Owon SPE6053 Manuale utente

SPE series Single Channel
Output DC Power Supply
User Manual
For product support, visit : www.owon.com.hk/download

Mar. 2022 edition V1.0.1
Copyright © LILLIPUT Company. All rights reserved.
The LILLIPUT's products are under the protection of the patent rights,
including ones which have already obtained the patent rights and those which
are applying for. The information in this manual will replace all that in the
materials published originally.
The information in this manual was correct at the time of printing. However,
LILLIPUT will continue to improve products and reserves the rights to change
specification at any time without notice.
is the registered trademark of the LILLIPUT Company.
Fujian LILLIPUT Optoelectronics Technology Co., Ltd.
No. 19, Heming Road
Lantian Industrial Zone, Zhangzhou 363005 P.R. China
Tel: +86-596-2130430 Fax: +86-596-2109272
Web: www.owon.com E-mail: [email protected]

General Warranty
We warrant that the product will be free from defects in materials and
workmanship for a period of 2 years (1 year for accessories) from the date of
purchase of the product by the original purchaser from our company. This
warranty only applies to the original purchaser and is not transferable to a third
party.
If the product proves defective during the warranty period, we will either repair
the defective product without charge for parts and labour, or will provide a
replacement in exchange for the defective product. Parts, modules and
replacement products used by our company for warranty work may be new or
reconditioned like new. All replaced parts, modules and products become the
property of our company.
In order to obtain service under this warranty, the customer must notify our
company of the defect before the expiration of the warranty period. Customer
shall be responsible for packaging and shipping the defective product to the
designated service centre, a copy of the customers proof of purchase is also
required.
This warranty shall not apply to any defect, failure or damage caused by
improper use or improper or inadequate maintenance and care. We shall not
be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than our company representatives
to install, repair or service the product; b) to repair damage resulting from
improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of not our supplies; or d) to service a
product that has been modified or integrated with other products when the
effect of such modification or integration increases the time or difficulty of
servicing the product.
Please contact the nearest Sales and Service Offices for services.
Excepting the after-sales services provided in this summary or the
applicable warranty statements, we will not offer any guarantee for
maintenance definitely declared or hinted, including but not limited to
the implied guarantee for marketability and special-purpose acceptability.
We should not take any responsibilities for any indirect, special or
consequent damages.

i
Table of Contents
1. General Safety Requirements..................................................... 1
2. Safety Terms and Symbols.......................................................... 2
3. Quick Review............................................................................... 3
3.1 Panel and Interface ............................................................................................3
3.1.1 Front Panel...............................................................................................3
3.1.2 Rear Panel...............................................................................................5
3.1.3 User Interface...........................................................................................6
3.2 General Inspection .............................................................................................6
3.3 Power Inspection................................................................................................7
3.4 Output Inspection ...............................................................................................7
4. Panel Operation........................................................................... 9
4.1 Turn On/Off the Channel Output.........................................................................9
4.2 Set the Output Voltage/Current...........................................................................9
4.3 Over Voltage/Current Protection.........................................................................9
4.4 Memory key shortcut settings...........................................................................10
4.4.1 Quick output...........................................................................................10
4.4.2 Edit.........................................................................................................10
4.5 Set List Waveform Output.................................................................................11
4.5.1 List waveform editing..............................................................................11
4.5.2 List waveform output ..............................................................................12
4.6 Set Automatic Output at Power-on....................................................................13
4.7 Display.............................................................................................................13
5. Troubleshooting.......................................................................... 14
6.Appendix..................................................................................... 15
6.1 Appendix A:Accessories.................................................................................15
6.2 Appendix B: General Care and Cleaning ..........................................................15

1.General Safety Requirements
1
1. General Safety Requirements
Before use, please read the following safety precautions to avoid any
possible bodily injury and to prevent this product or any other connected
products from damage. To avoid any contingent danger, ensure this
product is only used within the ranges specified.
Only a qualified person should perform internal maintenance.
To avoid Fire or Personal Injury:
◼Use Proper Power Cord. Use only the power cord supplied with the
product and certified to use in your country.
◼Product Grounded. This instrument is grounded through the power cord
grounding conductor. To avoid electric shock, the grounding conductor
must be grounded. The product must be grounded properly before any
connection with its input or output terminals.
◼Check all Terminal Ratings. To avoid fire or shock hazard, check all
ratings and markings on this product. Refer to the user manual for more
information about ratings before connecting to the instrument.
◼Do not operate without covers. Do not operate the instrument with
covers or panels removed.
◼Use the Proper Fuse. Use only the specified type and rating fuse for this
instrument.
◼Avoid exposed circuit. Be careful when working on exposed circuitry to
avoid risk of electric shock or other injury.
◼Do not operate if any damage. If you suspect damage to the instrument,
have it inspected by qualified service personnel before further use.
◼Use your instrument in a well-ventilated area. Please keep well
ventilated and inspect the intake and fan regularly.
◼Do not operate in damp conditions. To avoid short circuiting to the
interior of the device or electric shock, please do not operate in a humid
environment.
◼Do not operate in an explosive atmosphere. To avoid damages to the
device or personal injuries, it is important to operate the device away from
an explosive atmosphere.
◼Keep product surfaces clean and dry. To avoid the influence of dust or
moisture in air, please keep the surface of device clean and dry.

2.Safety Terms and Symbols
2
2. Safety Terms and Symbols
Safety Terms
Terms in this manual (The following terms may appear in this manual):
Warning: Warning indicates conditions or practices that could result
in injury or loss of life.
Caution: Caution indicates the conditions or practices that could
result in damage to this product or other property.
Terms on the product. The following terms may appear on this product:
Danger: Indicates an immediate hazard or injury possibility.
Warning: Indicates a possible hazard or injury.
Caution: Indicates potential damage to the instrument or other property.
Safety Symbols
Symbols on the product. The following symbols may appear on the
product:
Hazardous Voltage
Refer to Manual
Protective Earth Terminal
Chassis Ground
Public Ground

3.Quick Review
3
3. Quick Review
3.1 Panel and Interface
3.1.1 Front Panel
1
11
10
9
8
3
6
7
2
5
4
Figure 3-1 Front Panel Overview
1
Display Area
Display user interface.
2
Current Key
Set current parameters, press to move the cursor when
editing parameters
3
Knob
Select the main menu or change the value, function
equals to the confirmation key.
4
Over Current
Setting Key
Set over current protection parameters, press to move
the cursor when editing parameters

3.Quick Review
4
5
Memory Key
5 sets of channel parameters can be stored for quick
output, or long press to enter the List waveform output
editing interface.
6
On/Off Key
Turn on/off the channel, or long press to turn on or turn
off the power-on automatic startup function.
7
Channel Output
Terminal
Output access of channel.
8
USP Port
USB charging port (no read/write function)
5V/1A charging (without U model);
Support QC2.0, QC3.0, BC1.2, Apple, Huawei FCP,
SamsungAFC quick charge protocol 5V, 9V quick
charge output, the maximum power is 12W, beyond the
maximum power will turn off the quick charge output
(only with U models).
9
Display Key
Number display and curve display switch key
10
Over Voltage
Setting Key
Set over voltage protection parameters, press to move
the cursor when editing parameters
11
Voltage Key
Set voltage parameters, press to move the cursor when
editing parameters
Button light instruction
On/Off key:The key lights up when the channel turns on.

3.Quick Review
5
3.1.2 Rear Panel
1
2
3
4
5
Figure 3-2 Rear Panel Overview
1
Air Vent
Air vent.
2
Power Button
Turn on/off the instrument.
3
Fuse
Power fuse.
4
AC Power Input
Jack
AC power input interface.
5
Device USB
Port
Update the firmware, PC software control port.

3.Quick Review
6
3.1.3 User Interface
Channel output status
Actual output power
Display cumulative
running time
CV: Constant Voltage output
CC: Constant Current output
Actual voltage output
Actual current output
Set values of voltage
Set values of current Set values of O.V.P
Set values of O.C.P
Figure 3-3 User Interface
3.2 General Inspection
After you get a new power supply, it is recommended that you should make a
check on the instrument according to the following steps:
1. Check whether there is any damage caused by transportation.
If it is found that the packaging carton or the foamed plastic protection
cushion has suffered serious damage, do not throw it away first till the
complete device and its accessories succeed in the electrical and
mechanical property tests.
2. Check the Accessories
The supplied accessories have been already described in the
"Appendix A: Enclosure" of this Manual. You can check whether there is
any loss of accessories with reference to this description. If it is found
that there is any accessory lost or damaged, please get in touch with
the distributor of our responsible for this service or our local offices.
3. Check the Complete Instrument
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Owon Alimentazione elettrica