Osburn OSBURN 1000 Manuale utente

READ AND KEEP THIS MANUAL FOR REFERENCE
45126A
20-10-2011
OWNER`S MANUAL
OSBURN MODEL 1000 FREESTANDING STOVE
Distributed by
Glen Dimplex Australasia
NEW ZEALAND
38 Harris Road, East Tamaki, Auckland
Ph: 09 274 8265 Fax 09 274 8472
Email:[email protected]
www.masportheating.co.nz
AUSTRALIA
Unit 2,205 Abbotts Road
Dandenong South, Victoria 3175
Ph: 1 300 566 816 Fax 8787 3570
www.masportheating.com.au


2
TABLE OF CONTENTS
INTRODUCTION..............................................................................................................................3
TECHNICAL SPECIFICATIONS...................................................................................................4
DOOR OVERLAY INSTALLATION.............................................................................................5
DOOR ADJUSTMENT.....................................................................................................................6
INSTALLATION...............................................................................................................................7
POSITIONING THE STOVE..........................................................................................................8
FLOOR PROTECTOR.....................................................................................................................8
CLEARANCES TO HEAT-SENSITIVE MATERIALS.................................................................9
REDUCED CLEARANCES USING SHIELDING.......................................................................10
OPERATING AND MAINTENANCE INSTRUCTIONS...........................................................12
TESTING YOUR WOOD..............................................................................................................13
THE FIRST FIRES.........................................................................................................................13
LITHING THE FIRE .....................................................................................................................14
HEATING......................................................................................................................................15
RELOADING ................................................................................................................................16
CREOSOTE FORMATION AND NEED FOR REMOVAL.........................................................16
ASH DISPOSAL............................................................................................................................17
ASH DISPOSAL USING ASH DRAWER....................................................................................17
PAINT............................................................................................................................................19
REPLACEMENT PARTS .............................................................................................................19

3
INTRODUCTION
Glen Dimplex Australasia congratulates you on your purchase and wishes to help you get
maximum satisfaction from your wood stove. In the pages that follow, we will give you
advice on wood heating and controlled combustion as well as technical specifications
regarding installation, operation and maintenance of the model you have chosen.
The instructions pertaining to the installation of your wood stove comply with AS/NZS4013
and AS/NZS2918 standards.
Read this entire manual before you install and use your new stove. If this stove is
not properly installed, a house fire may result. To reduce the risk of fire, follow the
installation instructions.
Consult your local city, borough or shire council about restrictions and installations
requirements in your area and the need to obtain a permit.
Keep this instruction manual for future reference.
CAUTIONS:
HOT WHILE IN OPERATION.KEEP CHILDREN,CLOTHING AND FURNITURE AWAY.CONTACT MAY
CAUSE SKIN BURNS.
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
DO NOT BURN WASTES,FLAMMABLE FLUID SUCH AS GASOLINE,NAPHTHA OR MOTOR OIL.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.

4
TECHNICAL SPECIFICATIONS
Combustible: Wood
Maximum heat output – hardwood (Australia): 15 kW
Efficiency – hardwood (Australia): 66 %
Emissions – hardwood (Australia): 1.5 g/kg
Color : Metallic black
Flue Spigot Diameter : 152 mm
Flue system : Standard
Minimum Flue Height (from floor protector): 4.6 meters
Maximum Log Length : 406 mm
Overall dimensions W x D x H
(595 x 595 x 744mm)
Combustion Chamber :
Width x Depth :
Volume :
W x D
(457 x 381 mm)
0,043 m3
Door Opening Dimensions:
W x H
209 x 394 mm
Weight: 114 Kg

5
DOOR OVERLAY INSTALLATION
In order to complete the assembly of your Osburn 1000 wood stove, you need to install the
door overlay. See figure 1 below for installation instructions :
1- Position the overlay on the door frame and fix it in place from behind using the
4 screws.
Note: It is not necessary to remove the glass or any other component to install the overlay.
Figure 1 : Door overlay installation

6
DOOR ADJUSTMENT
In order for your stove to operate properly, the door should be adjusted periodically to
provide an air tight fit. To adjust:
Remove the lock pin (spring pin) by pulling and turning it using pliers ("Vise grip")
Turn the handle counter clock wise one turn to increase pressure
Re-install the lock pin (spring pin) with a small hammer
Figure 2 : Door Adjustment

7
INSTALLATION
IT IS RECOMMENDED THAT THE INSTALLATION OF YOUR OSBURN WOODFIRE BE
CARRIED OUT BY A QUALIFIED SPECIALIST INSTALLER.
IF ANY ELECTRICAL WORK IS REQUIRED, IT MUST BE CARRIED OUT BY A
LICENSED ELECTRICIAN.
WARNING: The instructions pertaining to the installation of your wood stove comply with
the AS/NZS 2918 standard. THE APPLIANCE AND FLUE SYSTEM MUST THEREFORE
BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD
SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED
BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE
BY A COMPLIANCE PLATE WITH THE MARKING “TESTED TO AS/NZS 4013”.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF
THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013.
CAUTION:
MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS
CONDITIONS.WHERE SUCH ACTION IS CONSIDERED,THE MANUFACTURER SHOULD BE
CONSULTED IN THE FIRST INSTANCE.
CRACKED AND BROKEN COMPONENTS,e.g. GLASS PANELS OR CERAMIC TILES,MAY RENDER THIS
INSTALLATION UNSAFE.
USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
ASOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN
REQUIRED.
IF THIS STOVE IS NOT PROPERLY INSTALLED,A HOUSE FIRE MAY RESULT.TO REDUCE THE RISK
OF FIRE,FOLLOW THE INSTALLATION INSTRUCTIONS.
CONSULT YOUR CITY,BOROUGH OR SHIRE COUNCIL ABOUT RESTRICTIONS AND INSTALLATIONS
REQUIREMENTS IN YOUR AREA.
KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
NEVER USE GASOLINE,GASOLINE-TYPE LANTERN FUEL,KEROSENE,CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR "FRESHEN UP"A FIRE.KEEP ALL SUCH LIQUIDS WELL AWAY
FROM THE STOVE.
IN THE EVENT OF A CHIMNEY FIRE,PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE
OF OXYGEN.CALL THE FIRE DEPARTMENT.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.

8
POSITIONING THE STOVE
It is very important to position the wood stove as close as possible to the chimney, and in
an area that will favour the most efficient heat distribution possible throughout the house.
The stove must therefore be installed in the room where the most time is spent, and in the
most spacious room possible. Recall that wood stoves produce radiating heat, the heat
we feel when we are close to a wood stove. A wood stove also functions by convection,
that is through the displacement of hot air accelerated upwards and its replacement with
cooler air. If necessary, the hot air distribution from the stove may be facilitated by the
installation of a blower.
The wood stove must not be hooked up to a hot air distribution system since an
excessive accumulation of heat may occur.
A wood stove must never be installed in a hallway or near a staircase, since it may
block the way in case of fire or fall to respect required clearances.
FLOOR PROTECTOR
Your wood stove should be placed on a non-combustible surface. Install a floor protection
using a 6mm thick fibre cement sheet with thermal conductivity of 0.41W/m degree K
underneath the heater.
The floor protector should project beyond the stove as follows:
Minimum Distance From the Door Opening
FRONT
300 mm
SIDES
200 mm
BACK
N/A

9
CLEARANCES TO HEAT-SENSITIVE MATERIALS
It is of outmost importance that the clearances to heat-sensitive materials be
carefully maintained upon installation of the stove you have selected. Refer to the
table below :
CLEARANCES TO HEAT SENSITIVE MATERIALS
Model A B C D E
OSBURN 1000 100mm 350mm 150mm 300mm 100mm*
*200 mm from door opening.
Floor to ceiling height must be at least 1,500 mm in all cases.
The clearance between the flue pipe and a wall are valid only for vertical walls and for
vertical flue pipe.
WHERE THE FLUE PASSES THROUGH WALLS,CEILINGS OR ROOFS,VENTILATED DOUBLE FLUE-
PIPE CASINGS MUST BE USED AROUND THE FLUE PIPE,ALONG WITH CEILING PLATES AS
SPECIFIED IN AS/NZS2918:2001.
Altri manuali per OSBURN 1000
2
Indice
Altri manuali Osburn Stufa

Osburn
Osburn Inspire 2000 OA10243 Manuale utente

Osburn
Osburn Romance 28 Manuale utente

Osburn
Osburn 50 Series Specifiche tecniche

Osburn
Osburn 1100 Manuale utente

Osburn
Osburn BRITANNIA 31 Manuale utente

Osburn
Osburn Hybrid-35MF Manuale utente

Osburn
Osburn OB01010 Manuale utente

Osburn
Osburn LA 30 Manuale utente

Osburn
Osburn OB01520 Manuale utente

Osburn
Osburn Bay Vista Manuale utente