Noritz CB199-DV Manuale utente

Owner's Guide
WARNING
CB199-DV / CB180-DV
Natural Gas(NG)/Liquid Propane Gas(LP)
–Donotstoreorusegasolineorotherinammablevaporsandliquidsinthevicinityofthisoranyother
appliance.
– WHAT TO DO IF YOU SMELL GAS
•Donottrytolightanyappliance.
•Donottouchanyelectricalswitch;donotuseanyphoneinyourbuilding.
•Immediatelycallyourgassupplierfromaneighbor’sphone.Followthegassupplier’sinstructions.
•Ifyoucannotreachyourgassupplier,calltheredepartment.
–Installationandservicemustbeperformedbyaqualiedinstaller,serviceagencyorthegassupplier.
Iftheinformationintheseinstructionsisnotfollowedexactly,areorexplosionmayresult,
causingpropertydamage,personalinjury,ordeath.
Models
CONDENSING GAS COMBI BOILER
ThankyouforpurchasingthisNoritzCondensingGasCombiBoiler.
Beforeusing,please:
Readthisguidecompletelyforoperationinstructions.
Completelylloutthewarrantyregistrationcard(includedseparately)andmailthedetachableportiontoNoritz
AmericaCorporation.Keepthisguide(andtheremainderofthewarrantyregistrationcard)where
itcanbefoundwhenevernecessary.
Installationmustconformwithlocalcodes,orintheabsenceoflocalcodes,theNationalFuelGasCode,ANSI
Z223.1/NFPA54-latesteditionand/or,NaturalGasandPropaneInstallationCode(CSAB149.1-latestedition).
Whererequiredbytheauthorityhavingjurisdiction,theinstallationmustconformtotheStandardforControls
andSafetyDevicesforAutomaticallyFiredBoilers,ANSI/ASMECSD-1.NoritzAmericareservestherightto
discontinue,orchangeatanytime,thedesignsand/orspecicationsofitsproductswithoutnotice.
Rev.11/15

2
Chapter 1 Product Overview Operation Flow Chart 3
Chapter 2 Safety Regulations Safety Precautions 4
Before Operation 7
During Operation 9
Important Safety Information 11
Chapter 3 Unit Operation Initial Operation 12
Control Panel Interface 13
Control Panel LCD Interface 14
How to use Control Panel
1.Clock Setting 15
2. Setting Domestic Hot Water Temperature(DHW) 17
3. DHW Preheat Activated Setting 18
4. DHW Preheat Timer Setting 19
5. Setting Heating Temperature 21
• User Mode 22
6. Lock Mode 23
7. Error History 23
8. Running History 24
9. Unit Setting 25
10. Preventing Damage from Freezing-1 26
11. Preventing Damage from Freezing-2 29
Chapter 4 Maintenance 1. General Maintenance 30
2. Cleaning the Combi Boiler 31
3. Flushing the Combi Boiler 33
4. Checking for Error Conditions 34
Chapter 5 Troubleshooting Troubleshooting 35
Chapter 6 Follow-up Service Follow-up Service 36
Memo 37
Owner’s Guide – Table of Contents

3
Operation Flow Chart
Heating Mode
Domestic Hot Water Mode (DHW Mode)
Operation Flow Chart
Chapter 1. – Product Overview
Burner
Air & Gas
Mixing
Burner
PlateHeat
Exchanger
Air & Gas
Mixing
PlateHeat
Exchanger
PrimaryHeat
Exchanger
SecondaryHeat
Exchanger
PrimaryHeat
Exchanger
SecondaryHeat
Exchanger
CirculationPump
Gas
Condensate
ColdWaterInlet
(DHW)
Hot Water Outlet
(DHW)
PressureReliefValve
(DHW)
PressureReliefValve
forHeating
CirculationPump
Gas
Condensate
AutoFeederValve
HeatingSupply Heating Return
AutoFeederValve
PressureReliefValve
forHeating
DHW Plate
Heat Exchanger
Burner
Air & Gas
Mixing
Burner
PlateHeat
Exchanger
Air & Gas
Mixing
PlateHeat
Exchanger
PrimaryHeat
Exchanger
SecondaryHeat
Exchanger
PrimaryHeat
Exchanger
SecondaryHeat
Exchanger
CirculationPump
Gas
Condensate
ColdWaterInlet
(DHW)
Hot Water Outlet
(DHW)
PressureReliefValve
(DHW)
PressureReliefValve
forHeating
CirculationPump
Gas
Condensate
AutoFeederValve
HeatingSupply Heating Return
AutoFeederValve
PressureReliefValve
forHeating
DHW Plate
Heat Exchanger
The Condensing Gas Combi Boiler discharges condensate.
When heat from the exhaust gas is collected within the secondary heat
exchanger, condensation occurs from moisture in the exhaust gas and
the resulting water is discharged from the drain pipe (approx. 2 gallons/
hour (7.5 liters/hour) maximum).
It is not a water leak. Do not plug or block the drain line as it must always
be allowed to freely ow.
Note: The condensate discharged is acidic with a pH level of
approximately 2-3. A condensate neutralizer may be required by local
code prior to disposal.
CondensatePipe
Condensate
comesoutfrom
here.

4
Safety Precautions
To avoid product damage, personal injury, or even possible
death, carefully read, understand, and follow all the instruc-
tions in the Installation Manual and Owner’s Guide and on the
Combi Boiler before installation, operation, or service.
Noritz cannot anticipate every circumstance that might in-
volve a potential hazard and our warnings are, therefore, not
all-inclusive. Proper installation, operation, and service are
your responsibility.
You must be satised that the operation and settings of the
Combi Boiler are safe for you and for others.
Safety Symbols are provided in the guide. When a user fails to
adhere to the following requirements, it can cause death, serious
damage, and a great property loss. For safety symbols, ‘DAN-
GER’ , ‘WARNING’ , CAUTION’ are indicated and the denitions
for these terms are below :
DANGER
Indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury. This signal word is limited to
the most extreme situations.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury. It is also used to alert
against unsafe practices and hazards involving only property
damage.
WARNING
FOR YOUR SAFETY READ
BEFORE OPERATING
If you do not follow these instructions exactly, a re
or explosion could result causing property damage,
personal injury or loss of life.
A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner. Do
not try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the oor because
some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don’t try to repair it, call a qualied service technician.
Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
WARNING
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be
performed.
3. Turn manual gas shutoff valve to ˝OFF˝ position
Safety Precautions
Chapter 2. – Safety Regulations

5
WARNING
Safety Precautions
Chapter 2. – Safety Regulations
OPERATING INSTRUCTIONS
1. STOP! Read the safety information on previous page.
2. Set the thermostat to lowest setting.
(Do not use Combi Boiler unless it is completely lled with
water.)
3. Turn OFF electrical power supply to the Combi Boiler.
4. This Combi Boiler is equipped with an ignition device
which automatically lights the main burner. Do not try to
light the burner by hand.
5. Turn gas shut-off valve clockwise to ˝OFF˝ position. Do not
force
6. Wait ve (5) minutes to clear out any gas. If you then smell
gas, STOP! Follow step ˝B˝ on previous page. If you don’t
smell gas, go to next step.
7. Turn manual gas shut-off valve to ˝ON˝ position.
8. Turn ON electrical power to the appliance.
9. Press and hold the ‘Temperature Setting Button’ for 5
seconds for Domestic Hot Water Temperature Setting.
10. Factory Default Domestic Hot Water Temperature
(120°F) is displayed. Set the desired Domestic Hot Water
Temperature.
11. Turn Domestic Hot Water faucet on.
12. Set thermostat to desired setting.
13. If the appliance will not operate, follow the instructions ˝To
Turn Off Gas To Appliance on previous page and call your
service technician or gas supplier.
Vapors from ammable liquids will explode and catch re
causing death or severe burns.
Do not use or store ammable products such as gasoline,
solvents or adhesives in the same room or area near the
appliance.
Keep ammable products :
Far away from Combi Boiler
In approved containers
Tightly closed
Out of children’s reach
Vapors
Cannot be seen
Vapors are heavier than air
Go a long way on the oor
Can be carried from other rooms to the main burner by air
currents
Do not install the appliance where ammable products will
be stored.
Read and follow Combi Boiler warnings and instructions.
If Owner’s Guide is missing contact the retailer or
manufacturer.
DANGER
Use this Combi Boiler at your own risk.
The outlet temperature of the Noritz Combi Boiler is fac-
tory preset to 120°F (49°C). The temperature can only be
changed by using the control panel.
Domestic Hot Water temperature over 125°F (52°C) can
cause severe burns instantly or death from scalding. Chil-
dren, disabled, and elderly are at the highest risk of being
scalded. Do not leave children or the infants unsupervised.
Check temperature of Domestic Hot Water before taking a
shower or bath. To control water temperature to a particular
faucet, temperature limiting valves can be installed by your
service professional.
DANGER
Safety Precautions

6
Safety Precautions
Chapter 2. – Safety Regulations
Proper care is your responsibility. Carefully read
and understand the Operating Information in this
guide before operating the Noritz Combi Boiler.
Befullyawareofwherethegasshut-ovalveis
located and how to operate it.
Close the gas shut-o valve immediately if the
applianceissubjectedtore,overheating,ood,
physicaldamage,oranyotherdamagingcondition
thatmightaecttheoperationoftheunit.
TheCombiBoilermustbecheckedbyaqualied
technician before resuming operation.
DO NOT use this Combi Boiler if any part has
been under water, call a qualied technician
immediately for inspecting the Combi Boiler and
for replacing any part of the control system and
any gas control which has been under water.
Do not power up the unit unless the gas and water
supplyvalvesarefullyopened.Makesurethatfresh
airintakeueandexhaustgasueareopenedand
functional.
DO NOT attempt to install, repair, or service the
Combi Boiler by yourself.
Contact a qualied technician if the Combi Boiler
needs repair or maintenance.
Askyourgassupplierforalistofqualiedservice
providers.
˝Verifyproperoperationafterservicingoperation˝
The gas ignition system components must be
protectedfromwater(dripping,spraying,rain,etc.)
during appliance operation and service (circulator
replacement,condensatetrap,controlreplacement,
etc.)
PRODUCTS TO AVOID AREAS LIKELY TO HAVE CONTAMINANTS
Spray cans containing uorocarbons Dry cleaning/laundry areas and establishments
Permanent wave solutions Swimming pools
Chlorinated waxes/cleaners Metal fabrication plants
Chlorine-based swimming pool chemicals Beauty shops
Calcium chloride used for thawing Refrigeration repair shops
Sodium chloride used for water softening Photo processing plants
Refrigerant leaks Auto body shops
Paint or varnish removers Plastic manufacturing plants
Hydrochloric or Muriatic acid Furniture renishing areas and establishments
Cements and glues New building construction
Antistatic fabric softeners used in clothes dryers Remodeling areas
Chlorine-type bleaches, laundry detergents, and cleaning solvents Garages and workshops
Do not operate the Combi Boiler if its combustion air intake is located in or near one of the areas or in the vicinity of products listed in
Table. These areas will always contain hazardous contaminates that can form strong acids while passing through the burner and vent
system. These acids will corrode the Combi Boiler’s heat exchanger, burner components and vent system, resulting in ue gas spillage
and/or water leakage, possible substantial property damage, severe personal injury, or death. If the Combi Boiler combustion air intake
is located in any area likely to cause or contain contamination, or if products which would contaminate the air cannot be removed, the
intake must be re-piped and terminated to another location.
WARNING
DANGER
Safety Precautions

7
Before Operation
Chapter 2. – Safety Regulations
CAUTION
1. Check the gas being used.
When the Combi Boiler is used or moved for the rst time, user
must check whether the type of gas being supplied matches the
specic gas type for the appliance.
The type of gas is indicated on the rating plate on side of the
Combi Boiler.
3. Check the gas valve.
Please conrm the gas valve connected to the Combi Boiler.
(It must be closed during installation)
4. Check the water valve.
Please leave the appliance water supply valve open at all times
(it must be closed during installation)
Before Operation
2. Check the electricity being supplied.
Please check whether the appliance is connected properly.
120VAC / 60Hz
Open
Close
Open

8
Before Operation
Chapter 2. – Safety Regulations
WARNING
Do not store ammable material in the appliance
room.
Do not store portable gas container, thinner, oil, or other
ammable materials in the room. Otherwise, re may break out.
Do not place combustible items, such as newspapers
or laundry, near the appliance or venting pipe.
Do not store combustible (ammable) materials such as papers.
Do not hang clothes on the exhaust vent. Otherwise, re may
break out.
CAUTION
Pull out the power plug from the receptacle if light-
ning strikes.
Lightning can damage the Combi Boiler. Pull out power cord
plug if lightning strikes for your safety.
Before Operation
Burn Protection
Be cautious when opening the Domestic Hot Water tap.
The water may be very hot. Especially, children, disable and
elderly are at the highest risk of being scalded.
(Freeze protection is unavailable if the unit is unplugged from
power.)

9

10
Do not disassemble the Combi Boiler.
Service must be performed by a qualied installer, service
agency and gas supplier. Otherwise, Warranty will be voided.
Burn Protection
Do not touch the exhaust vent, DHW Outlet, Heating Supply
and Heating Return pipes during operation since they are very
hot. Otherwise, the user may get burned.
Do not shut off the Combi Boiler.
When you leave home for a long time, do not shut off the Combi
Boiler. The Combi Boiler has a freeze protection function.
The freeze protection feature will not work if electrical power,
gas, or water is disconnected.
Do not wipe the appliance or control panel with wet
cloth.
Otherwise, electric shock may occur, or internal parts may be
deteriorated or failed due to the inltration of moisture.
During Operation
Chapter 2. – Safety Regulations
CAUTION
During Operation
Altri manuali per CB199-DV
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Noritz Caldaia

Noritz
Noritz NH-2001-DV Guida rapida

Noritz
Noritz NRCB180DV Manuale utente

Noritz
Noritz CB199-DV Manuale utente

Noritz
Noritz NH199-DV Guida

Noritz
Noritz NRCB199DV Manuale utente

Noritz
Noritz NH-2001- DV Manuale utente

Noritz
Noritz NRCB199DV Manuale utente

Noritz
Noritz NH199-DV Guida rapida

Noritz
Noritz N-069M-DV-CA Manuale di istruzioni