MODULES ONTO FRAMES
Take the module out of its plastic bag.
Take the module key (red handle) out of the control box.
Insert the module into the frame insert the module key into the six module
keyholes on each module and turn counterclockwise until tight. There are
3 module keyholes approximately 1.5” from the top and 3 module keyholes
approximately 1.5” from the bottom.
Take out Module cable and wire according to the diagram found on the
website. Do this for all module cables. Make sure cables that are wired
between connected frames use the cable slot as seen in the diagram on the
right.
IMPORTANT: After every 12th module, per sign face, you must connect a
continuation cable from module 12 to module 13. You can find this cable in the
cord bag with the yellow tag entitled STAX Boost Power Continuation Cable.
IMPORTANT: The maximum amount on one 20A circuit is 24 modules.
IMPORTANT: 300 modules are the maximum number of modules per display.
1
2
OPEN MODULE BOX
CONFIGURE WIRING
P: 833.474.STAX
E:
TAXLED
NEXTLEDSIGNS.CO
WWW.STAXLED.CO
9