Nidac DT1 Manuale utente

DT1Series 2
SINGLE CHANNEL TALKING DIALLER
INSTALLATION MANUAL 2nd EDITION.

NEW FEATURES
•Simplified memory layout allowsfor quicker and easier programming.
•Phone line now uses RJ12 with standard connections.
NOW AVAILABLE
DRI24 -interface to allow the DT1to be used with 24V D.C. power supplies,
convenient for use with Fire Panels.
Note that the CH2, CH3, CH4 & CH5 inputs and the 2 relay outputs have no
function when the DRI24 is used with a DT1.
SPECIAL NOTE TO NEW ZEALAND CUSTOMERS
1. Alarm equipment or sensors etc. connected to the inputs shall meet the
requirements of the New Zealand Electricity Act 1993 and its associated codes
of practice.
2. The dialler shall only be powered by an approved power source.
3. The preferred method of dialling is to use DTMF tones as this is faster and more
reliable than pulse (decadic) dialling. If for some reason you must use decadic
dialling, the numbers must be entered using the following translation table as
this dialler does not implement the New Zealand “Reverse Dialling” standard.
Number to be dialled: 0 1 2 3 4 5 6 7 8 9
Number to program in dialler: 0 9 8 7 6 5 4 3 2 1
Note that where DTMF dialling is used, the numbers should be entered
normally.

DT1 Series 2 -SINGLE CHANNEL TALKING DIALLER
i
TABLE OF CONTENTS PAGE
PRODUCT FEATURES.........................................................................................1
DIALLER OPERATION .........................................................................................2
Power up...........................................................................................................2
Activation..........................................................................................................2
Call Sequence...................................................................................................2
Cancelling the Dialler ........................................................................................3
SPECIFICATIONS.................................................................................................3
INSTALLATION.....................................................................................................4
PROGRAMMING...................................................................................................6
Phone Numbers................................................................................................8
Dialling Mode....................................................................................................8
Message Repeat Time......................................................................................8
Maximum Dialling Attempts...............................................................................9
Key Switch Input Polarity...................................................................................9
Alarm Input Polarity...........................................................................................9
Alarm Input Mode..............................................................................................9
Slave / Latching Mode.....................................................................................10
Cut Off Message After DTMF ..........................................................................10
Shut Down Code.............................................................................................10
User Message.................................................................................................11
REPLAY OF PROGRAMMED DATA...................................................................11
Blank Memory Indication.................................................................................11
ERROR INDICATION..........................................................................................12
Program / Display Errors.................................................................................12
Operational Errors...........................................................................................12
LIST OF FIGURES PAGE
Figure 1: The DT1 with its outer cover removed.................................................4
Figure 2: Connecting an output that drives high to the DT1..............................5
Figure 3: Connecting an output that drives low to the DT1...............................5

DT1 Series 2 INSTALLATION MANUAL
1
PRODUCT FEATURES
•A-tick approved equipment.
•15 second user recordable voice message.
•1alarm input.
•Key Switch input to enable/disable the alarm input.
•Programmable polarity on alarm and key switch inputs.
•Non volatile memory stores programmed data and voice message for 10 years
without power.
•6 user programmable phone numbers.
•Up to 6 dialling attempts at communicating an alarm condition.
•Remote shutdown of dialler via user programmable shutdown code (1 to 7 digits)
on DTMF phones.
•Fully programmable through the on board keypad.
•Programmed information can be verified by replaying it on the 7-segment display
(numeric data) or through the on board speaker (recorded voice).
•50 millisecond debounce time on all inputs.
•Failure and Error code indication.

DT1 Series 2 INSTALLATION MANUAL
2
DIALLER OPERATION
POWER UP
When power is applied to the DT1 it will perform a self test, then flash the digit 1five
times on the 7 segment display. While the DT1 is performing the self test but before
the 1is displayed, the 7 segment display may show anything, this is normal.
ACTIVATION
The DT1 can be programmed to trigger from either a positive or negative going alarm
source. The key switch input can be used to cancel an alarm call and/or disable the
alarm input.
CALL SEQUENCE
Once the DT1 has been triggered, it will seize the phone line and hold it for 3 seconds
to clear any calls that may be in progress. It then waits a further 3 seconds to get a
line out before dialling a number. After dialling a phone number the DT1 plays the
user message. The DT1 repeats the user message for the programmed time and only
finishes the call at the end of a message repetition or until cancelled.
After receiving a trigger the DT1 will attempt up to 6 diallings to communicate the
alarm information (the maximum number of dial attempts can be set from 1 to 6, refer
to the MAXIMUM DIALLING ATTEMPTS section on page 9). Each programmed
phone number will be called in order until either the dialler has been shut down, or the
maximum number of dial attempts have been made. If there are less phone numbers
programmed than the max dial attempts, then the DT1 will redial the first number
followed by the second and so on, until the maximum number of dial attempts have
been made.
During the dialling of an alarm the DOT on the display will flash at a rate of twice per
second. If after dialling the maximum number of attempts the dialler has not been
cancelled, the DOT will remain on until the K/S (key switch) input state is changed
(dialler is changed between “Away/On” and “24 hour” mode) or the DT1 makes a
successful call after being triggered again. When the dialler is shutdown a “WARBLE”
sound indicating shutdown is heard over the phone line and the display dot will go off.
Should the DT1 be unable to attempt any calls because it has not been programmed
with enough information, it will display error number 5 (no phone numbers in memory)
on the seven segment display.

DT1 Series 2 INSTALLATION MANUAL
3
CANCELLING THE DIALLER
The dialler can be cancelled by one of three methods. These are, remote shutdown
over the phone line using the programmed shut down code, local cancel by the key
switch or by removing the alarm input (this last method will only work if the alarm input
has been selected to operate in the slaved mode). Once the dialler has been
cancelled it will not make any more calls until it receives another alarm trigger.
The remote shutdown of the dialler can be performed by anyone the dialler calls to
report an alarm. To cancel the dialler simply enter the programmed shut down code
(default = digit number 3) on a DTMF (tone) phone while the message is playing.
Note shutting down of the dialler does not shut down any local alarm, even if this is
the trigger source.
Note the dialler should be tested regularly to ensure that it is operating correctly.
SPECIFICATIONS
CONNECTIONS -4 screw terminals.
ALARM INPUT -User definable trigger polarity, can operate in latched or
slaved mode.
KEY SWITCH INPUT -User definable polarity. Application of the correct polarity
will enable the alarm input.
POWER SUPPLY -11.5 to 14V DC @ 150mA (max).
TELECOM LINE -Single RJ12socket (Western Jack). Supplied with lead
to suit a Telecom Mode 3 phone socket or TH3 adaptor.
COMMUNICATION
DIALLING FORMAT -Selectable as Decadic (pulse) or DTMF (tone).
USER MESSAGE -15 seconds for alarm and name and/or address.
MECHANICAL
DIMENSIONS -165mm width x 135mm depth x 45mm height.
WEIGHT -330 grams with cover (230 grams without).

DT1 Series 2 INSTALLATION MANUAL
4
INSTALLATION
All connections to the DT1 from an external alarm source are made via the row of
screw terminal connectors found on the circuit board. To gain access to the circuit
board, the outer cover will have to be removed. To do this, unscrew the two outer
screws on the under side of the DT1 (do not unscrew the centre screw) the cover will
now lift off.
To mount the DT1 the TEB dialler mounting bracket is available.
Figure 1: The DT1 with its outer cover removed.

DT1 Series 2 INSTALLATION MANUAL
5
There are 4 terminals on the DT1 board, of these 2 are power inputs, 1 is the key
switch input and 1 is the alarm input. The use of each terminal is described below.
+12 The positive input for the power supply (11.5 to 14V D.C.).
GND The negative (ground) input for the power supply.
K/S The key switch input. This input is driven in the same manner as the alarm
input below. When active, the key switch input puts the DT1 into “Away/On”
mode [the default setting requires +5 to 15V DC on K/S for “Away/On” mode].
CH1 This is the alarm input. The input is held low via an internal pull down resistor to
GND. The input can be put into its alarm state by either applying voltage to it or
removing voltage from it, depending upon the configuration of the input’s
polarity (for further information on input polarity refer to the ALARM INPUT
POLARITY section on page 10). To trigger the input from a source that only
drives low (eg. an Open Collector output or a normally open switch to GND) the
input will have to be pulled up to the positive voltage rail via a 10K resistor as
shown in Figure 3 below [the default setting requires +5 to 15V DC on CH1 to
trigger the dialler].
Figure 2: Connecting an output that drives high to the DT1.
Figure 3: Connecting an output that drives low to the DT1.

DT1 Series 2 INSTALLATION MANUAL
6
PROGRAMMING
All programming of the DT1 is done via the keypad on the unit with confirmation of
programmed data being given on the seven segment display as it is entered. The
internal speaker will give a short beep to indicate when a key has been pressed.
The user voice message is recorded by speaking into the microphone located on the
front of the unit. The message may be replayed through the on board speaker.
Programming of the DT1 is accomplished by first pressing the #key, a “P” will appear
on the display to indicate programming, next is a single or double digit entry identifying
the memory number, followed by a code of variable length depending on the memory.
Termination of programming is accomplished by pressing the #key, or by entering
the maximum number of digits for the memory number being programmed.
All key presses must be done within 10 seconds of each other or all information so
far programmed into the currently open memory will be lost. When this occurs the
speaker sounds a “BLARP” and an error 2 is displayed (refer to the ERROR
INDICATION section on page 12).
Programming of memories 70 to 9require the program link to be ON.
Note that the program link does not have to be removed for the dialler to operate.
The format for programming is
#<memory><code> #for memories 1 to 8.
or
#<memory><voice input> #for memory 9.

DT1 Series 2 INSTALLATION MANUAL
7
Where <memory> is one of the following numbers:
1First phone number (16 digits max)
2Second phone number (16 digits max)
3Third phone number (16 digits max)
4Fourth phone number (16 digits max)
5Fifth phone number (16 digits max)
6Sixth phone number (16 digits max)
70 Dialling mode (1 digit)
71 Message repeat time (3 digits)
72 Maximum dialling attempts (1 digit)
73 Key Switch polarity (1 digit)
74 Alarm input polarity (1 digit)
75 Alarm input mode (1 digit)
76 Slave / latching mode (1 digit)
77 Cut off message after DTMF (1 digit)
8Shutdown code (7 digits max)
9User message (voice data, 15 seconds)
When accessing any of the above <memories> for programming an “A” is displayed to
show that you have ACCESS to the memory location. After pressing the first digit of a
two digit memory ‘n’ will be displayed to indicate another digit is required. When all of
the code digits have been entered or a second #is pressed then a “WARBLE” sound
is heard and a “[” will be displayed for 1 second indicating that the memory is now
CLOSED.
<code> validity is dependent upon the <memory> being accessed and is described in
detail on the following pages.
Indice
Manuali Sistema di conferenza popolari di altre marche

Kramer
Kramer VIA GO Manuale utente

AVT
AVT MAGIC AC1 Go Manuale utente

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manuale utente

Sony
Sony PCS-I150 Manuale utente

Middle Atlantic Products
Middle Atlantic Products VTC Series Manuale utente

Prentke Romich Company
Prentke Romich Company Vanguard Plus Guida