Newman PANTHER SE Istruzioni di montaggio

Smoke exempt WOOD burning stove
Installation & user instructions
(To be left with customer)
PANTHER SE
Reference: NS-20
Edition 2
Date: 14th February 2022

2
Index
Page. Section.
3 - 4 1.0 Pre-installation checks & general safety notes. Clean Air Act
1993 & smoke control areas. HETAS Ltd Approval
3 1.1 Pre-installation checks & general safety notes
3 - 4 1.2 The Clean Air Act 1993 and Smoke Control Areas
4 1.3 Hetas Ltd approval
5 2.0 Technical and emission data
6 - 26 3.0 Installation
6 3.1 Unpacking the stove
6 3.1.1 Installing the stove
6 - 12 3.1.2 Assembling the baffle and removable internal stove parts
12 - 13 3.2 Stove data plate position
14 - 16 3.3 Stove placement / clearance requirements
17 - 18 3.4 The chimney
18 - 19 3.4.1 Stove pipe connection
19 3.4.2 Connecting to a masonry chimney
20 3.4.3 Connecting to a stainless-steel twin wall insulated flue system
20 - 21 3.5 Ventilation (Fresh air supply)
21 3.6 Chimney draft
22 3.7 Carbon Monoxide Alarm
22 – 24 3.8 Handle
25 - 26 3.9 Commissioning and handover
27 - 54 4.0 User Manual
27 - 31 4.1 Warnings and Safety
32 - 33 4.2 Maximum fuel loads and Recommended fuel
33 - 36 4.3 General use & operation
36 - 37 4.3.1 Use with wood
37 - 40 4.3.2 Ash removal, disposal of ash & cleaning the main grate
40 - 45 4.4 Maintenance
40 – 41 4.4.1 Professional Safety & Service checks.
41 - 42 4.4.2 Replacing the glass panel & rope seal
43 4.4.3 Replacing the door rope seal
44 - 45 4.5 User cleaning and maintenance
44 4.5.1 User Maintenance Safety Warnings
44 4.5.2 Cleaning glass (User)
44 - 45 4.5.3 Cleaning and checks inside the firebox (User)
45 4.5.4 External surface cleaning (User)
46 - 51 4.6 Operational problems – troubleshooting
51 4.7 Replacement parts and modifications
51 4.8 Product End-of Life / Recycling
51 4.8.1 Consumable parts.
52 - 54 4.9 Exploded view of stove parts and identification
55 - 57 5.0 Declaration of Performance, Energy Label & Product Fiche
55 5.1 Declaration of Performance
56 5.2 Product fiche
57 5.3 Energy label

3
1.0 Pre-installation checks & general safety notes
Installation of this stove must be completed in accordance with current local codes and
Regulations in each country. All local Regulations & any Rules in Force, including those which
refer to National and European standards, must be observed when installing this product.
Reference must be made to current issues of British Standard BS 8303, code of practice for
installation of domestic heating and cooking appliances burning solid mineral fuel and BS EN
15287-1:2007 design, Installation, and Commissioning of chimneys.
Note: It is a legal requirement under England & Wales Building Regulations that the installation of
this stove is undertaken under Local Authority Building Control or is installed by a competent
person registered with a Government Approved Competent Persons Scheme. Hetas Ltd operate
such a scheme and a listing of their registered Competent Persons can be found on their website
at www.hetas.co.uk
Should any conflict occur between these instructions and any current Regulations and Rules in
Force then the Regulations and Rules in force must apply.
An approved Carbon Monoxide alarm conforming to the latest edition of BS EN 50291 must be
installed into the room into which the stove is installed. Installation and positioning must be in
accordance with current National Building Regulations & any Rules in Force including (Approved
Document J. England & Wales). Also refer to alarm manufacturer's instructions.
This stove must not be installed into a flue that shares any other appliance.
Extractions fans or units must not be installed into the room of stove installation.
The installer has a responsibility to ensure that all requirements of Health & Safety at Work Act
are observed & implemented as stated on the date of installation.
Due to the weight of this stove adequate facilities must be available for loading, unloading &
installation.
Always ensure that there is an adequate air supply into the room containing the stove.
It is very important that flue ways are regularly swept & checked by an approved person. It is
recommended that sweeping and checking should be done at least twice each year for approved
smokeless fuel use and quarterly each year for wood burning. The installer must ensure that the
chimney is examined for soundness and suitability before the appliance is installed. Remedial
action should be taken if required, seeking expert advice if necessary. Where the chimney is
believed to have previously served an open fire installation it is possible that the higher flue gas
temperatures from a closed appliance may loosen deposits that were previously firmly adhered,
with the consequent risk of flue blockage. It is therefore recommended that the chimney be
swept a second time within a month of regular use after installation.
All dampers or restrictors must be removed from the flue.
This stove must be maintained to ensure safe operation & efficiency.
Only use this appliance for domestic property heating in accordance with these instructions.
This appliance is not suitable and must not be installed to any type of water vessel.
Fire cement can be caustic & should not be allowed to come into contact with skin. Refer to
manufacturer’s instructions.
This stove contains no asbestos. If there is any situation or possibility of disturbing any asbestos
during installation seek professional advice.
An installation / user manual is enclosed with this product. The installation can only be used after
it has been inspected by a qualified inspector. A name plate of heat-resistant material is affixed to
this product. This contains information about identification and documentation for the product.
1.2 The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority
to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a
furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to

4
acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt"
appliance ("exempted" from the controls which generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise
smokeless fuels or exempt appliances for use in smoke control areas in England. In Scotland and
Wales this power rests with Ministers in the devolved administrations for those countries. Separate
legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore, it is a
requirement that fuels burnt or obtained for use in smoke control areas have been "authorised" in
Regulations and that appliances used to burn solid fuel in those areas (other than "authorized" fuels)
have been exempted by an Order made and signed by the Secretary of State or Minister in the
devolved administrations.
Further information on the requirements of the Clean Air Act can be found here:
http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and
supervision of smoke control areas and you can contact them for details of Clean Air Act
requirements."
To ensure smokeless operation opertate the stove in accordance with these instructions. (Please see
instructions within this manual).
The Panther 5 SE have been recommended as suitable for use in smoke control areas when burning
wood.
The appliance must be fitted with a mechanical stop to prevent closure of the secondary air controls
beyond 4mm open.
The appliance is only exempt when used in accordance with these instructions.
Operation with the air controls or appliance dampers open can cause excess smoke.
The appliance must not be operated with air control, appliance dampers or door left open except as
directed in the instructions.
1.3 HETAS LTD approval
The Panther SE appliance has been approved by HETAS Ltd as intermittent operating appliances for
burning wood logs.

5
2.0 Technical and Emission data
Material: Steel and Cast iron
Finish: High-temp resistant paint Fuel
Wood: Approved wood logs
Log length: 23cm x 8cm Diameter Maximum
Flue outlet: Top and rear
Flue pipe dimension: Internal 125mm / 113cm2 cross section
Approx. weight: 66kgs
Dimensions, distances etc.: Figure 2
Technical data according to EN 13240+A2:2004
Nominal heat output: 4.9kw
Flue gas mass flow: 5.0g/sec
Recommended chimney draft: 12 Pa
Efficiency: 78.7%
Co emission (13% O2): 0.10%
Flue gas temperature: 235o C
Operational mode: Intermittent
Emission data
Seasonal efficiency: 68.4%
Din Plus particulates: @ (13% 02), mg/Nm3 27
Mean CnHm emission: @ (13% 02), mg/Nm3 97
Mean CO emission: @ (13% 02), mg/Nm3 1209
Mean NOX emission: @ (13% 02), mg/Nm3 116
Energy Rating: A
Energy Index: 104

6
3.0 Installation
3.1 Unpacking the stove
After removing the outer packaging, remove the stove from the wooden pallet and place it gently on
its back. The cardboard packaging can be placed underneath to prevent marring. Remove the leg
pack from the stove if not assembled at manufacture, bolt each leg securely to the underside of the
base on the combustion chamber, using the bolts provided (found inside the stove). Note: There are
lower bolts supplied for fitment into holes in the base of each leg, these are adjustable to allow level
adjustment of stove to uneven surfaces.
Remove all parts and instruction and any combustible products from the stove including the energy
label affixed to the glass door. All instruction manuals and energy label to be given to the customer /
user. See commissioning and handover section 3.9
We recommend that two people perform the assembly and installation procedure.
3.1.1 Installing this stove
The stove and chimney installations MUST comply with all current National and Local Building
Regulations and any Rules in Force including current issues of British Standard BS 8303 code of
practice for installation of domestic heating and cooking appliances burning solid mineral fuel and
British Standards BS EN 15287-1:2007 design, installation, and commissioning of chimneys; your
approved dealer or your local building control officer can advise regarding this. Ultimately, it is you
and your installer who is responsible to ensure that the installation complies with all relevant
regulations and any rules in force.
3.1.2 Assembling the baffle and separate internal parts (see Figures 1.1 to 1.8)
All stove internal parts are assembled at manufacture, however with movements and handling
during stove delivery it is possible that some or all the located parts inside the stove may have
moved, therefore it is important to check all these parts for correct position and fitment after the
stove is located. Check the baffle and all other parts are located into correct positions including side
bricks, rear brick, grate assemblies, banking bar and ash pan. Before lighting the stove for the first
time, confirm the baffle and all parts are in correct location.
Location of non-bolted stove internal parts
Figure 1.1 Drawing of parts that are not bolt fixed to the inside of stove that may have moved during
transportation. These parts must be checked to ensure they are in correct location before lighting the
stove.

7
Figure 1.1

8
Figure 1.2 Top baffle positioning
Position the top baffle through the aperture into the firebox, ensure the 2 cut outs of the top baffle
are facing the front of stove and the angled lips are facing downwards. Position the top baffle into
position by feeding in an upward direction and locating the front angled edge with the 2 cut outs
onto the top of the top baffle support bracket, then lower the lower angled edge of the top baffle so
it locates into the left- and right-hand side support brackets.
Figure 1.2

9
Figure 1.3 Lower baffle positioning
Position the lower baffle through the firebox aperture; ensure the lower front lugs are to the front of
the stove. Feed the lower baffle in an upward direction and locate the front left and right-hand lugs
to each tab located to the left- and right-hand side of stove.
Lower the lower rear edge of the top baffle into correct position on top of the platform to the rear of
the stove above the tertiary air inlets.
Figure 1.3

10
Figure 1.4 Rear brick positioning
Position both rear fire bricks into correct position to the rear of the stove ensuring they are both
firmly against the internal rear wall of the stove ensuring not to leave a gap between each rear brick
where they meet.
Figure 1.4
Figure 1.5 Side brick positioning
Position the left- and right-hand side bricks through the aperture to the front of the stove and
position the top of each side brick behind each locating tab to the left- and right-hand side of the
lower baffle, lightly push the lower edges of each side brick so they both fit against the internal side
walls of stove. Figure 1.5