Nipro TRUEresult mini Manuale utente

Owner’s Booklet
BLOOD GLUCOSE MONITORING SYSTEM
EASY TO USE
TINY SAMPLE SIZE
FAST RESULTS
NO
CODING
CODING
NO
CODING
NO
CODING

APPLY BLOOD SAMPLE
1 2
Two simple steps
INSERT TEST STRIP
Fast Test Guide
For quick reference only, not intended as
a substitute for complete instructions.
Please read entire Owner’s Booklet and
product Instructions for Use before testing.
Expected Results for people without diabetes:1
Plasma Blood Glucose Result
Before eating < 6.1 mmol/L
Two hours
after meals < 7.8 mmol/L
BLOOD GLUCOSE MONITORING SYSTEM

1
INTRODUCTION:
TRUEresult mini Blood Glucose Monitoring System
TRUEresult mini is a simple, accurate way to test whole
blood glucose (sugar) level, anytime, anywhere. Our goal
is to provide quality healthcare products and dedicated
customer service. For questions about TRUEresult mini
products, please see cover for phone number.
Please read complete Owner’s Booklet and
all product Instructions for Use.
IMPORTANCE OF BLOOD GLUCOSE MONITORING
e more you know about diabetes, the better you
will be able to care for yourself. A Doctor or Diabetes
Healthcare Professional will determine how oen you
should test and what your target ranges are for blood
glucose results. Having most results within your target
ranges show how well a treatment plan is working to
control glucose levels. Keeping results within your
target ranges helps slow or stop complications from
diabetes.
NEVER change your treatment plan without consulting
a Doctor or Diabetes Healthcare Professional.
Use of TRUEresult mini in a manner not specied in
this Owner’s Booklet is not recommended and may
aect ability to determine true blood glucose levels.
For
Assistance
Call
Use By
Date
For in vitro
Diagnostic
Testing Only
Lot
Number Authorised
Representative
SYMBOLS:
Keep
Dry
Caution
Single
Use
Only
Attention! Read
Instructions
for Use.
Sterile
Control
Storage
Temperature
Range
Manufactured
By
Serial
Number
Control
Level
Biological
Risk

2
FOR PATIENTS
IMPORTANT HEALTH and SAFETY
INFORMATION:
WARNING!
r
NEVER reuse Test Strips. NEVER wipe Test
Strips with water, alcohol or any cleaner. DO NOT
attempt to remove blood or Control Solution sample
from Test Strips or clean Test Strips and re-use.
Reuse of Test Strips will cause inaccurate results.
r NEVER add a second drop of sample to Strip.
Adding more sample gives an error message.
e TRUEresult mini Blood Glucose Monitoring
System is for one person use ONLY. DO NOT
share your Meter or your Lancing Device with
anyone, including family members. DO NOT use
on more than one person. ALL parts of your Blood
Glucose Monitoring System could carry blood-
borne pathogens aer use, even aer cleaning and
disinfection.
2,3
For cleaning and disinfecting your Meter, see
Meter Care, Cleaning/Disinfection. For cleaning
and disinfecting your Lancing Device see the
Instructions for Use.
We suggest cleaning the Meter when visibly
dirty. Wash your hands thoroughly with soap
and warm water aer handling the Meter,
Lancing Device, or Test Strips as contact with
blood presents an infection risk.

3
FOR PATIENTS
IMPORTANT HEALTH and SAFETY
INFORMATION:
If you have symptoms of low or high blood glucose,
check your blood glucose immediately. If your result
does not match the way you feel, repeat the test. If
your results still do not match the way you feel, call
your Doctor or Healthcare Professional.
r -PXCMPPEHMVDPTF)ZQPHMZDBFNJBTZNQUPNT
may be: - trembling, sweating, intense hunger,
nervousness, weakness, and trouble speaking.
r )JHICMPPEHMVDPTF)ZQFSHMZDBFNJBTZNQUPNT
may be: - intense thirst, a need to urinate oen, a
dry mouth, vomiting, and headache.

Other Important Information for Healthcare
Professionals:
e most accurate results come from using fresh, capillary
whole blood from the ngertip or forearm. Venous
whole blood collected into sodium or lithium heparin
vacutainer tubes may be used for testing by healthcare
professionals. Use of EDTA vacutainer tubes (purple top)
is not recommended and may cause low results. Mix tube
contents gently before using.
When comparing results between TRUEresult mini and
a laboratory system, perform a TRUEresult mini blood
test within 30 minutes of laboratory test. Diabetes experts
have suggested that glucose meters should agree within
0.83 mmol/L of a laboratory method when the glucose
concentration is less than 4.2 mmol/L, and within 20%
of a laboratory method when the glucose concentration is
4.2 mmol/L or higher.
4
If patient has recently eaten,
ngerstick results from TRUEresult mini can be up to
3.9 mmol/L higher than venous laboratory results.
5
DO NOT perform capillary blood glucose testing on
critically ill patients. Capillary blood glucose levels in
critically ill patients with reduced peripheral blood ow
may not reect the true physiological state. Reduced
peripheral blood ow may result from the following
conditions (for example):
6
r TIPDL
r TFWFSFIZQPUFOTJPO
r TFWFSFEFIZESBUJPO
r IZQFSHMZDBFNJBXJUIIZQFSPTNPMBSJUZ
with or without ketosis
4

5
IMPORTANT INFORMATION:
For the most accurate results using TRUEresult mini:
r Read all instructions before testing.
t TRUEresult mini is an in vitro (outside body) quantitative system
that is used for self-testing and point-of-care (bedside) testing of
human whole blood only.
t .FUFSEJTQMBZTSFTVMUTBTPlasma values.
t 6TFPOMZ536&SFTVMUTest Strips and TRUEresult Control
Solution with TRUEresult mini Meter.
t %POPUVTFGPSEJBHOPTJTPGEJBCFUFTPSGPSUFTUJOHCMPPEHMVDPTF
in newborns.
t 1FSGPSN$POUSPM5FTUTbefore performing a blood glucose test for
the rst time (see Getting Started).
r 8IFODBSSZJOHZPVS536&SFTVMUNJOJ4ZTUFNXJUIZPVEPOPU
leave it where the storage temperature printed on vial label may be
exceeded (car, boot, briefcase, etc).
Note: ree levels of TRUEresult Control Solution are available for
Quality Control Testing. Call for availability using the number
located on the cover of this Owner’s Booklet for information on
obtaining dierent levels of TRUEresult Control Solution.
t 3FNPWFPOMZPOF4USJQBUBUJNFGSPNWJBMXIFOUFTUJOH3FDBQ
vial immediately aer removing Strip.
t %POPUVTF536&SFTVMUNJOJ4ZTUFNEVSJOHBYZMPTFBCTPSQUJPO
test. is may falsely raise TRUEresult glucose results. Please
check with your Doctor before using TRUEresult mini.
7
t "TDPSCJDBDJEDPODFOUSBUJPOTBUPSBCPWFNNPM-NBZ
cause elevated meter glucose results.
7
r 536&SFTVMUNJOJ#MPPE(MVDPTF.POJUPSJOH4ZTUFNJTGPSPOF
person use ONLY. DO NOT share your Meter or your lancing
device with anyone, including family members. DO NOT use
on more than one person. ALL parts of your Blood Glucose
Monitoring System could carry blood-borne pathogens aer use,
even aer cleaning and disinfection.
2

6
Phone Number, Expected Results, Fast Test Guide....................
............................................................................................see covers
Introduction and Important Information.............................. 1-5
Table of Contents.......................................................................... 6
Know Your System
Meter........................................................................................ 7-9
Test Strip ..................................................................................10
Test Strip Vial Label ................................................................11
Control Solution Bottle Label.................................................12
Getting Started..........................................................................13
Quality Control Testing .................................................... 14-15
How to Test Control Solution.......................................... 16-18
Testing your Blood
Obtaining a Blood Sample................................................ 19-20
How to Test Blood Glucose.............................................. 21-22
System Out of Range Warning Messages.............................23
Time and Date Set-up........................................................ 24-25
Meter Memory
Viewing Averages.....................................................................26
Viewing Results ........................................................................27
$BSF$MFBOJOH%JTJOGFDUJPOBOE5SPVCMFTIPPUJOH
Caring for TRUEresult mini............................................. 28-29
Changing Battery................................................................ 30-31
Troubleshooting .......................................................................32
Display Messages............................................................ 33-34
Performance Characteristics................................................. 35-40
System Specications/Chemical Composition ........................41
System Safety Information..........................................................42
References......................................................................................43
Notes ..............................................................................................44

7
Know Your System
Meter
{“ V” Button
Increase numbers in Time/Date Set Up;
add ALT Symbol; move forward by date/time when
viewing results in Memory.
|“ O” Button
Turn Meter on to view Average values; to view
results in Memory and to access Time/Date Set Up.
}“ W” Button
Decrease numbers in Meter Set Up;
remove ALT Symbol; move backward by date/time
when viewing results in Memory.
~Display Screen
Shows results, messages, user prompts, information.
Test Port
Insert TRUEresult Test Strip here.
Strip Release Button
Press to release Strip aer testing.
Top
1
3
4
5
6
Bottom
Le Right

{Battery Tray
Gently pull to slide open Battery Tray.
Use one non-rechargeable 3V lithium battery
(#CR2032), positive (“+”) side up
(see Changing Battery).
|Meter Label
Contains Serial Number of Meter.
8
Back of Meter
1
Closed
Open
Indice
Altri manuali Nipro Misuratore di glicemia

Nipro
Nipro TrueResult Manuale utente

Nipro
Nipro TrueResult Manuale utente

Nipro
Nipro 4Sure Smart Duo Manuale utente

Nipro
Nipro TRUEtrack Manuale utente

Nipro
Nipro TrueResult Twist 2 Manuale utente

Nipro
Nipro TrueResult Manuale utente

Nipro
Nipro True2go Manuale utente

Nipro
Nipro TrueResult Manuale utente

Nipro
Nipro GlucoKey Connect TD-4183D/GD82a Manuale utente