Recommended RAID set levels, number of RAID
sets, hot spares, and volume names are
preconfigured.
CClick the Apply button to apply the RAID settings
and then repeat for the second controller.
DClick the Next button to continue.
Step 7: Verifying configuration settings
In this step, review the summary of the settings you
have set up.
To change a configuration setting, click the step
identifier at the top of the System Configuration
wizard panel to go back to a specific step. For
example, if you want to change the Unity System
name, click the Step 2 icon.
To finalize the Unity Storage System setup, click
Create.
Step 8: Applying configuration settings
The System Configuration wizard begins applying
your settings, displaying the progress as the wizard
configures Unity.
When Unity System configuration is complete, you
can open the Add Storage Pool wizard, OR
Click No I’m finished to close the wizard.
Unity opens and displays the dashboard, where you
can view Cluster Status, Events, Storage System
statistics, Storage Pools, File Systems, and LUNs.
What’s next
Please see the Unity Setup Guide included with your
Unity System for setup instructions for:
Authentication
Adding a storage pool, file system and LUN
Mounting an iSCSI LUN on a Windows client
Mapping a CIFS file system to a Windows client
Safety notices
This equipment must be installed and operated in
compliance with local laws and regulations.
Ensure that the ambient temperature at the
installation site is between 5°C (41°F) and 30°C
(86°F). If the temperature at the site is not actively
regulated, ensure that daily and seasonal
temperature changes will not result in the ambient
temperature going outside these limits.
Always fully stabilize racks with wall anchors or
stabilizing legs, or both, before mounting the
Nexsan systems or any other components on the
rack.
Situate the rack so that full air flow at both the
front and the rear of the Nexsan systems is
possible.
Ensure that the floor beneath the mounting rack
has enough load-bearing capacity to support the
rack and all mounted components.
Always fully secure all rack-mounting hardware
when installing the Nexsan systems in a rack.
Insufficient rack-mount support may allow the
enclosure to fall onto other rack-mounted
hardware or onto the floor, potentially damaging
equipment or causing injury to nearby personnel.
Expansions.