Model: W182FLT / W183FLT
3 STAR 2 STAR

Dear customer
Congratulation on buying ONIDA Air Conditioner.
Your Air Conditioner comes with ONIDA Guarantee of Quality
as detailed in the manual.
ONIDA takes great pride in providing its customers with state-
of-the-art products that adheres to international quality
standards.
ONIDA is committed to following quality policy laid by our
chairman and managing director Mr. G. L. Mirchandani.
“We are committed to quality and strive for continuous
improvement through innovation and human development to
give customer better value for money always”
ONIDA stands committed to provide the ultimate customer
satisfaction, as nothing brings us greater joy than having
satisfied customers of ONIDA.
At ONIDA, feedback and suggestions based on your product
usage experience is greatly appreciated.
Please contact to us at r[email protected]
Chief Executive Officer
IMPORTANT :
Please read this owner’s manual carefully and thoroughly
before installing and operating your room air conditioners.
Please retain this owner’s manual for future reference after
reading it thoroughly.
Dr. Y. V. Verma

CONTENTS
Salient Features 1
Control Panel 3
Remote Overview 4
Operations 5
Safety Precautions 11
Installation 13
Electrical Requirements 17
Take care of your Air Conditioner 18
Precautions to be taken 19
Trouble Shooting Chart 21
Installation and Satisfaction Report 23
Warranty Terms & Conditions 25
Preventive Maintenance Service Coupon 27
Warranty Card(Customer Copy) 29
Warranty Card(service Center Copy) 31
Inside Air Conditioner 2

SALIENT FEATURES
1.5T Window Air Conditioner
W182FLT / W183FLT
a) 3 Star / 2 Star Energy Saver BEE Rated
d) Full Function LCD Remote
e) Gold Fin
Model Code :
• Aesthetics:-
a) Unique Flat Panel
• Performance:-
b) High BTU Compressor
c) Trapezoidal Inner Grooved Tube
d) Large Condenser Coil
• Features:-
a) Combined Timer
b) Auto-Restart
c) Multi Fan Speeds
• Safety & Reliability:-
a) Low Deration Factor
b) Hydrophilic Fins for Evaporator
c) 5-Stage Epoxy Polyester Painting
d) Rugged Construction With Thicker Gauge Steel
1

32
CONTROL PANEL
INSIDE THE AIR
CONDITIONER
1. Front panel
2. Air filter
3. Frame
4. Cabinet
5. Air inlet grill (outdoor side)
6. Air outlet grill
7. Electronic control keypad
8. Power supply cord
9. Remote control
FEATHER TOUCH:
1. “Power” Key
ŸPower button to ON/OFF the Air Conditioner.
2. “Mode” Key
ŸToggles between Auto/Cool/Dry/Fan Modes.
3. “Temp/Timer Adjustment” Key
ŸAdjust the temperature/timer setting.
4. “Fan Speed” Key
Ÿ Toggles the Fan speed between High, Low and Auto.
5. “Remote Sensor”
6. “Room Temp Display”
7. “Timer” Key
Ÿ Toggles between Timer ON and Timer OFF.
8. “Swing” Key
Ÿ To adjust the airflow direction.
The unit displayed in manual are for representational purpose only. Actual unit may vary.
POWER
TEMP
TIME
HIGH
MID
LOW
DRY
FAN
COOL
MODE
SWING
ON/OFF
TIMER
ON/OFF
SPEED
FAN
1
23
4
5
68
7
Accessories
Seal
(Used on
drain joint)
1
1
Screw
Drain Joint
1 pec
Water outlet pipe
1pec
Drain Tray
MODE SWING
SLEEP
TIMERFAN

54
REMOTE OVERVIEW OPERATIONS
1. Open back cover and put 2 Nos. AAA size alkaline batteries.
2. The remote signal can be reached up to six meters from the Air Conditioner Receiver.
3. When the button is pressed on remote, Unit will “beep” once, indicating the receipt of
signal. If no “beep” sound is heard, press the button once again.
4. Remove batteries if remote control has not been used for long time.
5. Heat mode is not available with all models.
Operating Your Air Conditioner:
Your Window Air Conditioner can be conveniently operated using the intelligent cordless
remote control.
1. Switch on the MCB.
Press ON/OFF button on remote handset to switch ON the AC.
All icons will glow once.
Your AC switches on with parameters that were set before power was switched
off. The unit receives the signal with "BEEP" tone and your AC starts operation.
Time Delay: To protect the compressor, a time delay is incorporated in the circuit.
The Time Delay ensures that the compressor switches ON only after a delay of about 3
minutes.
2. Press the “MODE” Button for Auto, Cool, or selection.
3. Press the "FAN” Button to set the Fan Speed. Each press changes the fan speed
from Low- Med - High Fan speed. The selected fan setting symbol can be
seen on the LCD.
4. The Set Temp. is displayed on LCD, Press button ” “ to increase and “ “ to the
decrease the temperature.
5. To switch off the AC, press the same ON/OFF Button.
Setting the Desired Room Temp.:
You can set the temp. at which you would like your room to be.
O
Press " " button to increase the set temp. On every press, the temp. increases by 1 C.
O
Press " " button to decrease the set temp. On every press, the temp. decreases by 1 C
The two digit display shows the set temp. on LCD.
O
The setting temp. range is from 16- 32 C.
Dry Fan
Your window AC operates in one of four modes, AUTO-COOL-FAN-DRY. The modes
button cyclically chooses between these operating modes.
*Cooling capacity measured at High speed, as per IS 1391:1992 Part 1
Signal ejecting window
MODE SWING
SLEEPTIMERFAN
SLEEP
SWING
BACK VIEW
RESET
CLOCK *

76
OPERATIONS OPERATIONS
Your Window AC operates in one of four modes, COOL-DRY- . The modes button
cyclically chooses between these operating modes.
The AUTO Mode :
1. Press "MODE" button to cyclically step through the AUTO-COOL-DRY-FAN modes and
stop when AUTO mode is selected.
2. symbol can be seen on the Remote panel when you select the AUTO mode.
3. In this mode, the fan speed can be changeable.
0
4. Temperature can be pre-set in this mode, default temperature is 25 C.
5. In the AUTO mode, your AIR CONDITIONER "Thinks” for you.
The unit automatically and continuously monitors the difference between room temp.
and set temp. and adjusts the fan speed accordingly, to ensure maximum comfort.
The COOL mode:
In the cool mode, the compressor is in operation and your AC functions in the standard
operating mode, cooling your room to the desired set temp.
1. Press "MODE" button to cyclically step through the AUTO-COOL-DRY-FAN modes and
stop when cool mode is selected.
2. symbol can be seen on the Remote panel & LED will glow on display panel when
you select the cool mode.
In this mode, you can change the temp. settings by pressing " " and “ ” temp.
buttons.
You can change the fan speed setting by pressing FAN button.
3. If the Room temp. is more than the set temp., then the compressor will remain ON
and perform the Cooling operation. If the room temp. achieves the temp. less than set
temp., then the compressor will remain OFF.
The DRY Mode:
In the DRY mode, your AC reduces the humidity within the room faster.
1. Press "MODE" button to cyclically step through the AUTO-COOL-DRY-FAN modes and
stop when DRY mode is selected.
2. symbol can be seen on the Remote panel & LED will glow on display panel when
you select the DRY mode.
3. In DRY mode, Temperature and FAN Speed cannot change. Default pre-set
0
temperature is 25 C. FAN will run at low speed. Compressor work as per the
Temperature difference.
AUTO- FAN The FAN Mode:
1. Press "MODE" button to cyclically step through the modes
and stop when FAN mode is selected.
2. symbol can be seen on the Remote panel & LED will glow on display panel
when you select the FAN mode.
3. In FAN mode, only FAN will run at set speed and Compressor will remain off.
Temperature will be displayed on display panel. Temperature setting can be
changed.
4. In this mode, you can change the FAN Speed.
TIMER Operation:
You can program your AC to switch itself ON or OFF at particular time.
Maximum set time is 24 hrs, with 1.0 hr increment .
ON TIMER:
When the AC is "OFF" (in standby), press "TIMER" Button on remote to use this feature as
the TIMER. (make sure that MCB switch is "ON". The "TIMER" light on Display panel will
glow ON.
For EXAMPLE:
Suppose you want to switch ON the AC after 8 hrs. Press "TIMER" button, when AC is in
OFF condition.
Press "TIMER" button to set ON timer. Display on Remote will show "8”.
OFF TIMER:
When the AC is "ON", press "TIMER" Button on remote to use this feature as
the TIMER. The "TIMER" light on Display panel will glow ON.
For EXAMPLE:
Suppose you want to switch OFF the AC after 8 hrs. Press "TIMER" button, when AC is in
ON condition.
Press "TIMER" button to set OFF timer. Display on Remote will show "8”.
CANCEL TIMER:
If you want to cancel either TIMER ON or TIMER OFF, press the TIMER button till the
timer becomes blank.
AUTO-COOL-DRY-FAN

9
8
OPERATIONS
NOTE: Upto 10 hrs, setting time increment will be 0.5 hrs, after 10 hrs setting time
increment will be 1 hrs.
SLEEP Operation:
To switch on SLEEP operation, Press SLEEP button on remote.
0
In this mode, the set temperature will increase by 1 C over the next 1hour and by another
0
2 C after an additional 1 hour. This new temperature will be maintained for 5 hours
before it returns to the original selected temperature. Then unit will goes off.
Press again to cancel SLEEP operation.
NOTE:- The SLEEP function is only available under COOL and AUTO Modes only.
SWING Operation :
Press “SWING” button to adjust the airflow direction.
Press it again to stop.
OPERATIONS
Vent Control
CLOSE VENT OPEN CLOSE OPEN
Vertical air flow adjustment (manually)
The Vent control is located above the control knobs. The operation is different
on different models (see below figures).
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation.
OPEN the vent to discharge stale air.
To open the vent, pull the lever toward you To open the vent, set the lever to the right
position.To close it, push it in. To close it, set the lever in the left position.
To adjust vertical air flow direction, adjust any one of the
horizontal louver blades. When adjusting the horizontal
louver blades up and down, always keep the top or bottom
blades horizontal. This can effectively prevent water droplets
condensing on the front panel of the unit.

1110
SAFETY PRECAUTIONS
Plug in the power plug
properly.
Do not operate or stop the
unit by inserting or pulling
out the power plug.
Do not damage or use an
unspecified power cord.
Otherwise , it wil l caus e electric
shock or fire due t o heat
generatio n o r electrica l shock.
I t wil l cau s e electrica l shock or fire
due to hea t generation.
It will cause electrica l shock or fire.
I f th e supply cor d is damaged , it
must be replaced by a specia l cord
or assembly availabl e fro m the
manufacture r or its servic e agent.
Do not modify power cord
length or share the outlet
with other appliances.
Do not operate with wet
hands or in damp
environment.
Do not direct airflow at room
occupants only.
I t wil l c ause electrica l shock or
fire due to hea t generation.
It ma y cause electrica l shock.
Thi s coul d damag e you r health.
Never touch th e metal parts
of th e uni t when removing
th e filter.
Do not clean the air
conditioner with water.
Ventilate wel l when used
together wit h a stive , etc.
I t may cause a n injury. Wate r may enter th e uni t and
degrad e th e insulation . I t may
caus e a n electri c shock.
An oxyge n shortag e may occur.
To prevent injury to the user or other people and property damage, the following instructions must
be followed.
ŸIncorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is
classified by the following indications.
SAFETY PRECAUTIONS
When cleaning the unit , first
mak e sur e th e power and
breaker are turned off.
Do not put a pet or house
plant wher e it wil l be
exposed to direct air flow.
Do no t us e fo r special
purposes.
Sinc e th e fa n rotate s a t high
spee d durin g operation, i t may
caus e a n injury.
Thi s coul d injure th e pe t or plant. D o not us e thi s ai r conditione r to
preserv e precisio n devices , food,
pets, plants , an d ar t objects.
I t ma y caus e deterioration of
quality, etc.
Do no t operate Switches
wit h we t hands.
Do no t apply an insecticide
or flammable spray.
Do no t put a heater, etc.
where is exposed to direct air
flow.
I t may cause a n electri c shock. I t may cause a fire or deformation
of the cabinet.
I t ma y cause imperfect combustion.

1312
INSTALLATION
Over 50cm
About 10mm
FENCE
AWNING
75-150cm
Over 50cm
About 10mm
FENCE
AWNING
75-150cm
All side louvers of the cabinet must remain exposed to the outside of the structure.
CAUTION
Select the best location
1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit.
If the unit receives direct sunlight, build an awning to shade the cabinet.
3. There should be no obstacle, such as a fence or wall, withing 50cm from the back of the
cabinet because it will prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling and heating efficiency of the air
conditioner.
4. Install the unit a little obliquely outward not to leak the condensed water into the room
(about 10mm or 1/4 bubble with level).
5. Install the unit with its bottom portion 75~150cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green wire must
be grounded.
Installation of the Housing
Step 1
Remove the air conditioner from it’s packaging, remove fixing screws and slide the air
conditioner out of it’s housing (Refer to installation Steps).
Step 2
Prepare the hole in the wall so that the bottom of the housing is well supported, the top
has minimum clearance and the air inlet louvers have clearance as shown below in
options A and B. Holes from the outside through to the cavity should be sealed. The
housing should slope down towards the rear by about 5mm to allow water formed during
operation to drain.
Step 3
Install the housing into the wall and secure. Ensure the foam seals are not damaged.
Flash, seal or fill gaps around the inside and outside to provide satisfactory appearance
and protection against the weather, insects and rodents.
NOTE: UNIT MAY BE SUPPORTED BY A
SOLID FRAME FROM BELOW OR
BY A HANGER FROM A SOLID
OVERHEAD SUPPORT.
Preferred method of installation into a timber
framed wall, partition or window.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
TIMBER FRAMED
WALL OR PARTITION
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF A/C
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
DRAIN PAN
INSTALLATION
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Onida Condizionatore d'aria

Onida
Onida S09TRD-N4 Manuale utente

Onida
Onida INV18SLU-C8 Manuale utente

Onida
Onida S123CUR Manuale utente

Onida
Onida INV18SMT7 Manuale utente

Onida
Onida S09FLT-L3 Manuale utente

Onida
Onida S12SPD-M3 Manuale utente

Onida
Onida INV18SLH8 Manuale utente

Onida
Onida INV18ELE7 Manuale utente

Onida
Onida OV-R224P/Na-M Manuale utente

Onida
Onida SI12TRD3 Manuale utente