nvent SCHROFF 24579-415 Manuale utente

CPCI Serial System 3+1 U
User’s Manual
Product No.:
24579-415
July 20, 2011
Doc-No: 63972-307_R1.0

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright2011
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 July 20, 2011 Initial Release

CPCI Serial System 3+1 U
24579-415
www.schroff.biz 1 R1.0, July 20, 2011
1 Safety................................................................................................................. 1
1.1 Intended Application............................................................................................ 1
1.2 Safety Instructions............................................................................................... 2
1.2.1 Safety Symbols used in this document.................................................. 2
1.3 General Safety Precautions................................................................................. 2
2 Product Definition............................................................................................. 3
2.1 References and Architecture Specifications........................................................ 3
2.2 System Overview................................................................................................. 4
2.3 Subrack................................................................................................................ 4
2.4 CPCI Serial Backplane........................................................................................ 5
2.4.1 Backplane topology ............................................................................... 6
2.5 Power Supply....................................................................................................... 7
2.5.1 ATX Power Supply................................................................................. 7
2.5.2 Load Resistor......................................................................................... 8
2.5.3 Grounding/Earthing................................................................................ 8
2.6 Cooling................................................................................................................. 9
3 Installation....................................................................................................... 10
3.1 General Installation Guidelines.......................................................................... 10
3.1.1 Unpacking............................................................................................ 10
3.1.2 Ensuring Proper Airflow....................................................................... 10
3.2 Rack-Mounting................................................................................................... 11
3.3 Initial Operation.................................................................................................. 11
4 Service............................................................................................................. 12
4.1 Technical support and Return for Service Assistance....................................... 12
4.2 Declaration of Conformity.................................................................................. 12
4.3 Scope of Delivery............................................................................................... 13
4.4 Accessories ....................................................................................................... 13
4.5 Spare Parts........................................................................................................ 13
5 Technical Data ................................................................................................ 14
6 Dimensions ..................................................................................................... 15

CPCI Serial System 3+1 U
24579-415
www.schroff.biz 2 R1.0, July 20, 2011

CPCI Serial System 3+1 U Safety
24579-415
www.schroff.biz 1 R1.0, July 20, 2011
1 Safety
1.1 Intended Application
The CompactPCI Serial system, described in this manual, is intended as a
platform for a microcomputer system based on the CompactPCI Standard
CPCI Serial CPCI-S.0.
The case systems are designed for protection class IP 20 and can be used only
in the resp. environments.
CPCI system subracks are not end-products, so there is no valid approval for
this unit. In order to enable stand-alone functionality, additional elements are
required. An operational system is achieved only by way of appropriate CPCI
Serial boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the finished system complies with the safety regulations currently applicable
in the country it is going to be used.
• the finished system complies with all other regulations and specifications at
the place and country of use, e.g. interference limits, approval by the tele-
communications authorities.

CPCI Serial System 3+1 U Safety
24579-415
www.schroff.biz 2 R1.0, July 20, 2011
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.2.1 Safety Symbols used in this document
1.3 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. Familiarise yourself with the danger of
electrical voltages and the safety precautions to avoid accidents before
starting to work with parts that carry dangerous voltages.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
Static electricity can damage sensitive components in a system. To avoid
damage, wear ESD wrist straps or at regular intervals touch blank enclosure
parts.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

CPCI Serial System 3+1 U Product Definition
24579-415
www.schroff.biz 3 R1.0, July 20, 2011
2 Product Definition
The Schroff CPCI Serial system consists of:
• A shielded subrack with front card cage for
3 U boards according to IEEE 1101.x, IEC 20297.x and the CompactPCI
Standard CPCI Serial (CPCI-S.0)
• A 9 slot 3 U CPCI Serial backplane with Single Star Ethernet routing,
Part No.: 23007-612 (Full Mesh routing available on request)
• An ATX power supply (300 W) with wide range input, IEC320-C14 connector
and mains/line switch
• 1 U Fan Tray with 2 axial Fans (140 m³/h (85 cfm)) for the active cooling of
the boards
• Drive holder for an optional slim line DVD drive
• Drive holder for an optional 3.5“ HDD
2.1 References and Architecture Specifications
• User Guide Schroff CPCI Serial Backplanes 23007-61x
Order no.: 63972-277
Further information can also be found in the catalogue „Electronic Packaging“
and on the internet under www.schroff.biz

CPCI Serial System 3+1 U Product Definition
24579-415
www.schroff.biz 4 R1.0, July 20, 2011
2.2 System Overview
Figure 1: System Overview
2.3 Subrack
The 4 U chassis is based on the Schroff europacPRO system with EMC
shielding. The front card cage provides 9 CPCI Serial slots.
The lower guide rails of the card cage are equipped with ESD clips.
12311820
1Drive holder with front panel for an
optional 3.5“ HDD 5Front panel 3 U, 8 HP
2Drive holder for an optional slim line
DVD drive 6Handle
3ATX Power Supply 7Front Card cage with guide rails
4Fan Tray with 2 fans
Variations
The Schroff assembly service can customize your system with:
•Different Backplane configurations
•Drive mounting cassettes
•Special power supplies
More information in the catalogue or at www.schroff.biz

CPCI Serial System 3+1 U Product Definition
24579-415
www.schroff.biz 5 R1.0, July 20, 2011
2.4 CPCI Serial Backplane
Figure 2: Backplane front and rear view
23456789
1
17
28
15
GND +5V STNDBY12V12V12V12V GNDGNDGND
IPMB UTILITY

CPCI Serial System 3+1 U Product Definition
24579-415
www.schroff.biz 6 R1.0, July 20, 2011
2.4.1 Backplane topology
The CPCI Serial backplane with 9 slots supports the full set of serial links at all
slots.
The serial links (SATA/SAS, USB2/3, PCIe) are arranged as a Single Star
architecture.
Ethernet is implemented by 4 differential pairs in Single Star routing to support
10/100/1000/10GBase-T. (Full Mesh routing available on request)
More information in the Schroff Backplane manual, order no.: 63972-277
Figure 3: Backplane Topology
23007-612 (Ethernet Single Star)
Control
Indice
Altri manuali nvent Telaio