Omnicomm ICON Manuale utente

Omnicomm ICON Display
User Manual
07.09.2020

Contents
General Information
4
Screen controls and navigation
5
Screen chart
6
Technical Specifications
7
Setting
8
Calibration
10
Parameters Display on the Screen
12
Driver’s Status
15
Brightness
15
Notification Volume
16
Installation
16
Connection
17
Displayed Parameters
21
Operator’s Messages
22
Refueling Volume Monitoring
22
Driver Identification
23
Driver’s Status
24
Sound Notification
25
Panic Button
29

Use Cases
30
Monitoring the amount of remaining fuel, the refueling volume, and the vehicle's
operation parameters
30
Monitoring the fuel dispensing by a fuel tanker
35
Stationary tank with four fuel level sensors
40
Refrigerator with temperature sensors
46
Vehicle fleet with driver identification
50
Driving Safety Control
54
Construction Machinery
60
Driver Statuses in Omnicomm Online
66
Monitoring dispensing operations in Omnicomm Online
70

Omnicomm ICON Display
General Information
Omnicomm ICON display is intended to display various parameters, including:
Fuel volume in the fuel tanks
Refueling volume
Temperature according to the external temperature sensor readings
Fuel volume dispensed from the fuel-servicing truck (only in conjunction with the
Omnicomm Profi terminal)
Reading from the Omnicomm terminal universal inputs
Driver’s status
Driver name / registration
Vehicle speed
Current time
Dispatcher’s message
Engine hours
Omnicomm ICON Display is applicable:
in fleet monitoring systems, both with GPS/GLONASS terminals connection and
separately with fuel level sensors
with Omnicomm terminals 2.0 and later and with third generation built-in software
(302 and later)
with third-party terminals that support the Omnicomm ICON communication protocol
only with fuel level sensors using the Omnicomm LLS protocol and provided with the
RS-485 interface
4
General Information

While carrying out installation, observe the safety rules and regulatory requirements for
this type of work.
Screen controls and navigation
Omnicomm ICON display has 5 built-in buttons. To use the button you need, press the
display body frame.
5
General Information

Technical Specifications
Parameter Value
Power supply voltage, V From +8 to +35
Power consumption, W maximum 2
maximum 15 (when heated)
Type of output interface RS-485
1-wire interface iButton protocol
Omnicomm LLS sensors number 4
Baud rate through the RS-485 interface, bit/s 19,200 bit/s
Brightness 4 levels
Diagonal, inch 3,97
Resolution, dots 480 х 800
Active zone, mm 51,84 х 86,40
Sound notification volume 5 levels
Operating temperature range, °С From -30 to +80
Ingress protection rating IP51
Overall dimensions, mm 112,8 х 63,6 х 19,2
7
Technical Specifications

Weight, kg maximum 0.2 kg
Average service life 8 years
Parameter Value
Setting
Before setting the Omnicomm ICON display, disconnect the Omnicomm LLS fuel level
sensors.
Connect the Omnicomm ICON display to a РС using Omnicomm UNU-USB adapter
according to the diagram:
Run Omnicomm Configurator:
8
Setting

Select equipment – “Indicator”.
“Connection” – select the equipment to which the Omnicomm ICON display is
connected. Possible options: Fuel Level Sensor, Terminal
“Fuel level sensor operating mode” – select the data output mode for an LLS fuel level
sensor. Possible options: automatic data output, no automatic data output
“ICON network address” – set the Omnicomm ICON display network address. Default
value – 240
The “Used tanks” section is described in the Calibration subsection.
In the “Display mode” section:
“Authorization required” – check the box to enable driver identification using the
MIFARE Ultralight card. For successful identification the terminal should be configured
according to the terminal user manual, the Omnicomm ICON Display section
“Respond to threshold exceeding” – check the box to enable sound notification when
registering the event set according to the Parameters display on the screen subsection
“Slideshow” – check the box to enable automatic switching of the main screens in
slideshow mode. Configure the main screens according to the Parameters display on
the screen subsection
9
Setting

Press the “Record into device” button
Calibration
Omnicomm ICON display supports up to 4 fuel tanks. The maximum number of
Omnicomm LLS fuel level sensors is 4.
To add calibration tables for fuel level sensors, in the “Used tanks” section press the “Add
tank” button.
A window will open, where you select a .ctb file with calibration tables for
Omnicomm LLS fuel level sensors.
To view and edit the calibration tables, press the “Calibration tables” button.
10
Setting
Indice