Ovation P19 Manuale utente

USER MANUAL
19 x 15W LED ZOOM PAR
P19

Caution!..................................................................................................................3
Introduction............................................................................................................3
Safety instructions ................................................................................................3
Overview.................................................................................................................3
Installation..............................................................................................................4
Read ‘Safety information’ before installing the xture. ...................................................................4
Fastening the xture to a flat surface ................................................................................................4
Mounting the xture on a truss ..........................................................................................................4
Securing with a safety cable...............................................................................................................4
DMX-512 connection/connection between xtures..........................................................................4
Power connection................................................................................................................................5
Operation................................................................................................................5
Addressing ...........................................................................................................................................6
Universal DMX Control........................................................................................................................6
Control Menu Map .................................................................................................6
DMX Protocol.........................................................................................................7
Fixture Cleaning ..................................................................................................15
Fuse Replacement...............................................................................................15
Troubleshooting ..................................................................................................15
The xture does not work, no light ................................................................................................. 15
Technical specications.....................................................................................16
Table of contents

3V1.0
Caution!
Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric
shock when touching the wires!
Avoid looking directly into the light source!
Wear protective glasses and other PPE (personal protective equipment) when working on or near
the xture.
For your own safety, please read this user manual carefully before you initial start-up.
Follow operating safety precautions and pay attention to warning signs methods and equipment
on the user manual.
Indoor use only! To prevent risk of re or shock, do not expose this product to rain or moisture. IP
20 rating.
The ambient temperature must always be between -5° C and +45° C.
Always make sure you are connecting this product to the proper voltage in accordance with the
specications in this manual or on the product’s specication label.Make sure it is grounded when
using it!
Unplug mains lead before opening the housing!
Make sure that the power cord is never crimped or damaged by sharp edges. Check the xture
and the powercord from time to time.
Make sure to replace the fuse with another of the same type and rating.
Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot
during operation. After use, wait for a cool-down period of at least 10 minutes before handling or
transporting the device.
Every person involved with the installation, operation and maintenance of this device has to
- be qualied
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
Introduction
Thank you for having chosen P19. You will see you acquired a powerful and versatile device.
Unpack your item. Before you initial start-up, please make sure that there is no damage caused by trans-
portation. Should there be any, consult your dealer and do not use the device.
Safety instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warn-
ing notes written in this user manual. Always disconnect from the mains, when the device is not in use
or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts
inside the device. Maintenance and service operations are only to be carried out by authorized dealers.
Overview

4V1.0
Installation
Read ‘Safety information’ before installing the xture.
The xture is designed for indoor use only and must be used in a dry location with adequate ventilation.
Ensure that none of the xture’s ventilation slots are blocked.
Fasten the xture to a secure structure or surface. Do not stand it on a surface or leave it where it can
be moved or fall over. If you install the xture in a location where it may cause injury or damage if it falls,
secure it as directed in this user manual using a securely anchored safety cable that will hold the xture if
the primary fastening method fails.
Fastening the xture to a flat surface
The xture can be fastened to a hard, xed, flat surface that is oriented at any angle. Ensure that the sur-
face and all fasteners used can support at least 10 times the weight of all xtures and equipment to be
installed on it.
Fasten the xture securely. Do not stand it on a surface or leave it where it can be moved or fall over. If
you install the xture in a location where it may cause injury or damage if it falls, secure it as directed be-
low with a securely anchored safety cable that will hold the xture if the primary fastening method fails.
Mounting the xture on a truss
The xture can be clamped to a truss or similar rigging structure in any orientation. When installing the
xture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in
any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.
To clamp the xture to a truss:
1. Check that the rigging structure can support at least 10 times the weight of all xtures and equipment
to be installed on it.
2. Block access under the work area.
3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting
bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting
bracket legs and be fastened with a self-locking nut.
4. Working from a stable platform, hang the xture with its clamp on the truss and fasten the clamp se-
curely.
5. Secure the xture with a safety cable as directed below.
Securing with a safety cable
Secure the xture with a safety cable (or other secondary attachment) that is approved for the weight of
the xture so that the safety cable will hold the xture if a primary attachment fails.
Loop the safety cable through the eyebolt in the back of the xture and around a secure anchoring point.
Do not loop the safety cable around the xture’s mounting bracket only, as this will leave the xture un-
secured if it separates from the bracket.
DMX-512 connection/connection between xtures
Occupation of the XLR-connection:

5V1.0
1. Group
2. Signal (-)
3. Signal (+)
DMX OUT
1. Group
2. Signal (-)
3. Signal (+)
DMX IN
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture.
Always connect one output with the input of the next xture until all xtures are connected.
DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an electrically noisy environ-
ment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with
a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket of the
last xture in the chain.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω re-
sistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last
xture.
Power connection
Power Requirements
The P19 luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an
auto-ranging power supply.
Power linking between fixtures:
The xture with powercon in and out socket. Connect the power out to the power in socket in the next x-
ture till all are connected.
Caution: maximum power linking - 6 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color Connection International
Brown Live L
Blue Neutral N
Yellow/green Earth(Ground)
Operation
The P19 can operate in three different modes. In each mode you can run the xture as a stand alone
fixture or in a master/slave confiugration. This next section will detail the differences in the operating

6V1.0
modes.
Addressing
All xtures should be given a DMX starting address when using a DMX signal, so that the correct xture
responds to the correct control signals. This digital starting address is the channel number from which
the xture starts to listen to the digital control information sent out from the DMX controller. The alloca-
tion of this starting address is achieved by setting the correct number on the display located on the base
of the device.
You can set the same starting address for all xtures or a group of xtures, or make different address for
each xture individually.
If you set the same address, all the units will start to listen to the same control signal from the same
channel number. In other words, changing the settings of one channel will affect all the xtures simulta-
neously.
If you set a different address, each unit will start to listen to the channel number you have set, based on
the quantity of control channels of the unit. That means changing the settings of one channel will affect
only the selected xture.
In the case of the P19, which is 32/10/10/5/32 channels xture. If you set, for example, the address in the
5 channel mode to channel 6, the device will use the channel 6 to 10 for control.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX
controller allows you to create unique programs tailored to your individual needs.
Control Menu Map
Default seeting in bold.
Main Menu Level 1 Level 2 Level 3 FUNCTION INSTRUCTION
Address 001-512 DMX address setting
RUN
DMX512
Control mode
Auto1
Auto2
Sound1
Sound2
DMX MODE
Mode1(32CH) Channel mode 1 = 32CH
Mode2(16CH) Channel mode 2 = 16CH
Mode3(10CH) Channel mode 3 = 10CH
Mode4(5CH) Channel mode 4 = 5CH
Mode5(32CH) Channel mode 5 = 32CH
TEST LED Test mode
SET
Disp.Setting
Display 02-60m Display shut off when no operation
Key lock ON/OFF Buttons lock when no operation
Flash ON/OFF
INFO Time info
Power on 0001(Hours)
Fxiture information
Ttl Life Hrs 0007(Hours)
Last Run
Hrus 0002(Hours)
Software V. V1.00 Software version
MANUAL Functions 000-255 Manual setting on board
Red 000-255

7V1.0
Green 000-255
Blue 000-255
White 000-255
Clours 000-255
Zoom 000-255
Strobe 000-255
Dimmer 000-255
RESET All reset Yes/No Reset
DMX Protocol
Mode1 (32 CH) Value Function
CH1
Special functions
000-49 Reserved
050-179 Reserved
180-189 Zoom Reserved
190-255 Reserved
CH2 000-255 Red(8bit)-zone 1
Red LEDs saturation control (0-100%)
CH3 000-255 Red ne (16 bit) - zone 1
Fine red LEDs saturation control
CH4 000-255 Green (8 bit) - zone 1
Green LEDs saturation control (0-100%)
CH5 000-255 Green ne (16 bit) - zone 1
Fine green LEDs saturation control
CH6 000-255 Blue (8 bit) zone 1
Blue LEDs saturation control (0-100%)
CH7 000-255 Blue (16 bit) zone 1
Fine blue LEDs saturation control)
CH8 000-255 White (8 bit) - zone 1
White LEDs saturation control (0-100%)
CH9 000-255 White (16 bit) - zone 1
Fine white LEDs saturation control
CH10 000-255 Red ( 8bit) - zone 2
Red LEDs saturation control (0-100%)
CH11 000-255 Red ne (16 bit) - zone 2
Fine red LEDs saturation control)
CH12 000-255 Green (8 bit) - zone 2
Green LEDs saturation control (0-100%)
CH13 000-255 Green ne (16 bit) - zone 2
Fine green LEDs saturation control
CH14 000-255 Blue (8 bit) - zone 2
Blue LEDs saturation control (0-100%)
CH15 000-255 Blue ne (16 bit) - zone 2
Fine blue LEDs saturation control
CH16 000-255 White (8 bit) - zone 2
White LEDs saturation control (0-100%)
CH17 000-255 White ne (16 bit) - zone 2
Fine white LEDs saturation control
CH18 000-255 Red (8 bit) - zone 3
Red LEDs saturation control (0-100%)
CH19 000-255 Red ne (16 bit) - zone 3
Fine red LEDs saturation control

8V1.0
Mode1 (32 CH) Value Function
CH20 000-255 Green (8 bit) - zone 3
Green LEDs saturation control (0-100%)
CH21 000-255 Green ne (16 bit) - zone 3
Fine green LEDs saturation control
CH22 000-255 Blue (8 bit) zone 3
Blue LEDs saturation control (0-100%)
CH23 000-255 Blue ne (16 bit) zone 3
Fine blue LEDs saturation control
CH24 000-255 White (8 bit) zone 3
White LEDs saturation control (0-100%)
CH25 000-255 White ne (16 bit) zone 3
Fine white LEDs saturation control
CH26
Color temperature
000 No function
001-255 Colour temperature correction from 20000K to 2700K(menu
item “Colour Calibration Mode”=Off)
CH27
Virtual Colour Wheel
For detailed description see “ Virtual colour wheel- colour mixing
chart
000 No function
001-002 White 2700 K
003 White 2700 K (Halogen lamp mode*)
004-005 White 3200 K
006 White 3200 K (Halogen lamp mode*)
007-009 White 4200 K
010-012 White 5600 K
013-015 White 8000 K
016 Blue (Blue=full, Red+Green+White=0)
017-055 Red=0, Green->up,Blue =full, White=0
056 Light Blue (Red=0, Green=full, Blue =full, White=0)
057-095 Red=0, Green=full, Blue->down, White=0
096 Green (Red=0, Green=full, Blue =0, White=0)
097-134 Red->up, Green=full, Blue=0, White=0
135 Yellow (Red=full, Green=full, Blue=0, White=0)
136-174 Red=full, Green->down, Blue=0, White=0
175 Red(Red=full, Green=0, Blue=0, White=0)
176-214 Red=full, Green=0, Blue->up, White=0
215 Magenta (Red=full, Green=0, Blue=full, White=0)
216-246 Red -> down, Green=0, Blue=full, White=0
247 Blue (Red=0, Green=0, Blue=full, White=0)
Speed of the following effects can be controlled by the
Shutter/Strobe channel (DMX values of 96-127)
248 Rainbow effect (with fade time)
249 Rainbow effect
250-255 Zone effects
CH28 000-255 Zoom (8 bit)
Zoom from min. to max. beam angle
CH29 000-255 Zoom ne (16 bit)
Fine zooming from min. to max.
CH30
Shutter/Strobe
000-031 Shutter closed
032-063 Strobe effect from slow--> fast (zone 3 only)
064-095 Strobe effect from slow--> fast (All zones together)

9V1.0
Mode1 (32 CH) Value Function
Set value on Virtual colour wheel
096-111 Zone effects+rainbow effects speed control, slow--> fast
112-127 Zone effects+rainbow effects speed control, fast--> slow
/opposite direction/
128-143 Opening pulses in sequences from slow--> fast (All zones
together)
144-159 Closing pulses in sequences from fast--> slow (All zones
together)
160-175 Random strobe effect from slow--> fast (random zone)
176-191 Random strobe effect from slow--> fast (random zone +random
strobe)
192-223 Random strobe effect from slow --> fast (All zones together)
224-255 Shutter open
CH31 000-255 Dimmer (8 bit)
Dimmer intensity from 0% to 100%
CH32 000-255 Dimmer ne (16 bit)
Fine dimming
Mode 2 (16 CH) Value Function
CH1
Special functions
000-049 Reserved
050-179 Reserved
180-189 Zoom Reserved
190-255 Reserved
CH2 000-255 Red(8 bit)-all zones
Red LEDs saturation control (0-100%)
CH3 000-255 Red ne(16 bit) - all zones
Fine red LEDs saturation control
CH4 000-255 Green(8 bit)-all zones
Green LEDs saturation control (0-100%)
CH5 000-255 Green ne(16 bit) - all zones
Fine green LEDs saturation control
CH6 000-255 Blue(8 bit)-all zones
Blue LEDs saturation control (0-100%)
CH7 000-255 Blue ne(16 bit) - all zones
Fine blue LEDs saturation control
CH8 000-255 White(8 bit)-all zones
White LEDs saturation control (0-100%)
CH9 000-255 White ne(16 bit) - all zones
Fine White LEDs saturation control
CH10
Color temperature
000 No function
001-255 Colour temperature correction from 2000K to 2700K(menu item
“Colour Calibration Mode”=Off)
CH11
Virtual Colour Wheel
For detailed description see “ Virtual colour wheel- colour mixing
chart
000 No function
001-002 White 2700 K
003 White 2700 K (Halogen lamp mode*)
004-005 White 3200 K
006 White 3200 K (Halogen lamp mode*)

10 V1.0
Mode 2 (16 CH) Value Function
007-009 White 4200 K
010-012 White 5600 K
013-015 White 8000 K
016 Blue (Blue=full, Red+Green+White=0)
017-055 Red=0, Green->up,Blue =full, White=0
056 Light Blue (Red=0, Green=full, Blue =full, White=0)
057-095 Red=0, Green=full, Blue->down, White=0
096 Green (Red=0, Green=full, Blue =0, White=0)
097-134 Red->up, Green=full, Blue=0, White=0
135 Yellow (Red=full, Green=full, Blue=0, White=0)
136-174 Red=full, Green->down, Blue=0, White=0
175 Red(Red=full, Green=0, Blue=0, White=0)
176-214 Red=full, Green=0, Blue->up, White=0
215 Magenta (Red=full, Green=0, Blue=full, White=0)
216-246 Red -> down, Green=0, Blue=full, White=0
247 Blue (Red=0, Green=0, Blue=full, White=0)
Speed of the following effects can be controlled by the
Shutter/Strobe channel (DMX values of 96-127)
248 Rainbow effect (with fade time)
249 Rainbow effect
250-255 Zone effects
CH12 000-255 Zoom (8 bit)
Zoom from min. to max. beam angle
CH13 000-255 Zoom ne (16 bit)
Fine zooming from min. to max.
CH14
Shutter/Strobe
000-031 Shutter closed
032-063 Strobe effect from slow--> fast (zone 3 only)
064-095 Strobe effect from slow--> fast (All zones together)
Set value on Virtual colour wheel
096-111 Zone effects+rainbow effects speed control, slow--> fast
112-127 Zone effects+rainbow effects speed control, fast--> slow
/opposite direction/
128-143 Opening pulses in sequences from slow--> fast (All zones
together)
144-159 Closing pulses in sequences from fast--> slow (All zones
together)
160-175 Random strobe effect from slow--> fast (random zone)
176-191 Random strobe effect from slow--> fast (random zone +random
strobe)
192-223 Random strobe effect from slow --> fast (All zones together)
224-255 Shutter open
CH15 000-255 Dimmer (8 bit)
Dimmer intensity from 0% to 100%
CH16 000-255 Dimmer ne (16 bit)
Fine dimming
Mode 3 (10 CH) Value Function
CH1
Special functions
000-049 Reserved
050-179 Reserved
180-189 Zoom Reserved
Indice
Altri manuali Ovation Attrezzatura di illuminazione

Ovation
Ovation SPACE MINI PROFILE 40Z Manuale utente

Ovation
Ovation B-19 Manuale utente

Ovation
Ovation SPACE MINI FRESNEL 50T Manuale utente

Ovation
Ovation Min-E-10WW Manuale utente

Ovation
Ovation E-3 IP Manuale utente

Ovation
Ovation C19 Manuale utente

Ovation
Ovation PIONEER 200C ZOOM Manuale utente

Ovation
Ovation PIONEER 100C ZOOM Manuale utente

Ovation
Ovation Solar Panel 150T Manuale utente

Ovation
Ovation REVE P-3 IP Manuale utente