Novita NAC12000 Istruzioni operative

3-IN-1 PORTABLE
AIR CONDITIONER
NAC12000/
NAC14000
Please read instructions before using
the 3-In-1 portable air conditioner
OPERATING
INSTRUCTIONS
AND E-WARRANTY
APPLICATION

PRODUCT DESCRIPTION
CONTROL PANEL DESCRIPTION
REMOTE CONTROL DESCRIPTION
TECHNICAL SPECIFICATIONS
USING THE NOVITA 3-IN-1 PORTABLE AIR CONDITIONER
• Setting Up
• Operating Notes
• Assemble/Replace Remote Control Batteries
• Using the Remote Control
• Water Condensation Drainage Method
• Filter Replacement
CLEANING & MAINTENANCE
• Cleaning & Maintenance of the Portable Air Conditioner
• Cleaning & Maintenance of the Pre-Filter Screens
TROUBLESHOOTING
ERROR CODE TROUBLESHOOTING
SAFETY PRECAUTIONS
SAFETY INSTRUCTIONS
GROUNDING METHOD
NOVITA CUSTOMER SERVICE GUARANTEE
E-WARRANTY APPLICATION
LIMITED WARRANTY TERMS & CONDITIONS
PRODUCT WARRANTY – UPGRADE/CONVERT TO ONSITE WARRANTY
PRODUCT WARRANTY EXTENSION – EXTENDED CARRY-IN WARRANTY
02
03
04
05
06
14
16
17
18
19
19
20
20
21
22
23
CONTENTS
This product includes:
• novita 3-In-1 Portable Air Conditioner NAC12000/NAC14000
• 1 x Hose Inlet, Exhaust Hose (1.5 Metre) and Hose Outlet
• 1 x Window Slider Kit
• 1 x Remote Control with Battery
• 1 x PVC Drainage Hose (1 Metre)
• novita Portable Air Conditioner NAC12000/NAC14000 Operating Instructions & e-Warranty
Application (e-Copy)
• Starter Guide
* Please contact us immediately if any of the above-mentioned items are not included.

PRODUCT DESCRIPTION
FRONT VIEW BACK VIEW
02
PRODUCT ACCESSORIES
01. Control Panel
02. Handle (Both Sides)
03. Easy Roll Castors
04. Air Outlet Flap
05. Remote Control Receiver
06. Upper Air Inlet Grille
07. Exhaust Hose Connector
08. Plug Fixer
09. Continuous Drainage
10. Power Cord & Plug
11. Middle Drainage
12. Lower Air Inlet Grille
1 Set of Hose Inlet Connector,
Exhaust Hose (1.5 Metre) and
Hose Outlet Connector
1 Set of Window Slider Kit
1 Set of Remote Control
with Battery
1 Set of PVC Drainage Hose
(1 Metre)
04
01
02
03
05
52 cm
52 cm
1x
3x
11
12
06
07
08
10
09

CONTROL PANEL DESCRIPTION
03
Timer Control
Fan Speed Control
Decrease Temp. Setting Control
Increase Temp. Setting Control
Prog. Mode (Cool, Dry, Fan or Smart Mode)
Power Control
Timer Indicator
Fan Speed Indicator (High, Medium, Low or Auto)
Display Screen
Operating Mode Indicator
Sleep Mode Indicator
01
02
03
04
05
06
07
08
09
10
11
01 02 03 04 05 06
0807 09 10 11

REMOTE CONTROL DESCRIPTION
04
Cool Indicator
Dry Indicator
Fan Indicator
Heat Indicator (Not Applicable for
This Model)
Smart Mode
Temperature Display Unit
Childlock Indicator (To Lock
Remote Control)
Turbo Mode
Sleep Mode Indicator
Timer to Auto Turn Off Indicator
Timer to Auto Turn On Indicator
Air Outlet Flap Oscillation Indicator
Fan Speed Setting Indicator
Power Control (On/Off)
Increase Temp./Timer Setting Control
Timer Control
Decrease Temp./Timer Setting Control
Sleep Mode
Fan Speed
Temperature Display Unit (oC/oF)
Oscillation
Prog. Mode (Cool, Dry, Fan or Smart Mode)
Turbo Mode Indicator
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
REMOTE CONTROL DISPLAY SCREEN
REMOTE CONTROL BUTTON
01
12
11
18
17
16
14
15
10
19
09
07
08
23
22
21
20
06
13
02 03 04 05
• When this mode is selected, unit
will operate under fan mode.

Model
Rated Power
Rated Current
Net Weight
Dimension (W x D x H)
Voltage/Frequency
Cooling Capacity
Cooling Input Power
Cooling Current
Airflow Volume
Recommended Cooling
CoverageArea¤
Recommended Dehumidifying
CoverageArea¤
Extraction Capacity
(30oC/85%RH)
Noise (Sound Pressure)
Refrigerant/Charge
Ingress Protection
Suction Pressure
Discharge Pressure
Max Allowable Pressure
Product Accessory
NAC12000
1400 Watts
6.8 A
32.7 Kg
450 x 396 x 745 mm
220-240V~/50Hz
12,000 BTU
1180 Watts
5.2 A
450 m3/hr
Up to 25 m2or 269 ft2
Up to 65 m2or 700 ft2
2.5 Litres/Hr
49 dB(A)
R410A/0.53 Kg
IPX0
2.1 MPa
4.2 MPa
7.0 MPa
• 1 Set of Hose Inlet, Exhaust Hose (1.5 metre) and Hose Outlet
• 1 Set of Window Slider Kit
• 1 Set of Remote Control with Battery
• 1 Set of Drainage Hose (1 metre)
NAC14000
1560 Watts
7.9 A
33.3 Kg
450 x 396 x 745 mm
220-240V~/50Hz
14,000 BTU
1380 Watts
6.2 A
410 m3/hr
Up to 27 m2or 290 ft2
Up to 90 m2or 967 ft2
3.4 Litres/Hr
51 dB(A)
R410A/0.58 Kg
IPX0
2.1 MPa
4.2 MPa
7.0 MPa
05
¤ It is recommended to confine to the stated recommended coverage area for unit’s optimum performance.
TECHNICAL SPECIFICATIONS

Setting Up
USING THE NOVITA 3-IN-1 PORTABLE AIR CONDITIONER
EXHAUST HOSE INSTALLATION
The 3-In-1 portable air conditioner must be placed proximity to a window or opening to channel out the
warm exhaust air when operating under cool or dry mode.
• The hole on the window slider is intended for the hose outlet connector.
• Position the unit on a flat and level surface and ensure there is a clearance space of at least 45 cm around the
unit, and proximity to the power supply.
• This product purchase is not inclusive of installation service. For installation please engage the distributors
installation contractors to arrange for appointment and quotation directly.
• To remove exhaust hose, exert some pressure to depress the
release catch and slide up the exhaust hose.
06
Connect the exhaust hose to the hose connector at the back of
the unit. Slide in the hose connector downwards until it is locked
in place.
Affix the hose outlet to the window slider. Ensure that all the
connections are tight and installed properly. Then connector the
window slider to the window.
WINDOW SLIDER KIT INSTALLATION
TRIMMING OF WINDOW SLIDER
The window slider kit is designed to fit most standard vertical and
horizontal window application. While if the window opening is shorter
than the minimum length of the window slider kit, user may cut the
opposite end from the hole to fit into the window opening.
• DO NOT cut from the side of the window slider with hole.
Extend one side of the exhaust hose, then rotate to
screw in the hose inlet connector. Install and rotate the
hose outlet connector over the opposite end of the
exhaust hose. Ensure secure fit on both ends.
03
Vertical
Window
Window Slider
Window Slider
Horizontal
Window
02
Slide Into
To Install
Exhaust Hose
To Remove
Exhaust Hose
1
2
1
2
Slide Up
Exhaust Hose
Release Catch
01
Extend Hose
Hose Outlet Connector
Assembled
Hose Inlet Connector
01
Cut on Opposite
Side of Hole

• The unit should be placed on a dry, flat and level surface to minimize noise and vibration.
• The unit is equipped with easy roll castors to facilitate manoeuvring the unit on smooth and
flat surfaces. Please exercise caution when rolling it on carpeted surfaces and wooden flooring.
07
LOCATING THE UNIT
Allow a clearance space of at least 45 cm away from the wall for
unit’s optimum performance. To ensure optimal efficiency of the
unit, keep doors and windows closed when using the cool and dry
mode. When using the fan mode, an open window could help to
improve air circulation.
01
The exhaust hose can be extended, but it is recommended to keep the
length of the exhaust hose as short as possible.
02
3-PIECE WINDOW SLIDER
Slide panel B and C into panel A and size it to the window opening width.
When sizing the window width, ensure the window slider assembly is
free from gaps or any air pockets for accurate installation and fitment.
Fasten the screws into the corresponding holes. Check to ensure all
connections are tight and installed properly.
4-PIECE WINDOW SLIDER
Slide panel B and C into panel A and size it to the window opening width.
When sizing the window width, ensure the window slider assembly is
free from gaps or any air pockets for accurate installation and fitment.
Fasten the screws into the corresponding holes. Check to ensure all
connections are tight and installed properly.
• DO NOT attempt to roll the unit over objects.
• The unit must be placed in proximity to a properly rated grounded socket.
• DO NOT place any obstacles around the air inlet or air outlet.
• Always ensure the exhaust hose path is not blocked or obstructed to
maintain a smooth flow and operation.
• DO NOT replace, lengthen or install the exhaust hose onto the unit via
other methods, as this could result the unit to malfunction.
2-PIECE WINDOW SLIDER
Slide Panel B into Panel A and size it to the window opening width. When
sizing the window width, ensure the window slider assembly is free from
gaps or any air pockets for accurate installation and fitment. Fasten the
screws into the corresponding holes. Check to ensure all connections are
tight and installed properly.
45cm
45cm
45cm
Not Recommended
02
A
B
D
B
D
A
03
AB
C
D
CAB
D
04
A
A
B
C
D
D
D
C
A
AB
D

08
ELECTRICAL CONNECTIONS
Before plugging the unit into the power supply, please check that:
•The main power supply corresponds to the specifications indicated on the product label at the back of the unit.
• The power source and electrical circuit are adequate for the appliance.
• Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
• Failure to follow these important safety instructions would void the limited warranty.
For optimum unit’s performance, it is recommended to:
• Close the windows and doors in the room to be air conditioned.
• Draw the curtains/blinds to avoid direct exposure to sunlight/heat.
• Never put any objects on the unit.
• DO NOT block/obstruct the air inlet and air outlet.
• Ensure there is no heat source in the room when the unit is operating.
• DO NOT use the unit in high very damp room/environment.
• DO NOT use the unit for outdoor environment.
• Ensure the unit is placed on a flat, stable and levelled surface.
• Before installing the unit, place it upright for 6 hours before use to allow the refrigerant to stabilize.
Operating Notes
Standby Mode
02. Cool Mode
Press the button consecutively to select . Press the or button to select the preferred
temperature from 18oC to 32oC and desired fan speed (High, Medium, Low or Auto) by pressing the
button.
Under Cool Mode, unit is programmed to work in accordance to the temperature difference between the
surrounding and desired temperature setting when auto fan speed is selected.
01. Power On/Off
• Air outlet flap automatically opens when the unit is turned on, and automatically closes when the unit is turned off.
• User may adjust the air outlet flap position by using the remote control oscillation function.
• Unit is programmed to operate based on the last preceding setting.
• Press the button once again to turn off the unit. Always wait for a few minutes before removing the power
plug from the power supply. This is to allow the unit to perform a cycle of checks to verify operation.
Connect power plug to the power supply. The display screen illuminates with , indicating the unit is
on standby mode, ready to be switched on anytime. Press the button to turn on/off the unit.
... ...
• DO NOT force open or close the air outlet oscillating flap to prevent damage to the oscillation mechanism.
Turn On
Surrounding
Temperature >Desired
Temperature Setting
Cool Mode
High
Medium
TEMPERATURE DIFFERENCE OPERATING MODE
Temp. Difference
of ≥2oC
Surrounding
Temperature ≤Desired
Temperature Setting
Fan Mode
Low fan speed mode and runs
in an operation cycle of
3 mins on/17 mins off.
Temp. Difference
between 0oC to 1oC
FAN SPEED SETTING

09
• Ensure the exhaust hose is installed properly before operating Cool Mode.
• The fan speed setting difference is more obvious under Fan Mode than Cool Mode.
• Auto fan speed setting is only available under cool mode, dry mode and smart mode only.
• Under Fan Mode, the exhaust hose does not need to be installed to the unit.
• Auto Mode is unavailable at Fan Mode.
Unit Display Screen
High Medium Low
03. Fan Mode
Press the button consecutively to select . Select the preferred fan speed (High, Medium or Low) by
pressing the button and its corresponding indicators will be shown on the display screen.User may
also press the button on the remote control as shortcut key to access the fan mode at high fan speed
setting.
04. Dry Mode
Unit Display Screen
Before activating Dry Mode, please ensure the exhaust hose is properly installed onto the unit. Press the
button consecutively to select and the display screen will show . Under Dry Mode, temperature
and fan speed setting are automatically programmed and cannot be adjusted.
Remote Control
Display Screen
Dry
Mode
Remote Control Display Screen
High Medium Low
Fan
Indicator
Fan Speed
Setting Indicator
User may also press the button on the remote control as shortcut key to access 18oC and high fan
speed setting.
User may also press the button on the remote control as shortcut key to access the fan mode at high
fan speed setting. Adjust the fan speed setting between High, Medium or Low by pressing the button.
• When room temperature is less than 16oC, Dry Mode is unavailable and the compressor will stop operating, only
the fan motor will continue to run.
• The button on the remote control is non-functional under dry mode.
Unit Display Screen Remote Control
Display Screen
Cool
Mode
Press button to select
cool mode, adjust temp
with or button,
then press button to
select fan speed.
Press button to select
fan mode, adjust speed
with button.
Press button to select
dry mode.
Questo manuale è adatto per i seguenti modelli
1
Indice