Ocean Insight FLAME-NIR+ Manuale utente

FLAMENIR+
Scientific-grade Spectrometer
Installation and Operation Manual
For Products: FLAME-NIR+, FLAME-NIR


Table of Contents
Before You Get Started .............................................. 1
Warnings & Cautions..................................................................................1
Warranty......................................................................................................3
Certifications and Compliance..................................................................3
Introduction............................................................... 6
Product Overview .......................................................................................6
Shipment Components ..............................................................................6
Calibration...................................................................................................7
Installation ................................................................ 8
Overview......................................................................................................8
Hardware Features.....................................................................................8
Accessories ................................................................................................9
Troubleshooting ...................................................... 12
I don’t see my spectrometer in OceanView............................................12
How do I know my spectrometer has power?........................................12
How do I know my spectrometer is transmitting data? ........................12
Connected to computer prior to software installation. .........................13
How do I determine if my computer is 32-bit or 64-bit?........................14
How do I check the configuration of my spectrometer? .......................14
Specifications..........................................................15
Spectrometer Specifications...................................................................15
Mechanical Diagram ................................................................................18
Electrical Pinout........................................................................................19
Detector Overview ....................................................................................22
Strobe Signals...........................................................................................23
External Triggering ...................................................................................24
Copyright © 2021 Ocean Insight
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying,
recording, or otherwise, without written permission from Ocean Insight.
This manual is sold as part of an order and subject to the condition that it shall not, by way of trade or otherwise, be lent, re-sold, hired out or otherwise circulated without
the prior consent of Ocean Insight, Inc. in any form of binding or cover other than that in which it is published.
Trademarks
All products and services herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Limit of Liability
Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an “as is”
basis. Ocean Insight shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this
manual.

Before You Get Started
Warnings & Cautions
This device may cause radio interference or may disrupt the operation of nearby equipment. It may be necessary to take
mitigation measures such as re-orienting, relocating, or shielding the location.
Cautions
Caution: Do not let contaminants get into the bench. Keep the protective cap on the slit aperture when not connected to an
accessory, probe or fiber.
Caution: Only change the slit aperture in a clean environment where contaminants including dust cannot enter the bench during the
procedure.
Caution: Substitution of a component or accessory different from that supplied may result in measurement error, equipment
damage, increased emissions or decreased immunity.
Caution: Be sure to install any software BEFORE connecting the spectrometer to your PC or host system. The software installs the
drivers required for spectrometer installation. If you do not install the software first, the system may not properly recognize
the spectrometer.
Caution: Repairs should be undertaken only by personnel trained or authorized by Ocean Insight. The device does not contain any
user serviceable parts.

MNL-1024 Rev A 2
Caution: Do not immerse the device in any fluid, place fluids on top of, or attempt to clean with liquid detergents or cleaning agents.
This may cause an electrical hazard. Do not use if accidental wetting occurs.
Caution: Do not remove any covers. Doing so may increase the risk of electrical shock or compromise the integrity of the optical
components.
Caution: Do not gas sterilize or autoclave this device.
Caution: Consult local codes and ordinances for proper disposal of equipment and other consumable goods.
Caution: The device and/or accessories may not operate correctly if used or stored outside the relevant temperature and humidity
ranges described in the Technical Specifications.
Caution: Do not use if device is dropped and/or damaged. Have an authorized service representative check the device before using
again.
Caution: To ensure reliable operation, it is recommended that the power supply be attached prior to inserting the USB connector.
Caution: The user of this spectrometer shall have the sole responsibility for any malfunction that results from improper use, faulty
maintenance, improper repair, damage, or alteration by anyone other than Ocean Insight or its authorized service
personnel.

MNL-1024 Rev A 3
Warranty
For the most current warranty information, please visit OceanInsight.com.
Certifications and Compliance
This is an FCC Class A product. In a domestic environment, this product may cause radio interference in
which case the user may be required to take adequate measures.
Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which the user will be required to
correct the interference at his own expense.
FCC Compliance
The authority to operate this equipment is conditioned by the requirement that no modifications will be
made to the equipment unless the changes or modifications are expressly approved by the
manufacturer.
Warning

MNL-1024 Rev A 4
The WEEE symbol on the product indicates that the product must not be disposed of with normal
household waste. Instead, such marked waste equipment must be disposed of by arranging to return to a
designated collection point for the recycling of waste electrical and electronic equipment. Separating
and recycling this waste equipment at the time of disposal will help to conserve natural resources and
ensure that the equipment is recycled in a manner that protects human health and the environment.
WEEE Compliance
ISO Certification
Ocean Insight, the industry leader in miniature photonics, has been certified for ISO 9001:2015
certification applicable to the design and manufacture of electro-optical equipment.
This device has been tested and complies with the following standards:
EN 61326-1:2013
This device has been tested and complies with the following standards:
Shock: IEC 60068-2-64
Vibration: IEC 60068-2-31

MNL-1024 Rev A 5
This device has been tested and complies with the following standards:
ICES-003, Class A
CISPR 11:2009/A1:2010
EMC 2014/30/EU
RoHS Compliant
This device complies with the following standards:
RoHS 2015-863

MNL-1024 Rev A 6
Introduction
Product Overview
Combining the small size of the Flame optical bench with an uncooled InGaAs detector, the Flame-NIR+ spectrometer opens a new
frontier in NIR spectroscopy. Without thermoelectric cooling, the Flame-NIR+’s power consumption is very low and makes the Flame-
NIR+ ideal for integration into handheld and portable systems.
The Flame-NIR+ offers a significant 6-fold enhancement in sensitivity over the previous Flame-NIR model. The additional sensitivity
has been achieved via enhancements to the optical performance of the unit. The electronics and interfacing of the Flame-NIR+ have
not been changed.
The Flame-NIR+ benefits from all the advantages of the Flame product line, including interchangeable slits and low unit-to-unit
variability. With a preconfigured range from 970 to 1700 nm, Flame-NIR+ is an ideal choice for many NIR applications including
moisture measurement, grain and feed quality, measurement of fats and oils, and pharmaceutical ingredients blending.
Shipment Components
❑Flame-NIR+
❑Micro USB Cable
❑Wavelength Calibration Data Sheet –Each spectrometer is shipped with a Wavelength Calibration Data Sheet that contains
information unique to your spectrometer.
NOTE
Please save the Wavelength Calibration Data Sheet for future reference.

MNL-1024 Rev A 7
Calibration
Each spectrometer is calibrated for wavelength before it leaves Ocean Insight; however, the wavelength for all spectrometers will
drift slightly as a function of time and environmental conditions. Additionally, Ocean Insight recommends that a calibration be
performed after changing the slit on a spectrometer as it will optimize the performance of the device.
For more information on performing a calibration, or using Ocean Insight’s Calibration Services, visit www.OceanInsight.com.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Ocean Insight Attrezzature da laboratorio






















