>200LUX, the product will exit the semi-bright mode.
counterclockwise rotation is in the end, with the
maximum detection distance (nearly 16 meters radius).
Attention:when using the product, please adjust the
product sensitivity to the appropriate position, do not
adjust the product sensitivity to the maximum, to avoid
improper operation caused by wind starting curtains,
leaves, small animals, power grid and electrical
equipment, which may cause the product not to work
properly. When it is found that the product does not work
properly, the user can try to lower the sensitivity
appropriately before carrying out the test. Before or
during the installation of the product, if the functional test
is carried out, the personnel must leave the product
sensor area and do not walk around to prevent
continuous work of the sensor due to human movement.
can set the appropriate location according to their own
needs.
5.DIM setting knob:
DIM knob is responsible for managing standby
brightness Settings. Knob clockwise direction can set 4
levels of brightness. Users can set the appropriate
location according to their own needs.
Induction information
Detection angleDetection range(22℃)Height of installation2.5~4.5m
360°
16m
2m 2m
16m
Product Testing
You can manually adjust work latency, sensitivity, ,light
control values,D-TIME and DIM (for more information:
knob settings);It is very convenient to use.Sensor
suction Top Mounting height 2.5~4.5 m (Installation
details: Installation instructions), and wiring according
to the wiring diagram.Switch on the power supply,
about 1 minutes after the sensor into a stable working
state.Here, adjust the delay time to a minimum and
adjust the light control value to the sun for testing.If you
finished all testing, you can make time delay, light
control value and sensitivity settings according to your
needs, and the installation is complete.
Parameter setup Method: potentiometer
The following settings may require multiple
adjustments to meet your requirements.
Four detection ranges are:
1:2m 2:8m 3:10m 4:16m
When adjusting the knob clockwise, the
detection distance increases and the
detection distance decreases when the
knob is adjusted counterclockwise.The
detection distance is minimal (a radius
of nearly 2 meters) when the
(3)Detection distance setting (sensitivity)
2-16m
The standby time of the four gears is:
1:off 2:10min 3:20min 4. Automatic
semi-bright at night
When adjusting the knob clockwise,
standby time increases; Adjust the knob
counterclockwise to reduce standby
time.
Note: when the light control value
(3)D-TIME setting
(1)Light-control setting
The work illumination value can be
adjusted <10-2000LUX range.
Optical control value of four grades is:
1:<10LUX 2:<200LUX 3:<400LUX
4:Daytime
The working illumination value is about
10 LUX when the counterclockwise
rotation is in the end, and the working
<10-2000LUX
the shortest time should be chosen when adjusting the
detection range or walking test.
Note: After the lights turn off, it takes nearly 4 seconds for
it to sense again.The light will only light up when the
signal is detected at the end of this time.
Correct use of delay adjustment: It is used to adjust the
delay time of the sensor to detect the light after the body
moves and lights up to the automatic extinguishing
lamp.Users can adjust according to actual
requirements.Because the infrared induction products
have continuous sensing function, in short, the sensor in
the delay time before the end of any induction, the
system will be re-timed, as long as the person in the
detection range of activities, the lamp will not be
extinguished.Therefore, it is recommended that users
try to adjust the delay time to achieve energy saving.
(2)Delay setting
10sec-20min
The delay time of the four gears is:
1:10s 2:1min 3:6min 4:20min
The clockwise rotation increases while
the counterclockwise rotation
decreases. When adjusted to the
maximum, the delay time is 20 minutes.
When adjusted to a minimum, the delay
time is 10 seconds. It is suggested that
illumination value is about the day when the clockwise
spin is in the end.