OEG KSW-E Series Manuale utente

KSW-E*, KSW*, KS2W*
Verschilregelaar
KSW-E*: 1 uitgang, 4 ingangen
KSW*: 2 uitgang, 6 ingangen
KS2W*: 3 uitgang, 6 ingangen
DUT
ENG Differential controller
KSW*: 1 output, 4 inputs
KSW*: 2 outputs, 6 inputs
KS2W*: 3 outputs, 6 inputs
DEU Differenzregler
KSW-E*: 1 Ausgäng, 4 Eingänge
KSW*: 2 Ausgänge, 6 Eingänge
KS2W*: 3 Ausgänge, 6 Eingänge
FRE Régulation différentielle
KSW-E*: 1 sortie, 4 entrées
KSW*: 2 sorties, 6 entrées
KS2W*: 3 sorties, 6 entrées
ITA Regolatori differenziali
KSW-E*: 1 uscita, 4 ingressi
KSW*: 2 uscite, 6 ingressi
KS2W*: 3 uscite, 6 ingressi


ENGDEUDUT
FREITA
Differential controllers
KSW-E*, KSW*, KS2W*
Differenzregler
KSW-E*, KSW*, KS2W*
Verschilregelaar
KSW-E*, KSW*, KS2W*
Régulation différentielle
KSW-E*, KSW*, KS2W*
Regolatori differenziali
KSW-E*, KSW*, KS2W*


ENG
5
INTRODUCTION
Differential controllers KSW-E*, KSW*, KS2W* are modern designed, microprocessor-
driven devices made with digital and SMT technology.
These devices are intended for regulating domestic hot water warming by means of solar
collectors or for regulating domestic hot water warming by means solid fuel boiler, electric
heater or other energy resources.
Differential controllers KSW-E*, KSW*, KS2W*
For initial setup see Initial controller setup, page 8!

ENG
6
CONTENTS
USER MANUAL
Appearance of controller ............................................................................................7
Initial controller setup...................................................................................................8
Graphic LCD display ................................................................................................ 10
Description of symbols shown on the display .......................................................... 11
Display for help, notices and warnings ......................................................................13
Menu entry and navigation ...................................................................................... 14
Menu structure and description ................................................................................ 15
Temperature settings................................................................................................ 18
User functions .......................................................................................................... 19
Operation mode selection......................................................................................... 20
Time program settings ............................................................................................. 21
Basic settings ........................................................................................................... 24
Data overview .......................................................................................................... 26
SERVICE MANUAL
Controller parameters and auxiliary tools ................................................................. 27
Basic parameters.................................................................................................. 27
Service parameters ............................................................................................. 30
Heat metering parameters ................................................................................... 34
Heat metering........................................................................................................34
Parameters for available outputs programming.....................................................36
Factory settings ....................................................................................................... 42
INSTALLATION MANUAL
Controller installation ............................................................................................... 43
Wall installation......................................................................................................... 43
Marking and description of temperature sensors ..................................................... 44
Controller’s electric connection..................................................................................45
Flow meter installation ............................................................................................. 46
Temperature simulation mode...................................................................................46
Flow setup and test of RPM control...........................................................................46
Technical data ...........................................................................................................47
Guarantie...................................................................................................................49
Declaration of conformity...........................................................................................50
Disposal of old electrical and electronic equipment...................................................50
Hydraulic and electric schemes...............................................................................237
Installation protocol..................................................................................................267

User and settings manual
ENG
7
1 - Graphic display.
2 - button (Esc - return to previous).
3 - button (one step back, decrease).
4 - USB connector for connecting personal computer.
5 - button (enters a menu, confirms selection).
6 - button (Help).
7 - button (one step forward, increase).
USER MANUAL
APPERANCE OF CONTROLLER
1
2
3
4 5 6 7

User and settings manual
ENG
8
INITIAL CONTROLLER SETUP
KSW-E*, KSW*, KS2W* differential controllers are equipped with an innovative solution
“Easy start”, which allows initial setup of the controller in only two steps.
When you connect the controller to the power supply for the first time, the software ver-
sion is shown. Next, the first step appears on the screen.
Using buttons and you select the required language.
Press the button to confirm the selected language.
After selecting the language, the controller requires
confirmation of the selection by pressing the
button.
If you accidentally selected the wrong language, go
back to reset the language by pressing button .
If you cannot find the required language on the first screen, move to the fol-
lowing screens by pressing the button .
STEP 1

User and settings manual
ENG
9
Selected hydraulic scheme can be later changed with service parameter S1.1.
Controller RESET!
Disconnect the controller from the power supply. Press and hold the button
and switch on power supply. The controller resets and goes to initial
setup.
CAUTION!
By selecting ‘reset’ all previous controller settings are erased.
Next, you select a hydraulic scheme for the controller
function. Move between schemes by means of buttons
and .
Confirm the selected scheme by pressing the
button.
STEP 2
After you selected the scheme, the controller requires
confirmation of the selection by pressing the
button.
If you accidentally selected the wrong scheme, go back
to reset the scheme by pressing button .

User and settings manual
ENG
10
Controller operation mode
Active
functions
Measured
temperatures,
state of output
and other data
Time and date
All important data of controller operation are shown on the graphic LCD display.
Advanced review of temperatures:
Measured temperature
Set point temperature
DESCRIPTION AND DESIGN OF THE MAIN DISPLAY:
For temperature and other data review we use buttons and .
Number of sensors and other data seen on the display depends on the selected hydraulic
scheme and controller settings.
2s
Which data are shown on the basic display depends on the selected scheme.
If we want to change the displayed information, press button or to
select the required data and confirm it by holding button for 2 se-
conds.
Messages
and warnings
State
of output
Diagram
of hydraulic
scheme
Measured
temperatures
GRAPHIC LCD DISPLAY
Questo manuale è adatto per i seguenti modelli
2
Indice
Lingue:
Altri manuali OEG Controllori