiche

3
Pre-installation checks & general safety notes
Installation of this stove must be completed in accordance with current local codes and
regulations in each country. All local regulations & any rules in force, including those which
refer to national and European standards, must be observed when installing this product.
Reference must be made to current issues of British Standard BS 8303, code of practice for
installation of domestic heating and cooking appliances burning solid mineral fuel and BS EN
15287-1:2007 design, installation and commissioning of chimneys.
Note: It is a legal requirement under England & Wales Building Regulations that the
installation of this stove is undertaken under Local Authority Building Control or is installed
by a competent person registered with a Government Approved Competent Persons Scheme.
Hetas Ltd operate such a scheme and a listing of their registered Competent Persons can be
found on their website at www.hetas.co.uk
Should any conflict occur between these instructions and any regulations and rules in force
then the regulations and rules in force must apply.
An approved Carbon Monoxide alarm conforming to the latest edition of BS EN 50291 must
be installed into the room into which the stove is installed. Installation and positioning must be
in accordance with current National Building Regulations & any Rules in Force including
(Approved Document J. England & Wales). Also refer to the alarm manufacturer's
instructions.
This stove must not be installed into a flue that shares any other appliance.
Extractions fans or units must not be installed into the room of stove installation.
The installer has a responsibility to ensure that all requirements of Health & Safety at Work
Act are observed & implemented as stated on the date of installation.
Due to the weight of this stove adequate facilities must be available for loading, unloading &
installation.
Always ensure that there is an adequate air supply into the room containing the stove.
It is very important that flue ways are regularly swept & checked by an approved person. It is
recommended that sweeping and checking should be done at least twice each year for
approved smokeless fuel use and quarterly each year for wood burning. The installer must
ensure that the chimney is examined for soundness and suitability before the appliance is
installed. Remedial action should be taken if required, seeking expert advice if necessary.
Where the chimney is believed to have previously served an open fire installation it is possible
that the higher flue gas temperatures from a closed appliance may loosen deposits that were
previously firmly adhered, with the consequent risk of flue blockage. It is therefore
recommended that the chimney be swept a second time within a month of regular use after
installation.
All dampers or restrictors must be removed from the flue.
This stove must be maintained to ensure safe operation & efficiency.
Only use this appliance for domestic property heating in accordance with these instructions.
Fire cement can be caustic & should not be allowed to come into contact with skin. Refer to
manufacturer’s instructions.
This stove contains no asbestos. If there is any situation or possibility of disturbing any
asbestos during installation seek professional advice.
An installation / user manual is enclosed with this product. The installation can only be used
after it has been inspected by a qualified inspector. A name plate of heat-resistant material is
affixed to this product. This contains information about identification and documentation for

4
the product.
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the
authority to be a smoke control area. It is an offence to emit smoke from a chimney of a
building, from a furnace or from any fixed boiler if located in a designated smoke control area.
It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from the controls which generally
apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to
authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In
Scotland and Wales this power rests with Ministers in the devolved administrations for those
countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in
Northern Ireland. Therefore, it is a requirement that fuels burnt or obtained for use in smoke
control areas have been "authorised" in Regulations and that appliances used to burn solid fuel
in those areas (other than "authorized" fuels) have been exempted by an Order made and
signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here:
http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for details of
Clean Air Act requirements"
To ensure smokeless operation opertate the stove in accordance with these instructions. (Please
see instructions within this manual).
The Rydal 5 SE have been recommended as suitable for use in smoke control areas when
burning wood.
The appliance is only exempt when used in accordance with these instructions.
HETAS LTD approval
The Rydal 5 SE appliance has been approved by HETAS Ltd as intermittent operating
appliances for burning wood logs.

5
Technical data
1.0 Technical and emission data.
Rydal 5 SE
Material: Cast iron and steel.
Finish: High-temp resistant paint.
Fuel: Wood (Approved wood logs)
Log length: 25cm maximum
Flue outlet: Top or rear
Flue pipe dimension: Internal diameter 125mm / 122.7cm2 cross section
Approx. weight: 85kgs
Dimensions, distances etc: Figure 2 & 2A
Technical data according to EN 13240+A2:2004.
Nominal heat output: 4.9kw
Flue gas mass flow: 5.4 g/sec
Recommended chimney draught: 12.5 Pa
Efficiency: 80.9 %
CO emission (13% O2): 0.07%
Mean flue gas temperature at
ambient room temperature of 270C
at date of test: 217 0C
Operational mode: Intermittent
Emission data.
PM mg/m3 @ 13% 02: 6
OGC mg/m3 @ 13% 02: 57

6
CO mg/m3 @ 13% 02: 930
NoX mg/m3 @ 13% 02: 112
2.0 Installation introduction
2.1 Unpacking the stove
After removing the outer packaging, remove the combustion chamber from the wooden pallet and
place it gently on its back. The cardboard packaging can be placed underneath to prevent marring.
Remove the leg pack from the stove if not assembled at manufacture, bolt each leg securely to the
underside of the base on the combustion chamber, using the bolts provided (found inside the
stove). Note: There are lower bolts supplied for fitment into holes in the base of each leg, these are
adjustable to allow level adjustment of stove to uneven surfaces.
We recommend that two people perform the assembly and installation procedure.
2.2 Installing this stove
The stove and chimney installations MUST comply with all current National and Local Building
Regulations and any Rules in Force including current issues of British Standard BS 8303 code of
practice for installation of domestic heating and cooking appliances burning solid mineral fuel and
British Standards BS EN 15287-1:2007 design, installation and commissioning of chimneys; your
approved dealer or your local building control officer can advise regarding this. Ultimately, it is
you and your installer who is responsible to ensure that the installation complies with all relevant
regulations and any rules in force.
For installations within England and Wales also refer to Document J that gives guidance on
complying with the Building Regulations.
2.2.1 Tertiary air control.
The Tertiary air intake is a standard part for the Rydal 5 SE stove, there is no control to the tertiary
air intake as it is set at 100% open at manufacture.
2.2.2 Assembling the baffle and removeable internal parts.
See figures 1.1 to 1.10
All stove internal parts are assembled at manufacture, however with movements and handling
during stove delivery it is possible that some or all of the located parts inside the stove may have
moved, therefore it is important to check all these parts for correct position and fitment after the
stove is located. Check the baffle and all other parts are located into correct positions including
side cheeks, grate assemblies, banking bar and ash pan. Before lighting the stove for the first time,
confirm the baffle and all parts are in correct location.

7
Location of non-bolted stove internal parts.
Fig 1.1 Drawing of parts that are not bolt fixed to the inside of stove that may have
moved during transportation. These parts must be checked to ensure they are in
correct location before lighting the stove.
Fig 1.1

8
Figure 1.2 Top baffle positioning
Figure 1.3 Left hand stove vermiculite fire cheek positioning.

9
Fig 1.4 Lower vermiculite baffle positioning
Fig 1.5 Right hand stove vermiculite fire cheek positioning.

10
Fig 1.6 Showing top steel baffle in position & lower baffle positioning.
Fig 1.7 Stove main grate positioning